diff --git a/.gitignore b/.gitignore index 1e0eebe..bc646a3 100644 --- a/.gitignore +++ b/.gitignore @@ -19,3 +19,5 @@ talos/controlplane.yaml talos/kubeconfig talos/talosconfig talos/worker.yaml +k8s/security/authentik-values.yaml +k8s/monitoring/alert-rules/alertmanager-discord.yml diff --git a/README.md b/README.md new file mode 100644 index 0000000..fba626b --- /dev/null +++ b/README.md @@ -0,0 +1,130 @@ +# Homelab Infrastructure + +Infrastructure-as-Code repository for my personal homelab and Kubernetes environment. + +This repository contains configuration files, monitoring stack definitions, alerting rules, Talos Linux cluster configuration, exporters, ingress resources and various infrastructure-related manifests used across my environment. + +## Main Technologies + +- Kubernetes +- Talos Linux +- Prometheus +- Grafana +- Alertmanager +- Blackbox Exporter +- SNMP Exporter +- IPMI Exporter +- Proxmox VE +- MetalLB +- Ingress NGINX +- Cloudflare Tunnel +- Ansible + +--- + +# Repository Structure + +## ansible/ + +Ansible playbooks and inventory files. + +Examples: +- package installation +- node-exporter deployment +- server automation + +--- + +## k8s/ + +Kubernetes manifests and infrastructure configuration. + +### cloudflare/ +Cloudflare Tunnel manifests. + +### homepage/ +Homepage dashboard manifests. + +### ingress-nginx/ +Ingress resources for exposed services. + +### longhorn/ +Longhorn distributed storage configuration. + +### metallb-system/ +MetalLB load balancer configuration. + +### monitoring/ +Monitoring stack configuration. + +Contains: +- Prometheus scrape configs +- exporter configs +- Prometheus alert rules +- Alertmanager Discord integration +- uptime-kuma config + +### others/ +Miscellaneous manifests. + +### security/ +Authentication and security-related configs. + +--- + +## talos/ + +Talos Linux cluster configuration. + +Contains: +- machine configs +- patches +- cluster bootstrap configs +- kubeconfig +- talosconfig + +--- + +# Monitoring Stack + +The monitoring stack includes: + +- Prometheus +- Grafana +- Alertmanager +- SNMP monitoring +- Blackbox ICMP monitoring +- IPMI monitoring +- Discord alerting + +Alerting covers: +- host availability +- interface utilization +- packet loss +- scrape failures +- CPU/RAM pressure +- Kubernetes health +- Proxmox monitoring + +--- + +# Goals + +Main goals of this homelab: + +- infrastructure automation +- observability +- Kubernetes learning +- monitoring and alerting +- network engineering +- high availability experiments +- infrastructure testing +- self-hosted services + +--- + +# Notes + +This repository intentionally excludes secrets and sensitive credentials using `.gitignore`. + +Some manifests may require environment-specific modifications before deployment. diff --git a/ansible/install-node-exporter.yml b/ansible/install-node-exporter.yml new file mode 100644 index 0000000..b98adbd --- /dev/null +++ b/ansible/install-node-exporter.yml @@ -0,0 +1,18 @@ +--- +- name: Install monitoring packages + hosts: monitoring_targets + become: true + + tasks: + - name: Install node exporter + ansible.builtin.apt: + name: + - prometheus-node-exporter + state: present + update_cache: true + + - name: Enable and start node exporter + ansible.builtin.systemd: + name: prometheus-node-exporter + enabled: true + state: started diff --git a/ansible/install-packages.yml b/ansible/install-packages.yml new file mode 100644 index 0000000..81d7c94 --- /dev/null +++ b/ansible/install-packages.yml @@ -0,0 +1,20 @@ +--- +- name: Install common packages + hosts: debian machines + become: true + + vars: + common_packages: + - qemu-guest-agent + - btop + - fastfetch + - curl + - wget + - nano + + tasks: + - name: Install packages + apt: + name: "{{ common_packages }}" + state: present + update_cache: true diff --git a/ansible/inventory.ini b/ansible/inventory.ini new file mode 100644 index 0000000..6fc58f7 --- /dev/null +++ b/ansible/inventory.ini @@ -0,0 +1,45 @@ +[machines] +proxmox ansible_host=10.0.2.5 +mc-servers ansible_host=10.0.3.2 +#backup-nas ansible_host=10.0.2.12 + +[debian] +plexisklo ansible_host=10.0.1.2 +synch ansible_host=10.0.1.3 +graylog ansible_host=10.0.1.4 +kozel-tajne ansible_host=10.0.1.6 +kozel-web ansible_host=10.0.1.7 +qbittorrent ansible_host=10.0.1.8 +docker ansible_host=10.0.1.9 +pihole ansible_host=10.0.1.10 +gitea ansible_host=10.0.1.11 ansible_port=2030 +mariadb ansible_host=10.0.1.12 +zabbix ansible_host=10.0.1.20 + +[k8s] +k8s-cp-00 ansible_host=10.0.4.2 +k8s-cp-01 ansible_host=10.0.4.3 +k8s-cp-02 ansible_host=10.0.4.4 +k8s-wrk-00 ansible_host=10.0.4.12 +k8s-wrk-01 ansible_host=10.0.4.13 +k8s-wrk-02 ansible_host=10.0.4.14 + +[all:vars] +ansible_user=root +ansible_port=22 +ansible_python_interpreter=/usr/bin/python3 + +[monitoring_targets] +proxmox +mc-servers +plexisklo +synch +graylog +kozel-tajne +kozel-web +qbittorrent +docker +pihole +gitea +mariadb +zabbix diff --git a/k8s/longhorn-system.json b/k8s/longhorn/longhorn-system.json similarity index 100% rename from k8s/longhorn-system.json rename to k8s/longhorn/longhorn-system.json diff --git a/k8s/longhorn-test.yaml b/k8s/longhorn/longhorn-test.yaml similarity index 100% rename from k8s/longhorn-test.yaml rename to k8s/longhorn/longhorn-test.yaml diff --git a/k8s/monitoring/alert-rules/blackbox.yml b/k8s/monitoring/alert-rules/blackbox.yml new file mode 100644 index 0000000..e14ea9e --- /dev/null +++ b/k8s/monitoring/alert-rules/blackbox.yml @@ -0,0 +1,30 @@ +apiVersion: monitoring.coreos.com/v1 +kind: PrometheusRule +metadata: + name: blackbox-alerts + namespace: monitoring + labels: + release: kube-prometheus-stack + +spec: + groups: + - name: blackbox + rules: + + - alert: DeviceDown + expr: probe_success == 0 + for: 1m + labels: + severity: critical + annotations: + summary: "Device down" + description: "{{ $labels.instance }} is DOWN" + + - alert: HighPing + expr: probe_duration_seconds > 0.5 + for: 2m + labels: + severity: warning + annotations: + summary: "High ping" + description: "{{ $labels.instance }} has high latency" diff --git a/k8s/monitoring/alert-rules/ipmi.yml b/k8s/monitoring/alert-rules/ipmi.yml new file mode 100644 index 0000000..27dfd25 --- /dev/null +++ b/k8s/monitoring/alert-rules/ipmi.yml @@ -0,0 +1,331 @@ +apiVersion: monitoring.coreos.com/v1 +kind: PrometheusRule +metadata: + name: ipmi-alerts + namespace: monitoring + labels: + release: kube-prometheus-stack + +spec: + groups: + - name: ipmi-targets + rules: + - alert: IPMITargetDown + expr: up{job=~"ipmi.*|.*ipmi.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "IPMI target down" + description: "{{ $labels.instance }} IPMI scrape target is down." + + - alert: IPMIExporterCollectorDown + expr: ipmi_up{job=~"ipmi.*|.*ipmi.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "IPMI collector down" + description: "{{ $labels.instance }} IPMI collector {{ $labels.collector }} is down." + + - alert: IPMIScrapeSlow + expr: scrape_duration_seconds{job=~"ipmi.*|.*ipmi.*"} > 30 + for: 5m + labels: + severity: warning + annotations: + summary: "IPMI scrape slow" + description: "{{ $labels.instance }} IPMI scrape takes more than 30 seconds." + + - alert: IPMIScrapeVerySlow + expr: scrape_duration_seconds{job=~"ipmi.*|.*ipmi.*"} > 90 + for: 2m + labels: + severity: critical + annotations: + summary: "IPMI scrape very slow" + description: "{{ $labels.instance }} IPMI scrape takes more than 90 seconds." + + - alert: IPMILowSamples + expr: scrape_samples_scraped{job=~"ipmi.*|.*ipmi.*"} < 10 + for: 10m + labels: + severity: warning + annotations: + summary: "IPMI low sample count" + description: "{{ $labels.instance }} IPMI scrape returns fewer than 10 samples." + + - name: ipmi-chassis + rules: + - alert: IPMIChassisPowerOff + expr: ipmi_chassis_power_state{job=~"ipmi.*|.*ipmi.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Server chassis power is off" + description: "{{ $labels.instance }} chassis power state is OFF." + + - alert: IPMIChassisCoolingFault + expr: ipmi_chassis_cooling_fault_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 2m + labels: + severity: critical + annotations: + summary: "Chassis cooling fault" + description: "{{ $labels.instance }} reports chassis cooling fault." + + - alert: IPMIChassisDriveFault + expr: ipmi_chassis_drive_fault_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 2m + labels: + severity: critical + annotations: + summary: "Chassis drive fault" + description: "{{ $labels.instance }} reports chassis drive fault." + + - alert: IPMIChassisPowerControlFault + expr: ipmi_chassis_power_control_fault_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 2m + labels: + severity: critical + annotations: + summary: "Power control fault" + description: "{{ $labels.instance }} reports power control fault." + + - name: ipmi-sensors + rules: + - alert: IPMISensorWarning + expr: ipmi_sensor_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "IPMI sensor warning" + description: "{{ $labels.instance }} sensor {{ $labels.name }} reports WARNING state." + + - alert: IPMISensorCritical + expr: ipmi_sensor_state{job=~"ipmi.*|.*ipmi.*"} >= 2 + for: 2m + labels: + severity: critical + annotations: + summary: "IPMI sensor critical" + description: "{{ $labels.instance }} sensor {{ $labels.name }} reports CRITICAL state." + + - alert: IPMISensorMissingValue + expr: ipmi_sensor_value{job=~"ipmi.*|.*ipmi.*"} != ipmi_sensor_value{job=~"ipmi.*|.*ipmi.*"} + for: 5m + labels: + severity: warning + annotations: + summary: "IPMI sensor value is NaN" + description: "{{ $labels.instance }} sensor {{ $labels.name }} returns NaN." + + - name: ipmi-fans + rules: + - alert: IPMIFanStateWarning + expr: ipmi_fan_speed_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "Fan warning state" + description: "{{ $labels.instance }} fan {{ $labels.name }} reports WARNING state." + + - alert: IPMIFanStateCritical + expr: ipmi_fan_speed_state{job=~"ipmi.*|.*ipmi.*"} >= 2 + for: 2m + labels: + severity: critical + annotations: + summary: "Fan critical state" + description: "{{ $labels.instance }} fan {{ $labels.name }} reports CRITICAL state." + + - alert: IPMIFanStopped + expr: ipmi_fan_speed_rpm{job=~"ipmi.*|.*ipmi.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Fan stopped" + description: "{{ $labels.instance }} fan {{ $labels.name }} reports 0 RPM." + + - alert: IPMIFanLowRPM + expr: ipmi_fan_speed_rpm{job=~"ipmi.*|.*ipmi.*"} > 0 and ipmi_fan_speed_rpm{job=~"ipmi.*|.*ipmi.*"} < 1000 + for: 5m + labels: + severity: warning + annotations: + summary: "Fan low RPM" + description: "{{ $labels.instance }} fan {{ $labels.name }} is below 1000 RPM." + + - alert: IPMIFanVeryHighRPM + expr: ipmi_fan_speed_rpm{job=~"ipmi.*|.*ipmi.*"} > 10000 + for: 10m + labels: + severity: warning + annotations: + summary: "Fan very high RPM" + description: "{{ $labels.instance }} fan {{ $labels.name }} is above 10000 RPM." + + - name: ipmi-temperature + rules: + - alert: IPMITemperatureHigh + expr: ipmi_temperature_celsius{job=~"ipmi.*|.*ipmi.*"} > 70 + for: 5m + labels: + severity: warning + annotations: + summary: "High IPMI temperature" + description: "{{ $labels.instance }} sensor {{ $labels.name }} is above 70°C." + + - alert: IPMITemperatureCritical + expr: ipmi_temperature_celsius{job=~"ipmi.*|.*ipmi.*"} > 85 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical IPMI temperature" + description: "{{ $labels.instance }} sensor {{ $labels.name }} is above 85°C." + + - alert: IPMISensorTemperatureHigh + expr: ipmi_sensor_value{type=~"Temperature|temperature",job=~"ipmi.*|.*ipmi.*"} > 70 + for: 5m + labels: + severity: warning + annotations: + summary: "High sensor temperature" + description: "{{ $labels.instance }} sensor {{ $labels.name }} is above 70°C." + + - alert: IPMISensorTemperatureCritical + expr: ipmi_sensor_value{type=~"Temperature|temperature",job=~"ipmi.*|.*ipmi.*"} > 85 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical sensor temperature" + description: "{{ $labels.instance }} sensor {{ $labels.name }} is above 85°C." + + - name: ipmi-power-current-voltage + rules: + - alert: IPMIPowerHigh + expr: ipmi_power_watts{job=~"ipmi.*|.*ipmi.*"} > 600 + for: 10m + labels: + severity: warning + annotations: + summary: "High power usage" + description: "{{ $labels.instance }} power usage is above 600 W." + + - alert: IPMIPowerVeryHigh + expr: ipmi_power_watts{job=~"ipmi.*|.*ipmi.*"} > 800 + for: 5m + labels: + severity: critical + annotations: + summary: "Very high power usage" + description: "{{ $labels.instance }} power usage is above 800 W." + + - alert: IPMIPowerStateWarning + expr: ipmi_power_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "Power sensor warning" + description: "{{ $labels.instance }} power sensor {{ $labels.name }} reports WARNING state." + + - alert: IPMIPowerStateCritical + expr: ipmi_power_state{job=~"ipmi.*|.*ipmi.*"} >= 2 + for: 2m + labels: + severity: critical + annotations: + summary: "Power sensor critical" + description: "{{ $labels.instance }} power sensor {{ $labels.name }} reports CRITICAL state." + + - alert: IPMICurrentStateWarning + expr: ipmi_current_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "Current sensor warning" + description: "{{ $labels.instance }} current sensor {{ $labels.name }} reports WARNING state." + + - alert: IPMICurrentStateCritical + expr: ipmi_current_state{job=~"ipmi.*|.*ipmi.*"} >= 2 + for: 2m + labels: + severity: critical + annotations: + summary: "Current sensor critical" + description: "{{ $labels.instance }} current sensor {{ $labels.name }} reports CRITICAL state." + + - alert: IPMIVoltageStateWarning + expr: ipmi_voltage_state{job=~"ipmi.*|.*ipmi.*"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "Voltage sensor warning" + description: "{{ $labels.instance }} voltage sensor {{ $labels.name }} reports WARNING state." + + - alert: IPMIVoltageStateCritical + expr: ipmi_voltage_state{job=~"ipmi.*|.*ipmi.*"} >= 2 + for: 2m + labels: + severity: critical + annotations: + summary: "Voltage sensor critical" + description: "{{ $labels.instance }} voltage sensor {{ $labels.name }} reports CRITICAL state." + + - name: ipmi-generic-thresholds + rules: + - alert: IPMISensorVoltageVeryLow + expr: ipmi_sensor_value{type=~"Voltage|voltage",job=~"ipmi.*|.*ipmi.*"} > 0 and ipmi_sensor_value{type=~"Voltage|voltage",job=~"ipmi.*|.*ipmi.*"} < 0.8 + for: 5m + labels: + severity: warning + annotations: + summary: "Voltage sensor very low" + description: "{{ $labels.instance }} voltage sensor {{ $labels.name }} is very low." + + - alert: IPMISensorVoltageVeryHigh + expr: ipmi_sensor_value{type=~"Voltage|voltage",job=~"ipmi.*|.*ipmi.*"} > 14 + for: 5m + labels: + severity: warning + annotations: + summary: "Voltage sensor very high" + description: "{{ $labels.instance }} voltage sensor {{ $labels.name }} is very high." + + - alert: IPMISensorCurrentHigh + expr: ipmi_current_amperes{job=~"ipmi.*|.*ipmi.*"} > 20 + for: 5m + labels: + severity: warning + annotations: + summary: "High current" + description: "{{ $labels.instance }} current sensor {{ $labels.name }} is above 20 A." + + - name: ipmi-bmc-info + rules: + - alert: IPMIBMCInfoMissing + expr: absent(ipmi_bmc_info{job=~"ipmi.*|.*ipmi.*"}) + for: 10m + labels: + severity: warning + annotations: + summary: "IPMI BMC info missing" + description: "No ipmi_bmc_info metrics are present." + + - alert: IPMIBMCFirmwareUnknown + expr: ipmi_bmc_info{firmware_revision="",job=~"ipmi.*|.*ipmi.*"} == 1 + for: 10m + labels: + severity: info + annotations: + summary: "BMC firmware revision unknown" + description: "{{ $labels.instance }} does not report BMC firmware revision." diff --git a/k8s/monitoring/alert-rules/node-exporter.yml b/k8s/monitoring/alert-rules/node-exporter.yml new file mode 100644 index 0000000..83c45f0 --- /dev/null +++ b/k8s/monitoring/alert-rules/node-exporter.yml @@ -0,0 +1,470 @@ +apiVersion: monitoring.coreos.com/v1 +kind: PrometheusRule +metadata: + name: node-exporter-alerts + namespace: monitoring + labels: + release: kube-prometheus-stack + +spec: + groups: + - name: node-exporter-availability + rules: + - alert: NodeDown + expr: up{job=~".*node.*|external-node-exporters"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Node down" + description: "{{ $labels.instance }} is down." + + - alert: NodeExporterMissing + expr: absent(up{job=~".*node.*|external-node-exporters"}) + for: 5m + labels: + severity: critical + annotations: + summary: "Node exporter missing" + description: "No node-exporter targets are currently being scraped." + + - name: node-exporter-cpu-load + rules: + - alert: NodeHighCPU + expr: 100 - (avg by(instance) (rate(node_cpu_seconds_total{mode="idle"}[5m])) * 100) > 85 + for: 10m + labels: + severity: warning + annotations: + summary: "High CPU usage" + description: "{{ $labels.instance }} CPU usage is above 85% for 10 minutes." + + - alert: NodeCriticalCPU + expr: 100 - (avg by(instance) (rate(node_cpu_seconds_total{mode="idle"}[5m])) * 100) > 95 + for: 5m + labels: + severity: critical + annotations: + summary: "Critical CPU usage" + description: "{{ $labels.instance }} CPU usage is above 95%." + + - alert: NodeHighLoad1 + expr: node_load1 / count by(instance) (node_cpu_seconds_total{mode="idle"}) > 2 + for: 5m + labels: + severity: warning + annotations: + summary: "High 1m load" + description: "{{ $labels.instance }} has high 1-minute load." + + - alert: NodeHighLoad5 + expr: node_load5 / count by(instance) (node_cpu_seconds_total{mode="idle"}) > 1.75 + for: 10m + labels: + severity: warning + annotations: + summary: "High 5m load" + description: "{{ $labels.instance }} has high 5-minute load." + + - alert: NodeHighLoad15 + expr: node_load15 / count by(instance) (node_cpu_seconds_total{mode="idle"}) > 1.5 + for: 15m + labels: + severity: warning + annotations: + summary: "High 15m load" + description: "{{ $labels.instance }} has high 15-minute load." + + - alert: NodeCriticalLoad15 + expr: node_load15 / count by(instance) (node_cpu_seconds_total{mode="idle"}) > 3 + for: 10m + labels: + severity: critical + annotations: + summary: "Critical 15m load" + description: "{{ $labels.instance }} has critically high 15-minute load." + + - name: node-exporter-memory-swap + rules: + - alert: NodeMemoryLow + expr: (node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes) < 0.10 + for: 10m + labels: + severity: warning + annotations: + summary: "Low available memory" + description: "{{ $labels.instance }} has less than 10% memory available." + + - alert: NodeMemoryCritical + expr: (node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes) < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Critical available memory" + description: "{{ $labels.instance }} has less than 5% memory available." + + - alert: NodeSwapHigh + expr: (node_memory_SwapTotal_bytes > 0) and ((node_memory_SwapTotal_bytes - node_memory_SwapFree_bytes) / node_memory_SwapTotal_bytes > 0.50) + for: 10m + labels: + severity: warning + annotations: + summary: "High swap usage" + description: "{{ $labels.instance }} swap usage is above 50%." + + - alert: NodeSwapCritical + expr: (node_memory_SwapTotal_bytes > 0) and ((node_memory_SwapTotal_bytes - node_memory_SwapFree_bytes) / node_memory_SwapTotal_bytes > 0.80) + for: 5m + labels: + severity: critical + annotations: + summary: "Critical swap usage" + description: "{{ $labels.instance }} swap usage is above 80%." + + - alert: NodeOOMKills + expr: increase(node_vmstat_oom_kill[10m]) > 0 + for: 1m + labels: + severity: critical + annotations: + summary: "OOM kill detected" + description: "{{ $labels.instance }} had OOM kill event in last 10 minutes." + + - name: node-exporter-filesystems + rules: + - alert: NodeRootFilesystemLow + expr: (node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs",mountpoint="/"} / node_filesystem_size_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs",mountpoint="/"}) < 0.15 + for: 10m + labels: + severity: warning + annotations: + summary: "Root filesystem low" + description: "{{ $labels.instance }} root filesystem has less than 15% free space." + + - alert: NodeRootFilesystemCritical + expr: (node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs",mountpoint="/"} / node_filesystem_size_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs",mountpoint="/"}) < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Root filesystem critical" + description: "{{ $labels.instance }} root filesystem has less than 5% free space." + + - alert: NodeFilesystemLow + expr: (node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"} / node_filesystem_size_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}) < 0.15 + for: 15m + labels: + severity: warning + annotations: + summary: "Filesystem low" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} has less than 15% free space." + + - alert: NodeFilesystemCritical + expr: (node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"} / node_filesystem_size_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}) < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Filesystem critical" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} has less than 5% free space." + + - alert: NodeFilesystemWillFillSoon + expr: predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}[6h], 24 * 3600) < 0 + for: 30m + labels: + severity: warning + annotations: + summary: "Filesystem will fill soon" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} is predicted to fill within 24 hours." + + - alert: NodeFilesystemWillFillVerySoon + expr: predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}[2h], 6 * 3600) < 0 + for: 15m + labels: + severity: critical + annotations: + summary: "Filesystem will fill very soon" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} is predicted to fill within 6 hours." + + - alert: NodeInodesLow + expr: (node_filesystem_files_free{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"} / node_filesystem_files{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}) < 0.10 + for: 15m + labels: + severity: warning + annotations: + summary: "Filesystem inodes low" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} has less than 10% free inodes." + + - alert: NodeInodesCritical + expr: (node_filesystem_files_free{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"} / node_filesystem_files{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"}) < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Filesystem inodes critical" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} has less than 5% free inodes." + + - alert: NodeFilesystemReadOnly + expr: node_filesystem_readonly{fstype!~"tmpfs|overlay|squashfs|nsfs|ramfs"} == 1 + for: 2m + labels: + severity: critical + annotations: + summary: "Filesystem read-only" + description: "{{ $labels.instance }} {{ $labels.mountpoint }} is read-only." + + - name: node-exporter-disk-io + rules: + - alert: NodeDiskIOHigh + expr: rate(node_disk_io_time_seconds_total{device!~"loop.*|ram.*|dm-.*"}[5m]) > 0.90 + for: 10m + labels: + severity: warning + annotations: + summary: "High disk I/O utilization" + description: "{{ $labels.instance }} disk {{ $labels.device }} I/O utilization is high." + + - alert: NodeDiskReadLatencyHigh + expr: rate(node_disk_read_time_seconds_total{device!~"loop.*|ram.*"}[5m]) / rate(node_disk_reads_completed_total{device!~"loop.*|ram.*"}[5m]) > 0.1 + for: 10m + labels: + severity: warning + annotations: + summary: "High disk read latency" + description: "{{ $labels.instance }} disk {{ $labels.device }} read latency is high." + + - alert: NodeDiskWriteLatencyHigh + expr: rate(node_disk_write_time_seconds_total{device!~"loop.*|ram.*"}[5m]) / rate(node_disk_writes_completed_total{device!~"loop.*|ram.*"}[5m]) > 0.1 + for: 10m + labels: + severity: warning + annotations: + summary: "High disk write latency" + description: "{{ $labels.instance }} disk {{ $labels.device }} write latency is high." + + - alert: NodeDiskReadErrorsOrWeirdness + expr: increase(node_disk_reads_completed_total{device!~"loop.*|ram.*"}[10m]) == 0 and rate(node_disk_read_time_seconds_total{device!~"loop.*|ram.*"}[10m]) > 0 + for: 10m + labels: + severity: warning + annotations: + summary: "Possible disk read issue" + description: "{{ $labels.instance }} disk {{ $labels.device }} reports read time without completed reads." + + - name: node-exporter-network + rules: + - alert: NodeNetworkReceiveErrors + expr: increase(node_network_receive_errs_total{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"}[10m]) > 10 + for: 2m + labels: + severity: warning + annotations: + summary: "Network RX errors" + description: "{{ $labels.instance }} interface {{ $labels.device }} has RX errors." + + - alert: NodeNetworkTransmitErrors + expr: increase(node_network_transmit_errs_total{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"}[10m]) > 10 + for: 2m + labels: + severity: warning + annotations: + summary: "Network TX errors" + description: "{{ $labels.instance }} interface {{ $labels.device }} has TX errors." + + - alert: NodeNetworkReceiveDrops + expr: increase(node_network_receive_drop_total{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"}[10m]) > 50 + for: 2m + labels: + severity: warning + annotations: + summary: "Network RX drops" + description: "{{ $labels.instance }} interface {{ $labels.device }} has RX drops." + + - alert: NodeNetworkTransmitDrops + expr: increase(node_network_transmit_drop_total{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"}[10m]) > 50 + for: 2m + labels: + severity: warning + annotations: + summary: "Network TX drops" + description: "{{ $labels.instance }} interface {{ $labels.device }} has TX drops." + + - alert: NodeNetworkInterfaceFlapping + expr: changes(node_network_up{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"}[10m]) > 2 + for: 1m + labels: + severity: warning + annotations: + summary: "Network interface flapping" + description: "{{ $labels.instance }} interface {{ $labels.device }} changed link state more than twice in 10 minutes." + + - alert: NodeNetworkInterfaceDown + expr: node_network_up{device!~"lo|veth.*|docker.*|br-.*|cni.*|flannel.*|calico.*"} == 0 + for: 5m + labels: + severity: warning + annotations: + summary: "Network interface down" + description: "{{ $labels.instance }} interface {{ $labels.device }} is down." + + - name: node-exporter-system-health + rules: + - alert: NodeRebooted + expr: time() - node_boot_time_seconds < 600 + for: 1m + labels: + severity: info + annotations: + summary: "Node recently rebooted" + description: "{{ $labels.instance }} rebooted less than 10 minutes ago." + + - alert: NodeTimeDrift + expr: abs(node_timex_offset_seconds) > 0.1 + for: 5m + labels: + severity: warning + annotations: + summary: "Node time drift" + description: "{{ $labels.instance }} has time drift greater than 100 ms." + + - alert: NodeTimeDriftCritical + expr: abs(node_timex_offset_seconds) > 1 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical node time drift" + description: "{{ $labels.instance }} has time drift greater than 1 second." + + - alert: NodeClockNotSynchronized + expr: node_timex_sync_status == 0 + for: 5m + labels: + severity: warning + annotations: + summary: "Clock not synchronized" + description: "{{ $labels.instance }} clock is not synchronized." + + - alert: NodeEntropyLow + expr: node_entropy_available_bits < 256 + for: 10m + labels: + severity: warning + annotations: + summary: "Low entropy" + description: "{{ $labels.instance }} has low available entropy." + + - alert: NodeFileDescriptorsHigh + expr: node_filefd_allocated / node_filefd_maximum > 0.80 + for: 10m + labels: + severity: warning + annotations: + summary: "High file descriptor usage" + description: "{{ $labels.instance }} file descriptor usage is above 80%." + + - alert: NodeFileDescriptorsCritical + expr: node_filefd_allocated / node_filefd_maximum > 0.95 + for: 5m + labels: + severity: critical + annotations: + summary: "Critical file descriptor usage" + description: "{{ $labels.instance }} file descriptor usage is above 95%." + + - alert: NodeProcessesHigh + expr: node_procs_running > 300 + for: 10m + labels: + severity: warning + annotations: + summary: "High running process count" + description: "{{ $labels.instance }} has more than 300 running processes." + + - alert: NodeProcessesBlocked + expr: node_procs_blocked > 5 + for: 5m + labels: + severity: warning + annotations: + summary: "Blocked processes" + description: "{{ $labels.instance }} has more than 5 blocked processes." + + - name: node-exporter-systemd + rules: + - alert: NodeSystemdUnitFailed + expr: node_systemd_unit_state{state="failed"} == 1 + for: 5m + labels: + severity: warning + annotations: + summary: "Systemd unit failed" + description: "{{ $labels.instance }} systemd unit {{ $labels.name }} is failed." + + - alert: NodeSystemdServiceRestartingTooOften + expr: increase(node_systemd_service_restart_total[15m]) > 3 + for: 1m + labels: + severity: warning + annotations: + summary: "Systemd service restarting too often" + description: "{{ $labels.instance }} systemd service {{ $labels.name }} restarted more than 3 times in 15 minutes." + + - name: node-exporter-hardware + rules: + - alert: NodeTemperatureHigh + expr: node_hwmon_temp_celsius > 80 + for: 5m + labels: + severity: warning + annotations: + summary: "High hardware temperature" + description: "{{ $labels.instance }} sensor {{ $labels.chip }} {{ $labels.sensor }} is above 80°C." + + - alert: NodeTemperatureCritical + expr: node_hwmon_temp_celsius > 90 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical hardware temperature" + description: "{{ $labels.instance }} sensor {{ $labels.chip }} {{ $labels.sensor }} is above 90°C." + + - alert: NodeThermalZoneHigh + expr: node_thermal_zone_temp > 80000 + for: 5m + labels: + severity: warning + annotations: + summary: "High thermal zone temperature" + description: "{{ $labels.instance }} thermal zone {{ $labels.zone }} is above 80°C." + + - alert: NodeThermalZoneCritical + expr: node_thermal_zone_temp > 90000 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical thermal zone temperature" + description: "{{ $labels.instance }} thermal zone {{ $labels.zone }} is above 90°C." + + - name: node-exporter-prometheus-scrape + rules: + - alert: NodeExporterScrapeSlow + expr: scrape_duration_seconds{job=~".*node.*|external-node-exporters"} > 10 + for: 10m + labels: + severity: warning + annotations: + summary: "Node exporter scrape slow" + description: "Scrape of {{ $labels.instance }} takes more than 10 seconds." + + - alert: NodeExporterLowSamples + expr: scrape_samples_scraped{job=~".*node.*|external-node-exporters"} < 100 + for: 10m + labels: + severity: warning + annotations: + summary: "Node exporter low sample count" + description: "{{ $labels.instance }} returns fewer than 100 samples." diff --git a/k8s/monitoring/alert-rules/proxmox.yml b/k8s/monitoring/alert-rules/proxmox.yml new file mode 100644 index 0000000..3ee2069 --- /dev/null +++ b/k8s/monitoring/alert-rules/proxmox.yml @@ -0,0 +1,423 @@ +apiVersion: monitoring.coreos.com/v1 +kind: PrometheusRule +metadata: + name: proxmox-alerts + namespace: monitoring + labels: + release: kube-prometheus-stack + +spec: + groups: + - name: proxmox-targets + rules: + - alert: ProxmoxTargetDown + expr: up{job=~"proxmox.*|.*pve.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Proxmox exporter target down" + description: "{{ $labels.instance }} Proxmox/PVE scrape is down." + + - alert: ProxmoxScrapeSlow + expr: scrape_duration_seconds{job=~"proxmox.*|.*pve.*"} > 20 + for: 5m + labels: + severity: warning + annotations: + summary: "Proxmox scrape slow" + description: "{{ $labels.instance }} Proxmox scrape takes more than 20 seconds." + + - alert: ProxmoxScrapeVerySlow + expr: scrape_duration_seconds{job=~"proxmox.*|.*pve.*"} > 60 + for: 2m + labels: + severity: critical + annotations: + summary: "Proxmox scrape very slow" + description: "{{ $labels.instance }} Proxmox scrape takes more than 60 seconds." + + - alert: ProxmoxLowSamples + expr: scrape_samples_scraped{job=~"proxmox.*|.*pve.*"} < 20 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox low sample count" + description: "{{ $labels.instance }} Proxmox scrape returns fewer than 20 samples." + + - name: proxmox-nodes + rules: + - alert: ProxmoxNodeDown + expr: pve_node_status == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Proxmox node down" + description: "Proxmox node {{ $labels.node }} is down." + + - alert: ProxmoxNodeHighCPU + expr: pve_node_cpu_usage_ratio > 0.85 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox node high CPU" + description: "Node {{ $labels.node }} CPU usage is above 85%." + + - alert: ProxmoxNodeCriticalCPU + expr: pve_node_cpu_usage_ratio > 0.95 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox node critical CPU" + description: "Node {{ $labels.node }} CPU usage is above 95%." + + - alert: ProxmoxNodeHighMemory + expr: pve_node_memory_usage_bytes / pve_node_memory_size_bytes > 0.90 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox node high memory" + description: "Node {{ $labels.node }} memory usage is above 90%." + + - alert: ProxmoxNodeCriticalMemory + expr: pve_node_memory_usage_bytes / pve_node_memory_size_bytes > 0.97 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox node critical memory" + description: "Node {{ $labels.node }} memory usage is above 97%." + + - alert: ProxmoxNodeLowFreeMemory + expr: pve_node_memory_free_bytes / pve_node_memory_size_bytes < 0.10 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox node low free memory" + description: "Node {{ $labels.node }} has less than 10% free memory." + + - alert: ProxmoxNodeVeryLowFreeMemory + expr: pve_node_memory_free_bytes / pve_node_memory_size_bytes < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox node very low free memory" + description: "Node {{ $labels.node }} has less than 5% free memory." + + - alert: ProxmoxNodeHighLoad + expr: pve_node_loadavg_15 / pve_node_cpu_count > 1.5 + for: 15m + labels: + severity: warning + annotations: + summary: "Proxmox node high load" + description: "Node {{ $labels.node }} has high 15m load." + + - alert: ProxmoxNodeCriticalLoad + expr: pve_node_loadavg_15 / pve_node_cpu_count > 3 + for: 10m + labels: + severity: critical + annotations: + summary: "Proxmox node critical load" + description: "Node {{ $labels.node }} has critically high 15m load." + + - alert: ProxmoxNodeUptimeTooLow + expr: pve_node_uptime_seconds < 600 + for: 1m + labels: + severity: info + annotations: + summary: "Proxmox node recently rebooted" + description: "Node {{ $labels.node }} uptime is less than 10 minutes." + + - name: proxmox-guests + rules: + - alert: ProxmoxGuestDown + expr: pve_guest_status == 0 + for: 5m + labels: + severity: warning + annotations: + summary: "Proxmox guest down" + description: "Guest {{ $labels.id }} {{ $labels.name }} on node {{ $labels.node }} is down." + + - alert: ProxmoxGuestHighCPU + expr: pve_guest_cpu_usage_ratio > 0.90 + for: 15m + labels: + severity: warning + annotations: + summary: "Proxmox guest high CPU" + description: "Guest {{ $labels.id }} {{ $labels.name }} CPU usage is above 90%." + + - alert: ProxmoxGuestCriticalCPU + expr: pve_guest_cpu_usage_ratio > 0.98 + for: 10m + labels: + severity: critical + annotations: + summary: "Proxmox guest critical CPU" + description: "Guest {{ $labels.id }} {{ $labels.name }} CPU usage is above 98%." + + - alert: ProxmoxGuestHighMemory + expr: pve_guest_memory_usage_bytes / pve_guest_memory_size_bytes > 0.90 + for: 15m + labels: + severity: warning + annotations: + summary: "Proxmox guest high memory" + description: "Guest {{ $labels.id }} {{ $labels.name }} memory usage is above 90%." + + - alert: ProxmoxGuestCriticalMemory + expr: pve_guest_memory_usage_bytes / pve_guest_memory_size_bytes > 0.97 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox guest critical memory" + description: "Guest {{ $labels.id }} {{ $labels.name }} memory usage is above 97%." + + - alert: ProxmoxGuestLowFreeMemory + expr: pve_guest_memory_free_bytes / pve_guest_memory_size_bytes < 0.10 + for: 15m + labels: + severity: warning + annotations: + summary: "Proxmox guest low free memory" + description: "Guest {{ $labels.id }} {{ $labels.name }} has less than 10% free memory." + + - alert: ProxmoxGuestVeryLowFreeMemory + expr: pve_guest_memory_free_bytes / pve_guest_memory_size_bytes < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox guest very low free memory" + description: "Guest {{ $labels.id }} {{ $labels.name }} has less than 5% free memory." + + - alert: ProxmoxGuestHighDiskUsage + expr: pve_guest_disk_usage_bytes / pve_guest_disk_size_bytes > 0.85 + for: 15m + labels: + severity: warning + annotations: + summary: "Proxmox guest disk high usage" + description: "Guest {{ $labels.id }} {{ $labels.name }} disk usage is above 85%." + + - alert: ProxmoxGuestCriticalDiskUsage + expr: pve_guest_disk_usage_bytes / pve_guest_disk_size_bytes > 0.95 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox guest disk critical usage" + description: "Guest {{ $labels.id }} {{ $labels.name }} disk usage is above 95%." + + - alert: ProxmoxGuestUnexpectedlyRunning + expr: pve_guest_status == 1 and on(id) pve_guest_template == 1 + for: 10m + labels: + severity: info + annotations: + summary: "Proxmox template seems running" + description: "Template guest {{ $labels.id }} {{ $labels.name }} appears to be running." + + - alert: ProxmoxGuestRecentlyRebooted + expr: pve_guest_uptime_seconds > 0 and pve_guest_uptime_seconds < 600 + for: 1m + labels: + severity: info + annotations: + summary: "Proxmox guest recently rebooted" + description: "Guest {{ $labels.id }} {{ $labels.name }} uptime is less than 10 minutes." + + - name: proxmox-storage + rules: + - alert: ProxmoxStorageHighUsage + expr: pve_storage_usage_bytes / pve_storage_size_bytes > 0.85 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox storage high usage" + description: "Storage {{ $labels.storage }} on node {{ $labels.node }} is above 85%." + + - alert: ProxmoxStorageCriticalUsage + expr: pve_storage_usage_bytes / pve_storage_size_bytes > 0.95 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox storage critical usage" + description: "Storage {{ $labels.storage }} on node {{ $labels.node }} is above 95%." + + - alert: ProxmoxStorageLowFree + expr: pve_storage_free_bytes / pve_storage_size_bytes < 0.15 + for: 10m + labels: + severity: warning + annotations: + summary: "Proxmox storage low free" + description: "Storage {{ $labels.storage }} on node {{ $labels.node }} has less than 15% free space." + + - alert: ProxmoxStorageVeryLowFree + expr: pve_storage_free_bytes / pve_storage_size_bytes < 0.05 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox storage very low free" + description: "Storage {{ $labels.storage }} on node {{ $labels.node }} has less than 5% free space." + + - alert: ProxmoxStorageDisabled + expr: pve_storage_status == 0 + for: 5m + labels: + severity: warning + annotations: + summary: "Proxmox storage disabled/unavailable" + description: "Storage {{ $labels.storage }} on node {{ $labels.node }} is disabled or unavailable." + + - name: proxmox-cluster + rules: + - alert: ProxmoxClusterQuorumLost + expr: pve_cluster_quorate == 0 + for: 1m + labels: + severity: critical + annotations: + summary: "Proxmox cluster quorum lost" + description: "Proxmox cluster has lost quorum." + + - alert: ProxmoxClusterNodeOffline + expr: pve_cluster_node_online == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "Proxmox cluster node offline" + description: "Cluster node {{ $labels.node }} is offline." + + - alert: ProxmoxClusterExpectedVotesLow + expr: pve_cluster_expected_votes < 2 + for: 10m + labels: + severity: info + annotations: + summary: "Proxmox cluster expected votes low" + description: "Proxmox cluster expected votes is below 2." + + - name: proxmox-backups + rules: + - alert: ProxmoxBackupFailed + expr: pve_guest_backup_last_status == 0 + for: 10m + labels: + severity: critical + annotations: + summary: "Proxmox backup failed" + description: "Backup for guest {{ $labels.id }} {{ $labels.name }} failed." + + - alert: ProxmoxBackupTooOld + expr: time() - pve_guest_backup_last_timestamp_seconds > 7 * 24 * 3600 + for: 1h + labels: + severity: warning + annotations: + summary: "Proxmox backup too old" + description: "Backup for guest {{ $labels.id }} {{ $labels.name }} is older than 7 days." + + - alert: ProxmoxNoRecentBackup + expr: absent(pve_guest_backup_last_timestamp_seconds) + for: 1h + labels: + severity: warning + annotations: + summary: "No Proxmox backup metric found" + description: "No Proxmox backup timestamp metrics are present." + + - name: proxmox-replication-ha + rules: + - alert: ProxmoxReplicationFailed + expr: pve_replication_status == 0 + for: 10m + labels: + severity: critical + annotations: + summary: "Proxmox replication failed" + description: "Replication job {{ $labels.job }} on node {{ $labels.node }} failed." + + - alert: ProxmoxReplicationTooOld + expr: time() - pve_replication_last_sync_timestamp_seconds > 6 * 3600 + for: 30m + labels: + severity: warning + annotations: + summary: "Proxmox replication too old" + description: "Replication job {{ $labels.job }} last sync is older than 6 hours." + + - alert: ProxmoxHAServiceError + expr: pve_ha_service_status == 0 + for: 5m + labels: + severity: critical + annotations: + summary: "Proxmox HA service error" + description: "HA service {{ $labels.sid }} is not healthy." + + - name: proxmox-tasks + rules: + - alert: ProxmoxTaskFailed + expr: increase(pve_tasks_failed_total[30m]) > 0 + for: 1m + labels: + severity: warning + annotations: + summary: "Proxmox task failed" + description: "A Proxmox task failed on {{ $labels.instance }}." + + - alert: ProxmoxTasksFailingOften + expr: increase(pve_tasks_failed_total[6h]) > 5 + for: 10m + labels: + severity: critical + annotations: + summary: "Proxmox tasks failing often" + description: "More than 5 Proxmox tasks failed in 6 hours on {{ $labels.instance }}." + + - name: proxmox-exporter-health + rules: + - alert: ProxmoxExporterNoNodeMetrics + expr: absent(pve_node_status) + for: 10m + labels: + severity: critical + annotations: + summary: "No Proxmox node metrics" + description: "PVE exporter is not returning node metrics." + + - alert: ProxmoxExporterNoGuestMetrics + expr: absent(pve_guest_status) + for: 10m + labels: + severity: warning + annotations: + summary: "No Proxmox guest metrics" + description: "PVE exporter is not returning guest metrics." + + - alert: ProxmoxExporterNoStorageMetrics + expr: absent(pve_storage_size_bytes) + for: 10m + labels: + severity: warning + annotations: + summary: "No Proxmox storage metrics" + description: "PVE exporter is not returning storage metrics." diff --git a/k8s/monitoring/alert-rules/snmp.yml b/k8s/monitoring/alert-rules/snmp.yml new file mode 100644 index 0000000..349b24a --- /dev/null +++ b/k8s/monitoring/alert-rules/snmp.yml @@ -0,0 +1,211 @@ +apiVersion: monitoring.coreos.com/v1 +kind: PrometheusRule +metadata: + name: snmp-alerts + namespace: monitoring + labels: + release: kube-prometheus-stack + +spec: + groups: + - name: snmp-targets + rules: + - alert: SNMPTargetDown + expr: up{job=~"snmp.*"} == 0 + for: 2m + labels: + severity: critical + annotations: + summary: "SNMP target down" + description: "SNMP target {{ $labels.instance }} in job {{ $labels.job }} is down." + + - alert: SNMPScrapeSlow + expr: scrape_duration_seconds{job=~"snmp.*"} > 20 + for: 5m + labels: + severity: warning + annotations: + summary: "SNMP scrape is slow" + description: "SNMP scrape for {{ $labels.instance }} in job {{ $labels.job }} takes more than 20 seconds." + + - alert: SNMPScrapeVerySlow + expr: scrape_duration_seconds{job=~"snmp.*"} > 60 + for: 2m + labels: + severity: critical + annotations: + summary: "SNMP scrape is very slow" + description: "SNMP scrape for {{ $labels.instance }} in job {{ $labels.job }} takes more than 60 seconds." + + - alert: SNMPLowSamples + expr: scrape_samples_scraped{job=~"snmp.*"} < 5 + for: 10m + labels: + severity: warning + annotations: + summary: "SNMP scrape returns very few samples" + description: "SNMP target {{ $labels.instance }} in job {{ $labels.job }} returns fewer than 5 samples." + + - name: snmp-interfaces + rules: + - alert: InterfaceAdminUpButDown + expr: ifAdminStatus{job=~"snmp.*"} == 1 and ifOperStatus{job=~"snmp.*"} == 2 + for: 2m + labels: + severity: critical + annotations: + summary: "Interface admin up but operationally down" + description: "{{ $labels.instance }} {{ $labels.ifName }} is enabled but operationally down." + + - alert: InterfaceDown + expr: ifOperStatus{job=~"snmp.*"} == 2 + for: 5m + labels: + severity: warning + annotations: + summary: "Interface down" + description: "{{ $labels.instance }} {{ $labels.ifName }} is down." + + - alert: InterfaceHighRXUtilization + expr: ((rate(ifHCInOctets{job=~"snmp.*"}[5m]) * 8) / (ifHighSpeed{job=~"snmp.*"} * 1000000)) > 0.80 + for: 5m + labels: + severity: warning + annotations: + summary: "High RX interface utilization" + description: "{{ $labels.instance }} {{ $labels.ifName }} RX utilization is above 80%." + + - alert: InterfaceHighTXUtilization + expr: ((rate(ifHCOutOctets{job=~"snmp.*"}[5m]) * 8) / (ifHighSpeed{job=~"snmp.*"} * 1000000)) > 0.80 + for: 5m + labels: + severity: warning + annotations: + summary: "High TX interface utilization" + description: "{{ $labels.instance }} {{ $labels.ifName }} TX utilization is above 80%." + + - alert: InterfaceCriticalRXUtilization + expr: ((rate(ifHCInOctets{job=~"snmp.*"}[5m]) * 8) / (ifHighSpeed{job=~"snmp.*"} * 1000000)) > 0.95 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical RX interface utilization" + description: "{{ $labels.instance }} {{ $labels.ifName }} RX utilization is above 95%." + + - alert: InterfaceCriticalTXUtilization + expr: ((rate(ifHCOutOctets{job=~"snmp.*"}[5m]) * 8) / (ifHighSpeed{job=~"snmp.*"} * 1000000)) > 0.95 + for: 2m + labels: + severity: critical + annotations: + summary: "Critical TX interface utilization" + description: "{{ $labels.instance }} {{ $labels.ifName }} TX utilization is above 95%." + + - alert: InterfaceHighRXFixedThreshold + expr: (rate(ifHCInOctets{job=~"snmp.*"}[5m]) * 8) > 800000000 + for: 5m + labels: + severity: warning + annotations: + summary: "High RX traffic" + description: "{{ $labels.instance }} {{ $labels.ifName }} RX traffic is above 800 Mbit/s." + + - alert: InterfaceHighTXFixedThreshold + expr: (rate(ifHCOutOctets{job=~"snmp.*"}[5m]) * 8) > 800000000 + for: 5m + labels: + severity: warning + annotations: + summary: "High TX traffic" + description: "{{ $labels.instance }} {{ $labels.ifName }} TX traffic is above 800 Mbit/s." + + - alert: InterfaceRXErrors + expr: increase(ifInErrors{job=~"snmp.*"}[10m]) > 10 + for: 2m + labels: + severity: warning + annotations: + summary: "Interface RX errors" + description: "{{ $labels.instance }} {{ $labels.ifName }} has more than 10 RX errors in 10 minutes." + + - alert: InterfaceTXErrors + expr: increase(ifOutErrors{job=~"snmp.*"}[10m]) > 10 + for: 2m + labels: + severity: warning + annotations: + summary: "Interface TX errors" + description: "{{ $labels.instance }} {{ $labels.ifName }} has more than 10 TX errors in 10 minutes." + + - alert: InterfaceRXDiscards + expr: increase(ifInDiscards{job=~"snmp.*"}[10m]) > 50 + for: 2m + labels: + severity: warning + annotations: + summary: "Interface RX discards" + description: "{{ $labels.instance }} {{ $labels.ifName }} has more than 50 RX discards in 10 minutes." + + - alert: InterfaceTXDiscards + expr: increase(ifOutDiscards{job=~"snmp.*"}[10m]) > 50 + for: 2m + labels: + severity: warning + annotations: + summary: "Interface TX discards" + description: "{{ $labels.instance }} {{ $labels.ifName }} has more than 50 TX discards in 10 minutes." + + - alert: InterfaceBroadcastStorm + expr: increase(ifHCInBroadcastPkts{job=~"snmp.*"}[5m]) > 10000 + for: 2m + labels: + severity: warning + annotations: + summary: "Possible broadcast storm" + description: "{{ $labels.instance }} {{ $labels.ifName }} received more than 10000 broadcast packets in 5 minutes." + + - alert: InterfaceMulticastStorm + expr: increase(ifHCInMulticastPkts{job=~"snmp.*"}[5m]) > 50000 + for: 2m + labels: + severity: warning + annotations: + summary: "Possible multicast storm" + description: "{{ $labels.instance }} {{ $labels.ifName }} received more than 50000 multicast packets in 5 minutes." + + - alert: InterfaceNoTraffic + expr: rate(ifHCInOctets{job=~"snmp.*"}[30m]) == 0 and rate(ifHCOutOctets{job=~"snmp.*"}[30m]) == 0 and ifOperStatus{job=~"snmp.*"} == 1 + for: 30m + labels: + severity: info + annotations: + summary: "Interface has no traffic" + description: "{{ $labels.instance }} {{ $labels.ifName }} is up but has no RX/TX traffic for 30 minutes." + + - alert: InterfaceCounterReset + expr: resets(ifHCInOctets{job=~"snmp.*"}[15m]) > 0 or resets(ifHCOutOctets{job=~"snmp.*"}[15m]) > 0 + for: 1m + labels: + severity: info + annotations: + summary: "Interface counter reset" + description: "{{ $labels.instance }} {{ $labels.ifName }} interface counter reset detected." + + - alert: InterfaceSpeedUnknown + expr: ifHighSpeed{job=~"snmp.*"} == 0 + for: 10m + labels: + severity: info + annotations: + summary: "Interface speed unknown" + description: "{{ $labels.instance }} {{ $labels.ifName }} reports unknown interface speed." + + - alert: InterfacePossibleFlapping + expr: changes(ifOperStatus{job=~"snmp.*"}[10m]) > 2 + for: 1m + labels: + severity: warning + annotations: + summary: "Possible interface flapping" + description: "{{ $labels.instance }} {{ $labels.ifName }} changed operational state more than twice in 10 minutes." diff --git a/k8s/monitoring/prometheus-exporters-configs/blackbox-redfish-values.yml b/k8s/monitoring/prometheus-exporters-configs/blackbox-redfish-values.yml new file mode 100644 index 0000000..440e2f6 --- /dev/null +++ b/k8s/monitoring/prometheus-exporters-configs/blackbox-redfish-values.yml @@ -0,0 +1,12 @@ +config: + modules: + redfish: + prober: http + timeout: 10s + http: + method: GET + + tls_config: + insecure_skip_verify: true + + preferred_ip_protocol: ip4 \ No newline at end of file diff --git a/k8s/monitoring/prometheus-exporters-configs/blackbox-values.yaml b/k8s/monitoring/prometheus-exporters-configs/blackbox-values.yaml new file mode 100644 index 0000000..c6c3b42 --- /dev/null +++ b/k8s/monitoring/prometheus-exporters-configs/blackbox-values.yaml @@ -0,0 +1,13 @@ +config: + modules: + icmp: + prober: icmp + timeout: 5s + icmp: + preferred_ip_protocol: ip4 + + http_2xx: + prober: http + timeout: 5s + http: + preferred_ip_protocol: ip4 diff --git a/k8s/monitoring/prometheus-exporters-configs/pve-exporter.yaml b/k8s/monitoring/prometheus-exporters-configs/pve-exporter.yaml new file mode 100644 index 0000000..3bb0e7a --- /dev/null +++ b/k8s/monitoring/prometheus-exporters-configs/pve-exporter.yaml @@ -0,0 +1,36 @@ +apiVersion: apps/v1 +kind: Deployment +metadata: + name: pve-exporter + namespace: monitoring +spec: + replicas: 1 + selector: + matchLabels: + app: pve-exporter + template: + metadata: + labels: + app: pve-exporter + spec: + containers: + - name: pve-exporter + image: prompve/prometheus-pve-exporter:latest + ports: + - containerPort: 9221 + envFrom: + - secretRef: + name: pve-exporter-secret +--- +apiVersion: v1 +kind: Service +metadata: + name: pve-exporter + namespace: monitoring +spec: + selector: + app: pve-exporter + ports: + - name: http + port: 9221 + targetPort: 9221 diff --git a/k8s/monitoring/prometheus-exporters-configs/snmp-exporter-manual.yaml b/k8s/monitoring/prometheus-exporters-configs/snmp-exporter-manual.yaml new file mode 100644 index 0000000..e1b942a --- /dev/null +++ b/k8s/monitoring/prometheus-exporters-configs/snmp-exporter-manual.yaml @@ -0,0 +1,44 @@ +apiVersion: apps/v1 +kind: Deployment +metadata: + name: snmp-exporter-manual + namespace: monitoring +spec: + replicas: 1 + selector: + matchLabels: + app: snmp-exporter-manual + template: + metadata: + labels: + app: snmp-exporter-manual + spec: + containers: + - name: snmp-exporter + image: quay.io/prometheus/snmp-exporter:v0.30.1 + args: + - --config.file=/etc/snmp_exporter/snmp.yml + ports: + - name: http + containerPort: 9116 + volumeMounts: + - name: snmp-config + mountPath: /etc/snmp_exporter/snmp.yml + subPath: snmp.yml + volumes: + - name: snmp-config + configMap: + name: snmp-exporter-config +--- +apiVersion: v1 +kind: Service +metadata: + name: snmp-exporter-manual + namespace: monitoring +spec: + selector: + app: snmp-exporter-manual + ports: + - name: http + port: 9116 + targetPort: 9116 diff --git a/k8s/monitoring/prometheus-exporters-configs/snmp-values.yaml b/k8s/monitoring/prometheus-exporters-configs/snmp-values.yaml new file mode 100644 index 0000000..471d6e2 --- /dev/null +++ b/k8s/monitoring/prometheus-exporters-configs/snmp-values.yaml @@ -0,0 +1,20288 @@ + auths: + public_v2: + community: public + version: 2 + modules: + resources_hst: + walk: + - 1.3.6.1.2.1.25 + metrics: + - name: hrSystemUptime + oid: 1.3.6.1.2.1.25.1.1 + type: gauge + help: System uptime from HOST-RESOURCES-MIB. + - name: hrSystemNumUsers + oid: 1.3.6.1.2.1.25.1.5 + type: gauge + help: Number of users. + - name: hrSystemProcesses + oid: 1.3.6.1.2.1.25.1.6 + type: gauge + help: Number of running processes. + - name: hrSystemMaxProcesses + oid: 1.3.6.1.2.1.25.1.7 + type: gauge + help: Maximum number of processes. + - name: hrMemorySize + oid: 1.3.6.1.2.1.25.2.2 + type: gauge + help: Total memory size in kilobytes. + - name: hrStorageIndex + oid: 1.3.6.1.2.1.25.2.3.1.1 + type: gauge + help: Storage table index. + - name: hrStorageDescr + oid: 1.3.6.1.2.1.25.2.3.1.3 + type: DisplayString + help: Storage description. + indexes: + - labelname: hrStorageIndex + type: gauge + - name: hrStorageAllocationUnits + oid: 1.3.6.1.2.1.25.2.3.1.4 + type: gauge + help: Storage allocation unit size in bytes. + indexes: + - labelname: hrStorageIndex + type: gauge + lookups: + - labels: + - hrStorageIndex + labelname: hrStorageDescr + oid: 1.3.6.1.2.1.25.2.3.1.3 + type: DisplayString + - name: hrStorageSize + oid: 1.3.6.1.2.1.25.2.3.1.5 + type: gauge + help: Storage size in allocation units. + indexes: + - labelname: hrStorageIndex + type: gauge + lookups: + - labels: + - hrStorageIndex + labelname: hrStorageDescr + oid: 1.3.6.1.2.1.25.2.3.1.3 + type: DisplayString + - name: hrStorageUsed + oid: 1.3.6.1.2.1.25.2.3.1.6 + type: gauge + help: Used storage in allocation units. + indexes: + - labelname: hrStorageIndex + type: gauge + lookups: + - labels: + - hrStorageIndex + labelname: hrStorageDescr + oid: 1.3.6.1.2.1.25.2.3.1.3 + type: DisplayString + - name: hrStorageAllocationFailures + oid: 1.3.6.1.2.1.25.2.3.1.7 + type: counter + help: Storage allocation failures. + indexes: + - labelname: hrStorageIndex + type: gauge + lookups: + - labels: + - hrStorageIndex + labelname: hrStorageDescr + oid: 1.3.6.1.2.1.25.2.3.1.3 + type: DisplayString + - name: hrDeviceIndex + oid: 1.3.6.1.2.1.25.3.2.1.1 + type: gauge + help: Device table index. + - name: hrDeviceDescr + oid: 1.3.6.1.2.1.25.3.2.1.3 + type: DisplayString + help: Device description. + indexes: + - labelname: hrDeviceIndex + type: gauge + - name: hrDeviceStatus + oid: 1.3.6.1.2.1.25.3.2.1.5 + type: gauge + help: Device status. + indexes: + - labelname: hrDeviceIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + labelname: hrDeviceDescr + oid: 1.3.6.1.2.1.25.3.2.1.3 + type: DisplayString + - name: hrDeviceErrors + oid: 1.3.6.1.2.1.25.3.2.1.6 + type: counter + help: Device errors. + indexes: + - labelname: hrDeviceIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + labelname: hrDeviceDescr + oid: 1.3.6.1.2.1.25.3.2.1.3 + type: DisplayString + - name: hrProcessorLoad + oid: 1.3.6.1.2.1.25.3.3.1.2 + type: gauge + help: Average CPU load percentage. + indexes: + - labelname: hrDeviceIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + labelname: hrDeviceDescr + oid: 1.3.6.1.2.1.25.3.2.1.3 + type: DisplayString + if_mib: + walk: + - 1.3.6.1.2.1.2 + - 1.3.6.1.2.1.31.1.1 + metrics: + - name: ifNumber + oid: 1.3.6.1.2.1.2.1 + type: gauge + help: The number of network interfaces (regardless of their current state) present on this system. - 1.3.6.1.2.1.2.1 + - name: ifIndex + oid: 1.3.6.1.2.1.2.2.1.1 + type: gauge + help: A unique value, greater than zero, for each interface - 1.3.6.1.2.1.2.2.1.1 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifType + oid: 1.3.6.1.2.1.2.2.1.3 + type: EnumAsInfo + help: The type of interface - 1.3.6.1.2.1.2.2.1.3 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: other + 2: regular1822 + 3: hdh1822 + 4: ddnX25 + 5: rfc877x25 + 6: ethernetCsmacd + 7: iso88023Csmacd + 8: iso88024TokenBus + 9: iso88025TokenRing + 10: iso88026Man + 11: starLan + 12: proteon10Mbit + 13: proteon80Mbit + 14: hyperchannel + 15: fddi + 16: lapb + 17: sdlc + 18: ds1 + 19: e1 + 20: basicISDN + 21: primaryISDN + 22: propPointToPointSerial + 23: ppp + 24: softwareLoopback + 25: eon + 26: ethernet3Mbit + 27: nsip + 28: slip + 29: ultra + 30: ds3 + 31: sip + 32: frameRelay + 33: rs232 + 34: para + 35: arcnet + 36: arcnetPlus + 37: atm + 38: miox25 + 39: sonet + 40: x25ple + 41: iso88022llc + 42: localTalk + 43: smdsDxi + 44: frameRelayService + 45: v35 + 46: hssi + 47: hippi + 48: modem + 49: aal5 + 50: sonetPath + 51: sonetVT + 52: smdsIcip + 53: propVirtual + 54: propMultiplexor + 55: ieee80212 + 56: fibreChannel + 57: hippiInterface + 58: frameRelayInterconnect + 59: aflane8023 + 60: aflane8025 + 61: cctEmul + 62: fastEther + 63: isdn + 64: v11 + 65: v36 + 66: g703at64k + 67: g703at2mb + 68: qllc + 69: fastEtherFX + 70: channel + 71: ieee80211 + 72: ibm370parChan + 73: escon + 74: dlsw + 75: isdns + 76: isdnu + 77: lapd + 78: ipSwitch + 79: rsrb + 80: atmLogical + 81: ds0 + 82: ds0Bundle + 83: bsc + 84: async + 85: cnr + 86: iso88025Dtr + 87: eplrs + 88: arap + 89: propCnls + 90: hostPad + 91: termPad + 92: frameRelayMPI + 93: x213 + 94: adsl + 95: radsl + 96: sdsl + 97: vdsl + 98: iso88025CRFPInt + 99: myrinet + 100: voiceEM + 101: voiceFXO + 102: voiceFXS + 103: voiceEncap + 104: voiceOverIp + 105: atmDxi + 106: atmFuni + 107: atmIma + 108: pppMultilinkBundle + 109: ipOverCdlc + 110: ipOverClaw + 111: stackToStack + 112: virtualIpAddress + 113: mpc + 114: ipOverAtm + 115: iso88025Fiber + 116: tdlc + 117: gigabitEthernet + 118: hdlc + 119: lapf + 120: v37 + 121: x25mlp + 122: x25huntGroup + 123: transpHdlc + 124: interleave + 125: fast + 126: ip + 127: docsCableMaclayer + 128: docsCableDownstream + 129: docsCableUpstream + 130: a12MppSwitch + 131: tunnel + 132: coffee + 133: ces + 134: atmSubInterface + 135: l2vlan + 136: l3ipvlan + 137: l3ipxvlan + 138: digitalPowerline + 139: mediaMailOverIp + 140: dtm + 141: dcn + 142: ipForward + 143: msdsl + 144: ieee1394 + 145: if-gsn + 146: dvbRccMacLayer + 147: dvbRccDownstream + 148: dvbRccUpstream + 149: atmVirtual + 150: mplsTunnel + 151: srp + 152: voiceOverAtm + 153: voiceOverFrameRelay + 154: idsl + 155: compositeLink + 156: ss7SigLink + 157: propWirelessP2P + 158: frForward + 159: rfc1483 + 160: usb + 161: ieee8023adLag + 162: bgppolicyaccounting + 163: frf16MfrBundle + 164: h323Gatekeeper + 165: h323Proxy + 166: mpls + 167: mfSigLink + 168: hdsl2 + 169: shdsl + 170: ds1FDL + 171: pos + 172: dvbAsiIn + 173: dvbAsiOut + 174: plc + 175: nfas + 176: tr008 + 177: gr303RDT + 178: gr303IDT + 179: isup + 180: propDocsWirelessMaclayer + 181: propDocsWirelessDownstream + 182: propDocsWirelessUpstream + 183: hiperlan2 + 184: propBWAp2Mp + 185: sonetOverheadChannel + 186: digitalWrapperOverheadChannel + 187: aal2 + 188: radioMAC + 189: atmRadio + 190: imt + 191: mvl + 192: reachDSL + 193: frDlciEndPt + 194: atmVciEndPt + 195: opticalChannel + 196: opticalTransport + 197: propAtm + 198: voiceOverCable + 199: infiniband + 200: teLink + 201: q2931 + 202: virtualTg + 203: sipTg + 204: sipSig + 205: docsCableUpstreamChannel + 206: econet + 207: pon155 + 208: pon622 + 209: bridge + 210: linegroup + 211: voiceEMFGD + 212: voiceFGDEANA + 213: voiceDID + 214: mpegTransport + 215: sixToFour + 216: gtp + 217: pdnEtherLoop1 + 218: pdnEtherLoop2 + 219: opticalChannelGroup + 220: homepna + 221: gfp + 222: ciscoISLvlan + 223: actelisMetaLOOP + 224: fcipLink + 225: rpr + 226: qam + 227: lmp + 228: cblVectaStar + 229: docsCableMCmtsDownstream + 230: adsl2 + 231: macSecControlledIF + 232: macSecUncontrolledIF + 233: aviciOpticalEther + 234: atmbond + 235: voiceFGDOS + 236: mocaVersion1 + 237: ieee80216WMAN + 238: adsl2plus + 239: dvbRcsMacLayer + 240: dvbTdm + 241: dvbRcsTdma + 242: x86Laps + 243: wwanPP + 244: wwanPP2 + 245: voiceEBS + 246: ifPwType + 247: ilan + 248: pip + 249: aluELP + 250: gpon + 251: vdsl2 + 252: capwapDot11Profile + 253: capwapDot11Bss + 254: capwapWtpVirtualRadio + 255: bits + 256: docsCableUpstreamRfPort + 257: cableDownstreamRfPort + 258: vmwareVirtualNic + 259: ieee802154 + 260: otnOdu + 261: otnOtu + 262: ifVfiType + 263: g9981 + 264: g9982 + 265: g9983 + 266: aluEpon + 267: aluEponOnu + 268: aluEponPhysicalUni + 269: aluEponLogicalLink + 270: aluGponOnu + 271: aluGponPhysicalUni + 272: vmwareNicTeam + 277: docsOfdmDownstream + 278: docsOfdmaUpstream + 279: gfast + 280: sdci + 281: xboxWireless + 282: fastdsl + 283: docsCableScte55d1FwdOob + 284: docsCableScte55d1RetOob + 285: docsCableScte55d2DsOob + 286: docsCableScte55d2UsOob + 287: docsCableNdf + 288: docsCableNdr + 289: ptm + 290: ghn + 291: otnOtsi + 292: otnOtuc + 293: otnOduc + 294: otnOtsig + 295: microwaveCarrierTermination + 296: microwaveRadioLinkTerminal + 297: ieee8021axDrni + 298: ax25 + 299: ieee19061nanocom + 300: cpri + 301: omni + 302: roe + 303: p2pOverLan + 304: docsCableScte25d1FwdOob + 305: docsCableScte25d1RetOob + 306: docsCableScte25d2MacOob + 307: lora + 308: lorawan + - name: ifMtu + oid: 1.3.6.1.2.1.2.2.1.4 + type: gauge + help: The size of the largest packet which can be sent/received on the interface, specified in octets - 1.3.6.1.2.1.2.2.1.4 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifSpeed + oid: 1.3.6.1.2.1.2.2.1.5 + type: gauge + help: An estimate of the interface's current bandwidth in bits per second - 1.3.6.1.2.1.2.2.1.5 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifPhysAddress + oid: 1.3.6.1.2.1.2.2.1.6 + type: PhysAddress48 + help: The interface's address at its protocol sub-layer - 1.3.6.1.2.1.2.2.1.6 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifAdminStatus + oid: 1.3.6.1.2.1.2.2.1.7 + type: gauge + help: The desired state of the interface - 1.3.6.1.2.1.2.2.1.7 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: up + 2: down + 3: testing + - name: ifOperStatus + oid: 1.3.6.1.2.1.2.2.1.8 + type: gauge + help: The current operational state of the interface - 1.3.6.1.2.1.2.2.1.8 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: up + 2: down + 3: testing + 4: unknown + 5: dormant + 6: notPresent + 7: lowerLayerDown + - name: ifLastChange + oid: 1.3.6.1.2.1.2.2.1.9 + type: gauge + help: The value of sysUpTime at the time the interface entered its current operational state - 1.3.6.1.2.1.2.2.1.9 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInOctets + oid: 1.3.6.1.2.1.2.2.1.10 + type: counter + help: The total number of octets received on the interface, including framing characters - 1.3.6.1.2.1.2.2.1.10 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInUcastPkts + oid: 1.3.6.1.2.1.2.2.1.11 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer - 1.3.6.1.2.1.2.2.1.11 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInNUcastPkts + oid: 1.3.6.1.2.1.2.2.1.12 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast or broadcast address at this sub-layer - 1.3.6.1.2.1.2.2.1.12 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInDiscards + oid: 1.3.6.1.2.1.2.2.1.13 + type: counter + help: The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol - 1.3.6.1.2.1.2.2.1.13 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInErrors + oid: 1.3.6.1.2.1.2.2.1.14 + type: counter + help: For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol - 1.3.6.1.2.1.2.2.1.14 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInUnknownProtos + oid: 1.3.6.1.2.1.2.2.1.15 + type: counter + help: For packet-oriented interfaces, the number of packets received via the interface which were discarded because of an unknown or unsupported protocol - 1.3.6.1.2.1.2.2.1.15 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutOctets + oid: 1.3.6.1.2.1.2.2.1.16 + type: counter + help: The total number of octets transmitted out of the interface, including framing characters - 1.3.6.1.2.1.2.2.1.16 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutUcastPkts + oid: 1.3.6.1.2.1.2.2.1.17 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.2.2.1.17 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutNUcastPkts + oid: 1.3.6.1.2.1.2.2.1.18 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.2.2.1.18 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutDiscards + oid: 1.3.6.1.2.1.2.2.1.19 + type: counter + help: The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted - 1.3.6.1.2.1.2.2.1.19 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutErrors + oid: 1.3.6.1.2.1.2.2.1.20 + type: counter + help: For packet-oriented interfaces, the number of outbound packets that could not be transmitted because of errors - 1.3.6.1.2.1.2.2.1.20 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutQLen + oid: 1.3.6.1.2.1.2.2.1.21 + type: gauge + help: The length of the output packet queue (in packets). - 1.3.6.1.2.1.2.2.1.21 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifSpecific + oid: 1.3.6.1.2.1.2.2.1.22 + type: OctetString + help: A reference to MIB definitions specific to the particular media being used to realize the interface - 1.3.6.1.2.1.2.2.1.22 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInMulticastPkts + oid: 1.3.6.1.2.1.31.1.1.1.2 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast address at this sub-layer - 1.3.6.1.2.1.31.1.1.1.2 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifInBroadcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.3 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a broadcast address at this sub-layer - 1.3.6.1.2.1.31.1.1.1.3 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutMulticastPkts + oid: 1.3.6.1.2.1.31.1.1.1.4 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.31.1.1.1.4 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifOutBroadcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.5 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a broadcast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.31.1.1.1.5 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCInOctets + oid: 1.3.6.1.2.1.31.1.1.1.6 + type: counter + help: The total number of octets received on the interface, including framing characters - 1.3.6.1.2.1.31.1.1.1.6 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCInUcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.7 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer - 1.3.6.1.2.1.31.1.1.1.7 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCInMulticastPkts + oid: 1.3.6.1.2.1.31.1.1.1.8 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast address at this sub-layer - 1.3.6.1.2.1.31.1.1.1.8 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCInBroadcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.9 + type: counter + help: The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a broadcast address at this sub-layer - 1.3.6.1.2.1.31.1.1.1.9 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCOutOctets + oid: 1.3.6.1.2.1.31.1.1.1.10 + type: counter + help: The total number of octets transmitted out of the interface, including framing characters - 1.3.6.1.2.1.31.1.1.1.10 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCOutUcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.11 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.31.1.1.1.11 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCOutMulticastPkts + oid: 1.3.6.1.2.1.31.1.1.1.12 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.31.1.1.1.12 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifHCOutBroadcastPkts + oid: 1.3.6.1.2.1.31.1.1.1.13 + type: counter + help: The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a broadcast address at this sub-layer, including those that were discarded or not sent - 1.3.6.1.2.1.31.1.1.1.13 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifLinkUpDownTrapEnable + oid: 1.3.6.1.2.1.31.1.1.1.14 + type: gauge + help: Indicates whether linkUp/linkDown traps should be generated for this interface - 1.3.6.1.2.1.31.1.1.1.14 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: enabled + 2: disabled + - name: ifHighSpeed + oid: 1.3.6.1.2.1.31.1.1.1.15 + type: gauge + help: An estimate of the interface's current bandwidth in units of 1,000,000 bits per second - 1.3.6.1.2.1.31.1.1.1.15 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: ifPromiscuousMode + oid: 1.3.6.1.2.1.31.1.1.1.16 + type: gauge + help: This object has a value of false(2) if this interface only accepts packets/frames that are addressed to this station - 1.3.6.1.2.1.31.1.1.1.16 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: "true" + 2: "false" + - name: ifConnectorPresent + oid: 1.3.6.1.2.1.31.1.1.1.17 + type: gauge + help: This object has the value 'true(1)' if the interface sublayer has a physical connector and the value 'false(2)' otherwise. - 1.3.6.1.2.1.31.1.1.1.17 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + enum_values: + 1: "true" + 2: "false" + - name: ifCounterDiscontinuityTime + oid: 1.3.6.1.2.1.31.1.1.1.19 + type: gauge + help: The value of sysUpTime on the most recent occasion at which any one or more of this interface's counters suffered a discontinuity - 1.3.6.1.2.1.31.1.1.1.19 + indexes: + - labelname: ifIndex + type: gauge + lookups: + - labels: + - ifIndex + labelname: ifAlias + oid: 1.3.6.1.2.1.31.1.1.1.18 + type: DisplayString + - labels: + - ifIndex + labelname: ifDescr + oid: 1.3.6.1.2.1.2.2.1.2 + type: DisplayString + - labels: + - ifIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + mikrotik: + walk: + - 1.3.6.1.2.1.31.1.1.1.1 + - 1.3.6.1.4.1.14988 + metrics: + - name: mtxrWlStatIndex + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.1' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatTxRate + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.2 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.1.1.2 + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatRxRate + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.3 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.1.1.3 + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatStrength + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.4 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.1.1.1.4 + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatSsid + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.5 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.5' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatBssid + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.6 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.6' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatFreq + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.7 + type: gauge + help: megahertz - 1.3.6.1.4.1.14988.1.1.1.1.1.7 + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatBand + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.8 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.8' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatTxCCQ + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.9 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.9' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlStatRxCCQ + oid: 1.3.6.1.4.1.14988.1.1.1.1.1.10 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.1.1.10' + indexes: + - labelname: mtxrWlStatIndex + type: gauge + - name: mtxrWlRtabAddr + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.1 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.1' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabIface + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.2' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabStrength + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.3 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.1.2.1.3 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxBytes + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.4 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.4' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxBytes + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.5 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.5' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxPackets + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.6 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.6' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxPackets + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.7 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.7' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxRate + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.8 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.2.1.8 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxRate + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.9 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.2.1.9 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRouterOSVersion + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.10 + type: DisplayString + help: RouterOS version - 1.3.6.1.4.1.14988.1.1.1.2.1.10 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabUptime + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.11 + type: gauge + help: uptime - 1.3.6.1.4.1.14988.1.1.1.2.1.11 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabSignalToNoise + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.12 + type: gauge + help: Measured in dB, if value does not exist it is indicated with 0 - 1.3.6.1.4.1.14988.1.1.1.2.1.12 + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxStrengthCh0 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.13 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.13' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxStrengthCh0 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.14 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.14' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxStrengthCh1 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.15 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.15' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxStrengthCh1 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.16 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.16' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxStrengthCh2 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.17 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.17' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRxStrengthCh2 + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.18 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.18' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabTxStrength + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.19 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.19' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlRtabRadioName + oid: 1.3.6.1.4.1.14988.1.1.1.2.1.20 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.2.1.20' + indexes: + - labelname: mtxrWlRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlRtabIface + type: gauge + - name: mtxrWlApIndex + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.1' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApTxRate + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.2 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.3.1.2 + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApRxRate + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.3 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.3.1.3 + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApSsid + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.4' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApBssid + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.5 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.5' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApClientCount + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.6 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.6' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApFreq + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.7 + type: gauge + help: megahertz - 1.3.6.1.4.1.14988.1.1.1.3.1.7 + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApBand + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.8 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.8' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApNoiseFloor + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.9' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApOverallTxCCQ + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.10 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.10' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlApAuthClientCount + oid: 1.3.6.1.4.1.14988.1.1.1.3.1.11 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.3.1.11' + indexes: + - labelname: mtxrWlApIndex + type: gauge + - name: mtxrWlRtabEntryCount + oid: 1.3.6.1.4.1.14988.1.1.1.4 + type: gauge + help: Wireless registration table entry count - 1.3.6.1.4.1.14988.1.1.1.4 + - name: mtxrWlCMRtabAddr + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.1 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.1' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabIface + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.2' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabUptime + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.3 + type: gauge + help: uptime - 1.3.6.1.4.1.14988.1.1.1.5.1.3 + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabTxBytes + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.4 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.4' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabRxBytes + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.5 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.5' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabTxPackets + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.6 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.6' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabRxPackets + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.7 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.7' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabTxRate + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.8 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.5.1.8 + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabRxRate + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.9 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.1.5.1.9 + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabTxStrength + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.10 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.10' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabRxStrength + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.11 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.11' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabSsid + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.12 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.12' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabEapIdent + oid: 1.3.6.1.4.1.14988.1.1.1.5.1.13 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.5.1.13' + indexes: + - labelname: mtxrWlCMRtabAddr + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWlCMRtabIface + type: gauge + - name: mtxrWlCMRtabEntryCount + oid: 1.3.6.1.4.1.14988.1.1.1.6 + type: gauge + help: Wireless CAPSMAN registration table entry count - 1.3.6.1.4.1.14988.1.1.1.6 + - name: mtxrWlCMIndex + oid: 1.3.6.1.4.1.14988.1.1.1.7.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.7.1.1' + indexes: + - labelname: mtxrWlCMIndex + type: gauge + - name: mtxrWlCMRegClientCount + oid: 1.3.6.1.4.1.14988.1.1.1.7.1.2 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.7.1.2' + indexes: + - labelname: mtxrWlCMIndex + type: gauge + - name: mtxrWlCMAuthClientCount + oid: 1.3.6.1.4.1.14988.1.1.1.7.1.3 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.7.1.3' + indexes: + - labelname: mtxrWlCMIndex + type: gauge + - name: mtxrWlCMState + oid: 1.3.6.1.4.1.14988.1.1.1.7.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.7.1.4' + indexes: + - labelname: mtxrWlCMIndex + type: gauge + - name: mtxrWlCMChannel + oid: 1.3.6.1.4.1.14988.1.1.1.7.1.5 + type: DisplayString + help: for master only - 1.3.6.1.4.1.14988.1.1.1.7.1.5 + indexes: + - labelname: mtxrWlCMIndex + type: gauge + - name: mtxrWl60GIndex + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.1' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GMode + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.2' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + enum_values: + 0: apBridge + 1: stationBridge + 2: sniff + 3: bridge + - name: mtxrWl60GSsid + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.3 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.3' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GConnected + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.4 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.4' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + enum_values: + 0: "false" + 1: "true" + - name: mtxrWl60GRemote + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.5 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.5' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GFreq + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.6 + type: gauge + help: Mhz - 1.3.6.1.4.1.14988.1.1.1.8.1.6 + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GMcs + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.7 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.7' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GSignal + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.8' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GTxSector + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.9' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GTxSectorInfo + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.11 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.11' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GRssi + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.12 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.12' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GPhyRate + oid: 1.3.6.1.4.1.14988.1.1.1.8.1.13 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.8.1.13' + indexes: + - labelname: mtxrWl60GIndex + type: gauge + - name: mtxrWl60GStaIndex + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.1' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaConnected + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.2' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + enum_values: + 0: "false" + 1: "true" + - name: mtxrWl60GStaRemote + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.3 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.3' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaMcs + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.4 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.4' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaSignal + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.5 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.5' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaTxSector + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.6 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.6' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaPhyRate + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.8 + type: gauge + help: Mbits per second - 1.3.6.1.4.1.14988.1.1.1.9.1.8 + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaRssi + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.9.1.9' + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWl60GStaDistance + oid: 1.3.6.1.4.1.14988.1.1.1.9.1.10 + type: gauge + help: meters - 1.3.6.1.4.1.14988.1.1.1.9.1.10 + indexes: + - labelname: mtxrWl60GStaIndex + type: gauge + - name: mtxrWlCMREntryCount + oid: 1.3.6.1.4.1.14988.1.1.1.10 + type: gauge + help: Wireless CAPSMAN remote-cap entry count - 1.3.6.1.4.1.14988.1.1.1.10 + - name: mtxrWlCMRemoteIndex + oid: 1.3.6.1.4.1.14988.1.1.1.11.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.1.11.1.1' + indexes: + - labelname: mtxrWlCMRemoteIndex + type: gauge + - name: mtxrWlCMRemoteName + oid: 1.3.6.1.4.1.14988.1.1.1.11.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.11.1.2' + indexes: + - labelname: mtxrWlCMRemoteIndex + type: gauge + - name: mtxrWlCMRemoteState + oid: 1.3.6.1.4.1.14988.1.1.1.11.1.3 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.11.1.3' + indexes: + - labelname: mtxrWlCMRemoteIndex + type: gauge + - name: mtxrWlCMRemoteAddress + oid: 1.3.6.1.4.1.14988.1.1.1.11.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.1.11.1.4' + indexes: + - labelname: mtxrWlCMRemoteIndex + type: gauge + - name: mtxrWlCMRemoteRadios + oid: 1.3.6.1.4.1.14988.1.1.1.11.1.5 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.1.11.1.5' + indexes: + - labelname: mtxrWlCMRemoteIndex + type: gauge + - name: mtxrQueueSimpleIndex + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.1' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleName + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.2' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleSrcAddr + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.3 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.3' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleSrcMask + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.4 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.4' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleDstAddr + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.5 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.5' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleDstMask + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.6 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.6' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleIface + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.7 + type: gauge + help: interface index - 1.3.6.1.4.1.14988.1.1.2.1.1.7 + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleBytesIn + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.8 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.8' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleBytesOut + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.9 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.9' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimplePacketsIn + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.10 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.10' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimplePacketsOut + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.11 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.11' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimplePCQQueuesIn + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.12 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.12' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimplePCQQueuesOut + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.13 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.13' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleDroppedIn + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.14 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.14' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueSimpleDroppedOut + oid: 1.3.6.1.4.1.14988.1.1.2.1.1.15 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.1.1.15' + indexes: + - labelname: mtxrQueueSimpleIndex + type: gauge + - name: mtxrQueueTreeIndex + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.1' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeName + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.2' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeFlow + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.3 + type: DisplayString + help: flowmark - 1.3.6.1.4.1.14988.1.1.2.2.1.3 + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeParentIndex + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.4 + type: gauge + help: index of parent tree queue or parent interface - 1.3.6.1.4.1.14988.1.1.2.2.1.4 + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeBytes + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.5 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.5' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreePackets + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.6 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.6' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeHCBytes + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.7 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.7' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreePCQQueues + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.8 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.8' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrQueueTreeDropped + oid: 1.3.6.1.4.1.14988.1.1.2.2.1.9 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.2.2.1.9' + indexes: + - labelname: mtxrQueueTreeIndex + type: gauge + - name: mtxrHlCoreVoltage + oid: 1.3.6.1.4.1.14988.1.1.3.1 + type: gauge + help: core voltage - 1.3.6.1.4.1.14988.1.1.3.1 + - name: mtxrHlThreeDotThreeVoltage + oid: 1.3.6.1.4.1.14988.1.1.3.2 + type: gauge + help: 3.3V voltage - 1.3.6.1.4.1.14988.1.1.3.2 + - name: mtxrHlFiveVoltage + oid: 1.3.6.1.4.1.14988.1.1.3.3 + type: gauge + help: 5V voltage - 1.3.6.1.4.1.14988.1.1.3.3 + - name: mtxrHlTwelveVoltage + oid: 1.3.6.1.4.1.14988.1.1.3.4 + type: gauge + help: 12V voltage - 1.3.6.1.4.1.14988.1.1.3.4 + - name: mtxrHlSensorTemperature + oid: 1.3.6.1.4.1.14988.1.1.3.5 + type: gauge + help: temperature at sensor chip - 1.3.6.1.4.1.14988.1.1.3.5 + - name: mtxrHlCpuTemperature + oid: 1.3.6.1.4.1.14988.1.1.3.6 + type: gauge + help: temperature near cpu - 1.3.6.1.4.1.14988.1.1.3.6 + - name: mtxrHlBoardTemperature + oid: 1.3.6.1.4.1.14988.1.1.3.7 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.7' + - name: mtxrHlVoltage + oid: 1.3.6.1.4.1.14988.1.1.3.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.8' + - name: mtxrHlActiveFan + oid: 1.3.6.1.4.1.14988.1.1.3.9 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.3.9' + - name: mtxrHlTemperature + oid: 1.3.6.1.4.1.14988.1.1.3.10 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.10' + - name: mtxrHlProcessorTemperature + oid: 1.3.6.1.4.1.14988.1.1.3.11 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.11' + - name: mtxrHlPower + oid: 1.3.6.1.4.1.14988.1.1.3.12 + type: gauge + help: Watts - 1.3.6.1.4.1.14988.1.1.3.12 + - name: mtxrHlCurrent + oid: 1.3.6.1.4.1.14988.1.1.3.13 + type: gauge + help: mA - 1.3.6.1.4.1.14988.1.1.3.13 + - name: mtxrHlProcessorFrequency + oid: 1.3.6.1.4.1.14988.1.1.3.14 + type: gauge + help: Mhz - 1.3.6.1.4.1.14988.1.1.3.14 + - name: mtxrHlPowerSupplyState + oid: 1.3.6.1.4.1.14988.1.1.3.15 + type: gauge + help: PSU state ok - 1.3.6.1.4.1.14988.1.1.3.15 + enum_values: + 0: "false" + 1: "true" + - name: mtxrHlBackupPowerSupplyState + oid: 1.3.6.1.4.1.14988.1.1.3.16 + type: gauge + help: backup PSU state ok - 1.3.6.1.4.1.14988.1.1.3.16 + enum_values: + 0: "false" + 1: "true" + - name: mtxrHlFanSpeed1 + oid: 1.3.6.1.4.1.14988.1.1.3.17 + type: gauge + help: rpm - 1.3.6.1.4.1.14988.1.1.3.17 + - name: mtxrHlFanSpeed2 + oid: 1.3.6.1.4.1.14988.1.1.3.18 + type: gauge + help: rpm - 1.3.6.1.4.1.14988.1.1.3.18 + - name: mtxrAlarmSocketStatus + oid: 1.3.6.1.4.1.14988.1.1.3.19 + type: gauge + help: Alarm socket status - 1.3.6.1.4.1.14988.1.1.3.19 + enum_values: + 0: inactive + 1: active + - name: mtxrGaugeIndex + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.100.1.1' + indexes: + - labelname: mtxrGaugeIndex + type: gauge + lookups: + - labels: + - mtxrGaugeIndex + labelname: mtxrGaugeName + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.2 + type: DisplayString + - labels: [] + labelname: mtxrGaugeIndex + - name: mtxrGaugeName + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.3.100.1.2' + indexes: + - labelname: mtxrGaugeIndex + type: gauge + lookups: + - labels: + - mtxrGaugeIndex + labelname: mtxrGaugeName + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.2 + type: DisplayString + - labels: [] + labelname: mtxrGaugeIndex + - name: mtxrGaugeValue + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.3 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.3.100.1.3' + indexes: + - labelname: mtxrGaugeIndex + type: gauge + lookups: + - labels: + - mtxrGaugeIndex + labelname: mtxrGaugeName + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.2 + type: DisplayString + - labels: [] + labelname: mtxrGaugeIndex + - name: mtxrGaugeUnit + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.4 + type: gauge + help: units - 1.3.6.1.4.1.14988.1.1.3.100.1.4 + indexes: + - labelname: mtxrGaugeIndex + type: gauge + lookups: + - labels: + - mtxrGaugeIndex + labelname: mtxrGaugeName + oid: 1.3.6.1.4.1.14988.1.1.3.100.1.2 + type: DisplayString + - labels: [] + labelname: mtxrGaugeIndex + enum_values: + 1: celsius + 2: rpm + 3: dV + 4: dA + 5: dW + 6: status + - name: mtxrLicSoftwareId + oid: 1.3.6.1.4.1.14988.1.1.4.1 + type: DisplayString + help: software id - 1.3.6.1.4.1.14988.1.1.4.1 + - name: mtxrLicUpgrUntil + oid: 1.3.6.1.4.1.14988.1.1.4.2 + type: DateAndTime + help: current key allows upgrading until this date - 1.3.6.1.4.1.14988.1.1.4.2 + - name: mtxrLicLevel + oid: 1.3.6.1.4.1.14988.1.1.4.3 + type: gauge + help: current key level - 1.3.6.1.4.1.14988.1.1.4.3 + - name: mtxrLicVersion + oid: 1.3.6.1.4.1.14988.1.1.4.4 + type: DisplayString + help: software version - 1.3.6.1.4.1.14988.1.1.4.4 + - name: mtxrLicUpgradableTo + oid: 1.3.6.1.4.1.14988.1.1.4.5 + type: gauge + help: upgradable to - 1.3.6.1.4.1.14988.1.1.4.5 + - name: mtxrHotspotActiveUserIndex + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.1' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserServerID + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.2' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserName + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.3 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.3' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserDomain + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.4' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserIP + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.5 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.5' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserMAC + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.6 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.6' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserConnectTime + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.7 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.7' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserValidTillTime + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.8' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserIdleStartTime + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.9' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserIdleTimeout + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.10 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.10' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserPingTimeout + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.11 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.11' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserBytesIn + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.12 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.12' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserBytesOut + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.13 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.13' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserPacketsIn + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.14 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.14' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserPacketsOut + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.15 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.15' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserLimitBytesIn + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.16 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.16' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserLimitBytesOut + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.17 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.17' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserAdvertStatus + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.18 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.18' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserRadius + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.19 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.19' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrHotspotActiveUserBlockedByAdvert + oid: 1.3.6.1.4.1.14988.1.1.5.1.1.20 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.5.1.1.20' + indexes: + - labelname: mtxrHotspotActiveUserIndex + type: gauge + - name: mtxrDHCPLeaseCount + oid: 1.3.6.1.4.1.14988.1.1.6.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.6.1' + - name: mtxrSystemReboot + oid: 1.3.6.1.4.1.14988.1.1.7.1 + type: gauge + help: set non zero to reboot - 1.3.6.1.4.1.14988.1.1.7.1 + - name: mtxrUSBPowerReset + oid: 1.3.6.1.4.1.14988.1.1.7.2 + type: gauge + help: switches off usb power for specified amout of seconds - 1.3.6.1.4.1.14988.1.1.7.2 + - name: mtxrSerialNumber + oid: 1.3.6.1.4.1.14988.1.1.7.3 + type: DisplayString + help: RouterBOARD serial number - 1.3.6.1.4.1.14988.1.1.7.3 + - name: mtxrFirmwareVersion + oid: 1.3.6.1.4.1.14988.1.1.7.4 + type: DisplayString + help: Current firmware version - 1.3.6.1.4.1.14988.1.1.7.4 + - name: mtxrNote + oid: 1.3.6.1.4.1.14988.1.1.7.5 + type: DisplayString + help: note - 1.3.6.1.4.1.14988.1.1.7.5 + - name: mtxrBuildTime + oid: 1.3.6.1.4.1.14988.1.1.7.6 + type: DisplayString + help: build time - 1.3.6.1.4.1.14988.1.1.7.6 + - name: mtxrFirmwareUpgradeVersion + oid: 1.3.6.1.4.1.14988.1.1.7.7 + type: DisplayString + help: Upgrade firmware version - 1.3.6.1.4.1.14988.1.1.7.7 + - name: mtxrDisplayName + oid: 1.3.6.1.4.1.14988.1.1.7.8 + type: DisplayString + help: display name - 1.3.6.1.4.1.14988.1.1.7.8 + - name: mtxrBoardName + oid: 1.3.6.1.4.1.14988.1.1.7.9 + type: DisplayString + help: board name - 1.3.6.1.4.1.14988.1.1.7.9 + - name: mtxrScriptIndex + oid: 1.3.6.1.4.1.14988.1.1.8.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.8.1.1.1' + indexes: + - labelname: mtxrScriptIndex + type: gauge + - name: mtxrScriptName + oid: 1.3.6.1.4.1.14988.1.1.8.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.8.1.1.2' + indexes: + - labelname: mtxrScriptIndex + type: gauge + - name: mtxrScriptRunCmd + oid: 1.3.6.1.4.1.14988.1.1.8.1.1.3 + type: gauge + help: set non zero to run - 1.3.6.1.4.1.14988.1.1.8.1.1.3 + indexes: + - labelname: mtxrScriptIndex + type: gauge + - name: mtxrDnStatIndex + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.10.1.1.1' + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrDnStatTxRate + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.2 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.10.1.1.2 + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrDnStatRxRate + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.3 + type: gauge + help: bits per second - 1.3.6.1.4.1.14988.1.1.10.1.1.3 + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrDnStatTxStrength + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.4 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.10.1.1.4 + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrDnStatRxStrength + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.5 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.10.1.1.5 + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrDnConnected + oid: 1.3.6.1.4.1.14988.1.1.10.1.1.6 + type: gauge + help: 0 - not connected, connected otherwise - 1.3.6.1.4.1.14988.1.1.10.1.1.6 + indexes: + - labelname: mtxrDnStatIndex + type: gauge + - name: mtxrNeighborIndex + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.1' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborIpAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.2 + type: InetAddressIPv4 + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.2' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.3' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborVersion + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.4' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborPlatform + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.5 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.5' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborIdentity + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.6 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.6' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborSoftwareID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.7 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.7' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.11.1.1.8' + indexes: + - labelname: mtxrNeighborIndex + type: gauge + - labelname: mtxrNeighborInterfaceID + type: gauge + lookups: + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborMacAddress + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.3 + type: PhysAddress48 + - labels: + - mtxrNeighborIndex + labelname: mtxrNeighborInterfaceID + oid: 1.3.6.1.4.1.14988.1.1.11.1.1.8 + type: gauge + - labels: + - mtxrNeighborInterfaceID + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrNeighborIndex + - labels: [] + labelname: mtxrNeighborInterfaceID + - name: mtxrDate + oid: 1.3.6.1.4.1.14988.1.1.12.1 + type: gauge + help: UNIX time - 1.3.6.1.4.1.14988.1.1.12.1 + - name: mtxrLongtitude + oid: 1.3.6.1.4.1.14988.1.1.12.2 + type: DisplayString + help: longtitude - 1.3.6.1.4.1.14988.1.1.12.2 + - name: mtxrLatitude + oid: 1.3.6.1.4.1.14988.1.1.12.3 + type: DisplayString + help: latitude - 1.3.6.1.4.1.14988.1.1.12.3 + - name: mtxrAltitude + oid: 1.3.6.1.4.1.14988.1.1.12.4 + type: DisplayString + help: altitude - 1.3.6.1.4.1.14988.1.1.12.4 + - name: mtxrSpeed + oid: 1.3.6.1.4.1.14988.1.1.12.5 + type: DisplayString + help: speed - 1.3.6.1.4.1.14988.1.1.12.5 + - name: mtxrSattelites + oid: 1.3.6.1.4.1.14988.1.1.12.6 + type: gauge + help: visible sattelite count - 1.3.6.1.4.1.14988.1.1.12.6 + - name: mtxrValid + oid: 1.3.6.1.4.1.14988.1.1.12.7 + type: gauge + help: is the data valid - 1.3.6.1.4.1.14988.1.1.12.7 + - name: mtxrWirelessModemSignalStrength + oid: 1.3.6.1.4.1.14988.1.1.13.1 + type: gauge + help: signal strength in dBm (if first ppp-client modem supports) - 1.3.6.1.4.1.14988.1.1.13.1 + - name: mtxrWirelessModemSignalECIO + oid: 1.3.6.1.4.1.14988.1.1.13.2 + type: gauge + help: signal EC/IO in dB (if first ppp-client modem supports) - 1.3.6.1.4.1.14988.1.1.13.2 + - name: mtxrWirelessModemManufacturer + oid: 1.3.6.1.4.1.14988.1.1.13.3 + type: DisplayString + help: Modem manufacturer name - 1.3.6.1.4.1.14988.1.1.13.3 + - name: mtxrWirelessModemModel + oid: 1.3.6.1.4.1.14988.1.1.13.4 + type: DisplayString + help: Modem model name - 1.3.6.1.4.1.14988.1.1.13.4 + - name: mtxrWirelessModemRevision + oid: 1.3.6.1.4.1.14988.1.1.13.5 + type: DisplayString + help: Modem firmware revision - 1.3.6.1.4.1.14988.1.1.13.5 + - name: mtxrWirelessModemIMEI + oid: 1.3.6.1.4.1.14988.1.1.13.6 + type: DisplayString + help: Modem serial number - 1.3.6.1.4.1.14988.1.1.13.6 + - name: mtxrWirelessModemIMSI + oid: 1.3.6.1.4.1.14988.1.1.13.7 + type: DisplayString + help: International mobile subscriber identity - 1.3.6.1.4.1.14988.1.1.13.7 + - name: mtxrWirelessModemAccessTechnology + oid: 1.3.6.1.4.1.14988.1.1.13.8 + type: DisplayString + help: Access technology - 1.3.6.1.4.1.14988.1.1.13.8 + - name: mtxrWirelessModemFrameErrorRate + oid: 1.3.6.1.4.1.14988.1.1.13.9 + type: DisplayString + help: Signal frame error rate - 1.3.6.1.4.1.14988.1.1.13.9 + - name: mtxrWirelessModemRSRP + oid: 1.3.6.1.4.1.14988.1.1.13.10 + type: gauge + help: Reference Signal Receive Power - 1.3.6.1.4.1.14988.1.1.13.10 + - name: mtxrWirelessModemRSRQ + oid: 1.3.6.1.4.1.14988.1.1.13.11 + type: gauge + help: Reference Signal Received Quality - 1.3.6.1.4.1.14988.1.1.13.11 + - name: mtxrWirelessModemSINR + oid: 1.3.6.1.4.1.14988.1.1.13.12 + type: gauge + help: Signal-to-Interference-plus-Noise Ratio - 1.3.6.1.4.1.14988.1.1.13.12 + - name: mtxrWirelessModemPinStatus + oid: 1.3.6.1.4.1.14988.1.1.13.13 + type: DisplayString + help: Pin status of the modem - 1.3.6.1.4.1.14988.1.1.13.13 + - name: mtxrInterfaceStatsIndex + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.1' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsName + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.2' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsDriverRxBytes + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.11 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.11' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsDriverRxPackets + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.12 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.12' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsDriverTxBytes + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.13 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.13' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsDriverTxPackets + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.14 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.14' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx64 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.15 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.15' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx65To127 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.16 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.16' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx128To255 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.17 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.17' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx256To511 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.18 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.18' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx512To1023 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.19 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.19' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx1024To1518 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.20 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.20' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx1519ToMax + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.21 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.21' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxBytes + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.31 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.31' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxPackets + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.32 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.32' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxTooShort + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.33 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.33' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx64 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.34 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.34' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx65To127 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.35 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.35' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx128To255 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.36 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.36' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx256To511 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.37 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.37' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx512To1023 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.38 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.38' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx1024To1518 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.39 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.39' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRx1519ToMax + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.40 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.40' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxTooLong + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.41 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.41' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxBroadcast + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.42 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.42' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxPause + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.43 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.43' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxMulticast + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.44 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.44' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxFCSError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.45 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.45' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxAlignError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.46 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.46' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxFragment + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.47 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.47' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxOverflow + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.48 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.48' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxControl + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.49 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.49' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxUnknownOp + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.50 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.50' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxLengthError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.51 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.51' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxCodeError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.52 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.52' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxCarrierError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.53 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.53' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxJabber + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.54 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.54' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsRxDrop + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.55 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.55' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxBytes + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.61 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.61' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxPackets + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.62 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.62' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxTooShort + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.63 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.63' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx64 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.64 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.64' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx65To127 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.65 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.65' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx128To255 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.66 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.66' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx256To511 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.67 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.67' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx512To1023 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.68 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.68' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx1024To1518 + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.69 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.69' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTx1519ToMax + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.70 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.70' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxTooLong + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.71 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.71' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxBroadcast + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.72 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.72' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxPause + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.73 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.73' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxMulticast + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.74 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.74' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxUnderrun + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.75 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.75' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.76 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.76' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxExcessiveCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.77 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.77' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxMultipleCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.78 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.78' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxSingleCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.79 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.79' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxExcessiveDeferred + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.80 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.80' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxDeferred + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.81 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.81' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxLateCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.82 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.82' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxTotalCollision + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.83 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.83' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxPauseHonored + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.84 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.84' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxDrop + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.85 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.85' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxJabber + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.86 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.86' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxFCSError + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.87 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.87' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxControl + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.88 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.88' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxFragment + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.89 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.89' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsLinkDowns + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.90 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.90' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrInterfaceStatsTxRx1024ToMax + oid: 1.3.6.1.4.1.14988.1.1.14.1.1.91 + type: counter + help: ' - 1.3.6.1.4.1.14988.1.1.14.1.1.91' + indexes: + - labelname: mtxrInterfaceStatsIndex + type: gauge + lookups: + - labels: + - mtxrInterfaceStatsIndex + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - name: mtxrPOEInterfaceIndex + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.15.1.1.1' + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + - name: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.15.1.1.2' + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + - name: mtxrPOEStatus + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.3 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.15.1.1.3' + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + enum_values: + 1: disabled + 2: waitingForLoad + 3: poweredOn + 4: overload + 5: shortCircuit + 6: voltageTooLow + 7: currentTooLow + 8: powerReset + 9: voltageTooHigh + 10: controllerError + 11: controllerUpgrade + 12: poeInDetected + 13: noValidPsu + 14: controllerInit + 15: lowVoltageTooLow + - name: mtxrPOEVoltage + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.4 + type: gauge + help: V - 1.3.6.1.4.1.14988.1.1.15.1.1.4 + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + - name: mtxrPOECurrent + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.5 + type: gauge + help: mA - 1.3.6.1.4.1.14988.1.1.15.1.1.5 + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + - name: mtxrPOEPower + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.6 + type: gauge + help: W - 1.3.6.1.4.1.14988.1.1.15.1.1.6 + indexes: + - labelname: mtxrPOEInterfaceIndex + type: gauge + lookups: + - labels: + - mtxrPOEInterfaceIndex + labelname: mtxrPOEName + oid: 1.3.6.1.4.1.14988.1.1.15.1.1.2 + type: DisplayString + - name: mtxrLTEModemInterfaceIndex + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.1' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSignalRSSI + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.2 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.16.1.1.2 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSignalRSRQ + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.3 + type: gauge + help: dB - 1.3.6.1.4.1.14988.1.1.16.1.1.3 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSignalRSRP + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.4 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.16.1.1.4 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemCellId + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.5 + type: gauge + help: current cell ID - 1.3.6.1.4.1.14988.1.1.16.1.1.5 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemAccessTechnology + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.6 + type: gauge + help: as reported by +CREG - 1.3.6.1.4.1.14988.1.1.16.1.1.6 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + enum_values: + -1: unknown + 0: gsmcompact + 1: gsm + 2: utran + 3: egprs + 4: hsdpa + 5: hsupa + 6: hsdpahsupa + 7: eutran + 11: nr-sa + 13: nr-nsa + - name: mtxrLTEModemSignalSINR + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.7 + type: gauge + help: dB - 1.3.6.1.4.1.14988.1.1.16.1.1.7 + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemEnbId + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.8' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSectorId + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.9' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemLac + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.10 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.10' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemIMEI + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.11 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.11' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemIMSI + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.12 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.12' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemUICC + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.13 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.13' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemRAT + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.14 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.14' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemPrimaryBand + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.15 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.15' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSessionUptime + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.16 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.16' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemRegStatus + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.17 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.17' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemPinStatus + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.18 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.18' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemModel + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.19 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.19' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemFirmware + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.20 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.20' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemCQI + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.21 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.21' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemNrRSRP + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.22 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.22' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemNrRSRQ + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.23 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.23' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemNrSINR + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.24 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.24' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTEModemSignalRSRQD10 + oid: 1.3.6.1.4.1.14988.1.1.16.1.1.25 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.1.1.25' + indexes: + - labelname: mtxrLTEModemInterfaceIndex + type: gauge + - name: mtxrLTECarrierAggInterfaceIndex + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.1' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggIndex + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.2 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.2' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggBand + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.3 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.3' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggEARFCN + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.4 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.4' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggBandwidth + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.5 + type: gauge + help: MHz - 1.3.6.1.4.1.14988.1.1.16.2.1.1.5 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggPhyCellId + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.6 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.6' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggRSSI + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.7 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.16.2.1.1.7 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggRSRP + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.8 + type: gauge + help: dBm - 1.3.6.1.4.1.14988.1.1.16.2.1.1.8 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggRSRQ + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.9 + type: gauge + help: dB - 1.3.6.1.4.1.14988.1.1.16.2.1.1.9 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggSINR + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.10 + type: gauge + help: dB - 1.3.6.1.4.1.14988.1.1.16.2.1.1.10 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggSNR + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.11 + type: gauge + help: dB - 1.3.6.1.4.1.14988.1.1.16.2.1.1.11 + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + - name: mtxrLTECarrierAggNR + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.12 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.12' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + enum_values: + 1: "true" + 2: "false" + - name: mtxrLTECarrierAggUplink + oid: 1.3.6.1.4.1.14988.1.1.16.2.1.1.13 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.16.2.1.1.13' + indexes: + - labelname: mtxrLTECarrierAggInterfaceIndex + type: gauge + - labelname: mtxrLTECarrierAggIndex + type: gauge + enum_values: + 1: "true" + 2: "false" + - name: mtxrPartitionIndex + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.17.1.1.1' + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + - name: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.17.1.1.2' + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + - name: mtxrPartitionSize + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.3 + type: gauge + help: MB - 1.3.6.1.4.1.14988.1.1.17.1.1.3 + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + - name: mtxrPartitionVersion + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.4 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.17.1.1.4' + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + - name: mtxrPartitionActive + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.5 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.17.1.1.5' + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + enum_values: + 0: "false" + 1: "true" + - name: mtxrPartitionRunning + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.6 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.17.1.1.6' + indexes: + - labelname: mtxrPartitionIndex + type: gauge + lookups: + - labels: + - mtxrPartitionIndex + labelname: mtxrPartitionName + oid: 1.3.6.1.4.1.14988.1.1.17.1.1.2 + type: DisplayString + enum_values: + 0: "false" + 1: "true" + - name: mtxrScriptRunIndex + oid: 1.3.6.1.4.1.14988.1.1.18.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.18.1.1.1' + indexes: + - labelname: mtxrScriptRunIndex + type: gauge + - name: mtxrScriptRunOutput + oid: 1.3.6.1.4.1.14988.1.1.18.1.1.2 + type: DisplayString + help: this oid on get request will run script and return it's output - 1.3.6.1.4.1.14988.1.1.18.1.1.2 + indexes: + - labelname: mtxrScriptRunIndex + type: gauge + - name: mtxrOpticalIndex + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.1' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.2' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalRxLoss + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.3 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.3' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + enum_values: + 0: "false" + 1: "true" + - name: mtxrOpticalTxFault + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.4 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.4' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + enum_values: + 0: "false" + 1: "true" + - name: mtxrOpticalWavelength + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.5 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.5' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalTemperature + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.6 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.6' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalSupplyVoltage + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.7 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.7' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalTxBiasCurrent + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.8' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalTxPower + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.9 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.9' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalRxPower + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.10 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.10' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalVendorName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.11 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.11' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrOpticalVendorSerial + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.12 + type: DisplayString + help: ' - 1.3.6.1.4.1.14988.1.1.19.1.1.12' + indexes: + - labelname: mtxrOpticalIndex + type: gauge + lookups: + - labels: + - mtxrOpticalIndex + labelname: mtxrOpticalName + oid: 1.3.6.1.4.1.14988.1.1.19.1.1.2 + type: DisplayString + - name: mtxrIkeSACount + oid: 1.3.6.1.4.1.14988.1.1.20.1 + type: gauge + help: IKE SA count - 1.3.6.1.4.1.14988.1.1.20.1 + - name: mtxrIkeSAIndex + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.1 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.1' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAInitiatorCookie + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.2 + type: DisplayString + help: initiator SPI - 1.3.6.1.4.1.14988.1.1.20.2.1.2 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAResponderCookie + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.3 + type: DisplayString + help: responder SPI - 1.3.6.1.4.1.14988.1.1.20.2.1.3 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAResponder + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.4 + type: gauge + help: IKE side - 1.3.6.1.4.1.14988.1.1.20.2.1.4 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 0: "false" + 1: "true" + - name: mtxrIkeSANatt + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.5 + type: gauge + help: NAT is detected - 1.3.6.1.4.1.14988.1.1.20.2.1.5 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 0: "false" + 1: "true" + - name: mtxrIkeSAVersion + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.6 + type: gauge + help: protocol version - 1.3.6.1.4.1.14988.1.1.20.2.1.6 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAState + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.7 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.7' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 1: exchange + 2: established + 3: expired + 4: eap + - name: mtxrIkeSAUptime + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.8 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.8' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSASeen + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.9 + type: gauge + help: time elapsed since last valid IKE packet - 1.3.6.1.4.1.14988.1.1.20.2.1.9 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAIdentity + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.10 + type: DisplayString + help: peer identity - 1.3.6.1.4.1.14988.1.1.20.2.1.10 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAPh2Count + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.11 + type: gauge + help: total ph2 SA pairs - 1.3.6.1.4.1.14988.1.1.20.2.1.11 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSALocalAddressType + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.12 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.12' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 0: unknown + 1: ipv4 + 2: ipv6 + 3: ipv4z + 4: ipv6z + 16: dns + - name: mtxrIkeSALocalAddress + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.13 + type: InetAddress + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.13' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSALocalPort + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.14 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.14' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAPeerAddressType + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.15 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.15' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 0: unknown + 1: ipv4 + 2: ipv6 + 3: ipv4z + 4: ipv6z + 16: dns + - name: mtxrIkeSAPeerAddress + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.16 + type: InetAddress + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.16' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSAPeerPort + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.17 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.17' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSADynamicAddressType + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.18 + type: gauge + help: ' - 1.3.6.1.4.1.14988.1.1.20.2.1.18' + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + enum_values: + 0: unknown + 1: ipv4 + 2: ipv6 + 3: ipv4z + 4: ipv6z + 16: dns + - name: mtxrIkeSADynamicAddress + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.19 + type: InetAddress + help: dynamic address allocated by mode config - 1.3.6.1.4.1.14988.1.1.20.2.1.19 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSATxBytes + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.20 + type: counter + help: ph2 SA tx bytes - 1.3.6.1.4.1.14988.1.1.20.2.1.20 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSARxBytes + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.21 + type: counter + help: ph2 SA rx bytes - 1.3.6.1.4.1.14988.1.1.20.2.1.21 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSATxPackets + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.22 + type: counter + help: ph2 SA tx packets - 1.3.6.1.4.1.14988.1.1.20.2.1.22 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrIkeSARxPackets + oid: 1.3.6.1.4.1.14988.1.1.20.2.1.23 + type: counter + help: ph2 SA rx packets - 1.3.6.1.4.1.14988.1.1.20.2.1.23 + indexes: + - labelname: mtxrIkeSAIndex + type: gauge + - name: mtxrWifiCapsmanEnabled + oid: 1.3.6.1.4.1.14988.1.1.21.1.1 + type: gauge + help: Indicates whether the Capsman is enabled. - 1.3.6.1.4.1.14988.1.1.21.1.1 + enum_values: + 1: "true" + 2: "false" + - name: mtxrWifiCapsmanInterfaces + oid: 1.3.6.1.4.1.14988.1.1.21.1.2 + type: DisplayString + help: List of interfaces associated with Capsman. - 1.3.6.1.4.1.14988.1.1.21.1.2 + - name: mtxrWifiCapsmanCACertificate + oid: 1.3.6.1.4.1.14988.1.1.21.1.3 + type: DisplayString + help: The CA certificate used by Capsman. - 1.3.6.1.4.1.14988.1.1.21.1.3 + - name: mtxrWifiCapsmanCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.1.4 + type: DisplayString + help: The local certificate used by Capsman. - 1.3.6.1.4.1.14988.1.1.21.1.4 + - name: mtxrWifiCapsmanRequirePeerCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.1.5 + type: gauge + help: Whether a peer certificate is required. - 1.3.6.1.4.1.14988.1.1.21.1.5 + enum_values: + 1: "true" + 2: "false" + - name: mtxrWifiCapsmanPackagePath + oid: 1.3.6.1.4.1.14988.1.1.21.1.6 + type: DisplayString + help: Path to the Capsman package directory. - 1.3.6.1.4.1.14988.1.1.21.1.6 + - name: mtxrWifiCapsmanUpgradePolicy + oid: 1.3.6.1.4.1.14988.1.1.21.1.7 + type: gauge + help: Capsman upgrade policy. - 1.3.6.1.4.1.14988.1.1.21.1.7 + - name: mtxrWifiCapsmanGeneratedCaCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.1.8 + type: DisplayString + help: Automatically generated CA certificate. - 1.3.6.1.4.1.14988.1.1.21.1.8 + - name: mtxrWifiCapsmanGeneratedCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.1.9 + type: DisplayString + help: Automatically generated local certificate. - 1.3.6.1.4.1.14988.1.1.21.1.9 + - name: mtxrCapEnabled + oid: 1.3.6.1.4.1.14988.1.1.21.2.1 + type: gauge + help: Indicates whether the CAP is enabled. - 1.3.6.1.4.1.14988.1.1.21.2.1 + enum_values: + 1: "true" + 2: "false" + - name: mtxrCapInterfaces + oid: 1.3.6.1.4.1.14988.1.1.21.2.2 + type: DisplayString + help: List of interfaces used by the CAP. - 1.3.6.1.4.1.14988.1.1.21.2.2 + - name: mtxrCapCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.2.3 + type: DisplayString + help: The local certificate used by the CAP. - 1.3.6.1.4.1.14988.1.1.21.2.3 + - name: mtxrCapCapsManAddresses + oid: 1.3.6.1.4.1.14988.1.1.21.2.4 + type: DisplayString + help: Addresses of associated CapsMan controllers. - 1.3.6.1.4.1.14988.1.1.21.2.4 + - name: mtxrCapCapsManNames + oid: 1.3.6.1.4.1.14988.1.1.21.2.5 + type: DisplayString + help: Names of associated CapsMan controllers. - 1.3.6.1.4.1.14988.1.1.21.2.5 + - name: mtxrCapCapsManCertificateCommonNames + oid: 1.3.6.1.4.1.14988.1.1.21.2.6 + type: DisplayString + help: Common names of CapsMan certificates. - 1.3.6.1.4.1.14988.1.1.21.2.6 + - name: mtxrCapLockToCapsMan + oid: 1.3.6.1.4.1.14988.1.1.21.2.7 + type: gauge + help: Indicates if the CAP is locked to a specific CapsMan. - 1.3.6.1.4.1.14988.1.1.21.2.7 + enum_values: + 1: "true" + 2: "false" + - name: mtxrCapSlavesStatic + oid: 1.3.6.1.4.1.14988.1.1.21.2.8 + type: gauge + help: Indicates if CAP slaves are set to static mode. - 1.3.6.1.4.1.14988.1.1.21.2.8 + enum_values: + 1: "true" + 2: "false" + - name: mtxrCapSlavesDatapath + oid: 1.3.6.1.4.1.14988.1.1.21.2.9 + type: DisplayString + help: Datapath configuration of CAP slaves. - 1.3.6.1.4.1.14988.1.1.21.2.9 + - name: mtxrCapRequestedCertificate + oid: 1.3.6.1.4.1.14988.1.1.21.2.10 + type: DisplayString + help: Requested certificate for the CAP. - 1.3.6.1.4.1.14988.1.1.21.2.10 + - name: mtxrCapLockedCapsManCommonName + oid: 1.3.6.1.4.1.14988.1.1.21.2.11 + type: DisplayString + help: Locked CapsMan common name. - 1.3.6.1.4.1.14988.1.1.21.2.11 + - name: mtxrCapCurrentCapsManAddress + oid: 1.3.6.1.4.1.14988.1.1.21.2.12 + type: DisplayString + help: Current CapsMan address being used. - 1.3.6.1.4.1.14988.1.1.21.2.12 + - name: mtxrCapCurrentCapsManIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.2.13 + type: DisplayString + help: Current identity of the connected CapsMan. - 1.3.6.1.4.1.14988.1.1.21.2.13 + - name: mtxrRemoteCapId + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.1 + type: gauge + help: ID of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.1 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapAddress + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.2 + type: DisplayString + help: IP address of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.2 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapBoardName + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.4 + type: DisplayString + help: Board name of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.4 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapSerial + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.5 + type: DisplayString + help: Serial number of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.5 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapVersion + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.6 + type: DisplayString + help: RouterOS version of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.6 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapBaseMac + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.7 + type: PhysAddress48 + help: Base MAC address of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.7 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapCommonName + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.8 + type: DisplayString + help: Certificate common name of the remote CAP. - 1.3.6.1.4.1.14988.1.1.21.3.1.8 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrRemoteCapState + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.9 + type: DisplayString + help: State of the remote CAP (e.g., connected, disconnected). - 1.3.6.1.4.1.14988.1.1.21.3.1.9 + indexes: + - labelname: mtxrRemoteCapId + type: gauge + lookups: + - labels: + - mtxrRemoteCapId + labelname: mtxrRemoteCapIdentity + oid: 1.3.6.1.4.1.14988.1.1.21.3.1.3 + type: DisplayString + - labels: [] + labelname: mtxrRemoteCapId + - name: mtxrWifiRegistrationInterface + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.2 + type: gauge + help: Interface id of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.2 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationSsid + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.3 + type: DisplayString + help: SSID of the connected access point. - 1.3.6.1.4.1.14988.1.1.21.4.1.3 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationUptime + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.4 + type: gauge + help: Uptime of the registered connection. - 1.3.6.1.4.1.14988.1.1.21.4.1.4 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationLastActivity + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.5 + type: gauge + help: Time since the last activity of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.5 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationSignal + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.6 + type: gauge + help: Signal strength of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.6 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationAuthType + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.7 + type: DisplayString + help: Authentication type used by the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.7 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationBand + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.8 + type: DisplayString + help: Wireless band used by the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.8 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationTxRate + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.9 + type: gauge + help: Transmission rate of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.9 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationRxRate + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.10 + type: gauge + help: Reception rate of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.10 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationTxPackets + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.11 + type: counter + help: Number of transmitted packets. - 1.3.6.1.4.1.14988.1.1.21.4.1.11 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationRxPackets + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.12 + type: counter + help: Number of received packets. - 1.3.6.1.4.1.14988.1.1.21.4.1.12 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationTxBytes + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.13 + type: counter + help: Number of transmitted bytes. - 1.3.6.1.4.1.14988.1.1.21.4.1.13 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationRxBytes + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.14 + type: counter + help: Number of received bytes. - 1.3.6.1.4.1.14988.1.1.21.4.1.14 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationTxBitsPerSecond + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.15 + type: gauge + help: Transmission rate in bits per second. - 1.3.6.1.4.1.14988.1.1.21.4.1.15 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationRxBitsPerSecond + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.16 + type: gauge + help: Reception rate in bits per second. - 1.3.6.1.4.1.14988.1.1.21.4.1.16 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationVlanId + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.17 + type: gauge + help: VLAN ID of the registered device. - 1.3.6.1.4.1.14988.1.1.21.4.1.17 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + - name: mtxrWifiRegistrationAuthorized + oid: 1.3.6.1.4.1.14988.1.1.21.4.1.18 + type: gauge + help: Indicates whether the device is authorized. - 1.3.6.1.4.1.14988.1.1.21.4.1.18 + indexes: + - labelname: mtxrWifiRegistrationMacAddress + type: PhysAddress48 + fixed_size: 6 + - labelname: mtxrWifiRegistrationInterface + type: gauge + lookups: + - labels: + - mtxrWifiRegistrationInterface + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiRegistrationInterface + enum_values: + 1: "true" + 2: "false" + - name: mtxrWifiInterfacesId + oid: 1.3.6.1.4.1.14988.1.1.21.5.1.1 + type: gauge + help: Unique identifier for each WiFi interface - 1.3.6.1.4.1.14988.1.1.21.5.1.1 + indexes: + - labelname: mtxrWifiInterfacesId + type: gauge + lookups: + - labels: + - mtxrWifiInterfacesId + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiInterfacesId + - name: mtxrWifiInterfacesSsid + oid: 1.3.6.1.4.1.14988.1.1.21.5.1.3 + type: DisplayString + help: SSID associated with the WiFi interface - 1.3.6.1.4.1.14988.1.1.21.5.1.3 + indexes: + - labelname: mtxrWifiInterfacesId + type: gauge + lookups: + - labels: + - mtxrWifiInterfacesId + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiInterfacesId + - name: mtxrWifiInterfacesFreq + oid: 1.3.6.1.4.1.14988.1.1.21.5.1.4 + type: DisplayString + help: Frequency used by the WiFi interface - 1.3.6.1.4.1.14988.1.1.21.5.1.4 + indexes: + - labelname: mtxrWifiInterfacesId + type: gauge + lookups: + - labels: + - mtxrWifiInterfacesId + labelname: ifName + oid: 1.3.6.1.2.1.31.1.1.1.1 + type: DisplayString + - labels: [] + labelname: mtxrWifiInterfacesId + - name: mtxrCtTotalEntries + oid: 1.3.6.1.4.1.14988.1.1.22.1 + type: counter + help: Total number of connections - 1.3.6.1.4.1.14988.1.1.22.1 + - name: mtxrCtIP4Entries + oid: 1.3.6.1.4.1.14988.1.1.22.2 + type: counter + help: Total number of ipv4 connections - 1.3.6.1.4.1.14988.1.1.22.2 + - name: mtxrCtIP6Entries + oid: 1.3.6.1.4.1.14988.1.1.22.3 + type: counter + help: Total number of ipv6 connections - 1.3.6.1.4.1.14988.1.1.22.3 + synology: + walk: + - 1.3.6.1.4.1.6574.1 + - 1.3.6.1.4.1.6574.101 + - 1.3.6.1.4.1.6574.102 + - 1.3.6.1.4.1.6574.104 + - 1.3.6.1.4.1.6574.2 + - 1.3.6.1.4.1.6574.3 + - 1.3.6.1.4.1.6574.4 + - 1.3.6.1.4.1.6574.5 + - 1.3.6.1.4.1.6574.6 + metrics: + - name: systemStatus + oid: 1.3.6.1.4.1.6574.1.1 + type: gauge + help: Synology system status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.1 + - name: temperature + oid: 1.3.6.1.4.1.6574.1.2 + type: gauge + help: Synology system temperature The temperature of Disk Station uses Celsius degree. - 1.3.6.1.4.1.6574.1.2 + - name: powerStatus + oid: 1.3.6.1.4.1.6574.1.3 + type: gauge + help: Synology power status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.3 + - name: systemFanStatus + oid: 1.3.6.1.4.1.6574.1.4.1 + type: gauge + help: Synology system fan status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.4.1 + - name: cpuFanStatus + oid: 1.3.6.1.4.1.6574.1.4.2 + type: gauge + help: Synology cpu fan status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.1.4.2 + - name: modelName + oid: 1.3.6.1.4.1.6574.1.5.1 + type: DisplayString + help: The Model name of this NAS - 1.3.6.1.4.1.6574.1.5.1 + - name: serialNumber + oid: 1.3.6.1.4.1.6574.1.5.2 + type: DisplayString + help: The serial number of this NAS - 1.3.6.1.4.1.6574.1.5.2 + - name: version + oid: 1.3.6.1.4.1.6574.1.5.3 + type: DisplayString + help: The version of this DSM - 1.3.6.1.4.1.6574.1.5.3 + - name: upgradeAvailable + oid: 1.3.6.1.4.1.6574.1.5.4 + type: gauge + help: This oid is for checking whether there is a latest DSM can be upgraded - 1.3.6.1.4.1.6574.1.5.4 + - name: controllerNumber + oid: 1.3.6.1.4.1.6574.1.6 + type: gauge + help: Synology system controller number Controller A(0) Controller B(1) - 1.3.6.1.4.1.6574.1.6 + - name: storageIOIndex + oid: 1.3.6.1.4.1.6574.101.1.1.1 + type: gauge + help: Reference index for each observed device. - 1.3.6.1.4.1.6574.101.1.1.1 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.2 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIONRead + oid: 1.3.6.1.4.1.6574.101.1.1.3 + type: counter + help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.3 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIONWritten + oid: 1.3.6.1.4.1.6574.101.1.1.4 + type: counter + help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.4 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOReads + oid: 1.3.6.1.4.1.6574.101.1.1.5 + type: counter + help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.5 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOWrites + oid: 1.3.6.1.4.1.6574.101.1.1.6 + type: counter + help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.6 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOLA + oid: 1.3.6.1.4.1.6574.101.1.1.8 + type: gauge + help: The load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.8 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOLA1 + oid: 1.3.6.1.4.1.6574.101.1.1.9 + type: gauge + help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.9 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOLA5 + oid: 1.3.6.1.4.1.6574.101.1.1.10 + type: gauge + help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.10 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIOLA15 + oid: 1.3.6.1.4.1.6574.101.1.1.11 + type: gauge + help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.101.1.1.11 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIONReadX + oid: 1.3.6.1.4.1.6574.101.1.1.12 + type: counter + help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.101.1.1.12 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIONWrittenX + oid: 1.3.6.1.4.1.6574.101.1.1.13 + type: counter + help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.101.1.1.13 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: storageIODeviceSerial + oid: 1.3.6.1.4.1.6574.101.1.1.14 + type: DisplayString + help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.101.1.1.14 + indexes: + - labelname: storageIOIndex + type: gauge + lookups: + - labels: + - storageIOIndex + labelname: storageIODevice + oid: 1.3.6.1.4.1.6574.101.1.1.2 + type: DisplayString + - labels: [] + labelname: storageIOIndex + - name: spaceIOIndex + oid: 1.3.6.1.4.1.6574.102.1.1.1 + type: gauge + help: Reference index for each observed device. - 1.3.6.1.4.1.6574.102.1.1.1 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + help: The name of the device we are counting/checking. - 1.3.6.1.4.1.6574.102.1.1.2 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIONRead + oid: 1.3.6.1.4.1.6574.102.1.1.3 + type: counter + help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.3 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIONWritten + oid: 1.3.6.1.4.1.6574.102.1.1.4 + type: counter + help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.4 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOReads + oid: 1.3.6.1.4.1.6574.102.1.1.5 + type: counter + help: The number of read accesses from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.5 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOWrites + oid: 1.3.6.1.4.1.6574.102.1.1.6 + type: counter + help: The number of write accesses to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.6 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOLA + oid: 1.3.6.1.4.1.6574.102.1.1.8 + type: gauge + help: The load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.8 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOLA1 + oid: 1.3.6.1.4.1.6574.102.1.1.9 + type: gauge + help: The 1 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.9 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOLA5 + oid: 1.3.6.1.4.1.6574.102.1.1.10 + type: gauge + help: The 5 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.10 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIOLA15 + oid: 1.3.6.1.4.1.6574.102.1.1.11 + type: gauge + help: The 15 minute average load of disk (%) - 1.3.6.1.4.1.6574.102.1.1.11 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIONReadX + oid: 1.3.6.1.4.1.6574.102.1.1.12 + type: counter + help: The number of bytes read from this device since boot. - 1.3.6.1.4.1.6574.102.1.1.12 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceIONWrittenX + oid: 1.3.6.1.4.1.6574.102.1.1.13 + type: counter + help: The number of bytes written to this device since boot. - 1.3.6.1.4.1.6574.102.1.1.13 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: spaceUUID + oid: 1.3.6.1.4.1.6574.102.1.1.14 + type: DisplayString + help: The uuid of space. - 1.3.6.1.4.1.6574.102.1.1.14 + indexes: + - labelname: spaceIOIndex + type: gauge + lookups: + - labels: + - spaceIOIndex + labelname: spaceIODevice + oid: 1.3.6.1.4.1.6574.102.1.1.2 + type: DisplayString + - labels: [] + labelname: spaceIOIndex + - name: iSCSILUNInfoIndex + oid: 1.3.6.1.4.1.6574.104.1.1.1 + type: gauge + help: LUN info index - 1.3.6.1.4.1.6574.104.1.1.1 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNUUID + oid: 1.3.6.1.4.1.6574.104.1.1.2 + type: OctetString + help: LUN uuid - 1.3.6.1.4.1.6574.104.1.1.2 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNName + oid: 1.3.6.1.4.1.6574.104.1.1.3 + type: OctetString + help: LUN name - 1.3.6.1.4.1.6574.104.1.1.3 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNThroughputReadHigh + oid: 1.3.6.1.4.1.6574.104.1.1.4 + type: gauge + help: LUN read throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.4 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNThroughputReadLow + oid: 1.3.6.1.4.1.6574.104.1.1.5 + type: gauge + help: LUN read throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.5 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNThroughputWriteHigh + oid: 1.3.6.1.4.1.6574.104.1.1.6 + type: gauge + help: LUN write throughput over 32 bits part - 1.3.6.1.4.1.6574.104.1.1.6 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNThroughputWriteLow + oid: 1.3.6.1.4.1.6574.104.1.1.7 + type: gauge + help: LUN write throughput in unsigned 32 bit - 1.3.6.1.4.1.6574.104.1.1.7 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNIopsRead + oid: 1.3.6.1.4.1.6574.104.1.1.8 + type: gauge + help: LUN read iops - 1.3.6.1.4.1.6574.104.1.1.8 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNIopsWrite + oid: 1.3.6.1.4.1.6574.104.1.1.9 + type: gauge + help: LUN write iops - 1.3.6.1.4.1.6574.104.1.1.9 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNDiskLatencyRead + oid: 1.3.6.1.4.1.6574.104.1.1.10 + type: gauge + help: LUN disk latency when reading - 1.3.6.1.4.1.6574.104.1.1.10 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNDiskLatencyWrite + oid: 1.3.6.1.4.1.6574.104.1.1.11 + type: gauge + help: LUN disk latency when writing - 1.3.6.1.4.1.6574.104.1.1.11 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNNetworkLatencyTx + oid: 1.3.6.1.4.1.6574.104.1.1.12 + type: gauge + help: LUN transfer data network latency - 1.3.6.1.4.1.6574.104.1.1.12 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNNetworkLatencyRx + oid: 1.3.6.1.4.1.6574.104.1.1.13 + type: gauge + help: LUN receive data network latency - 1.3.6.1.4.1.6574.104.1.1.13 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNIoSizeRead + oid: 1.3.6.1.4.1.6574.104.1.1.14 + type: gauge + help: LUN average io size when reading - 1.3.6.1.4.1.6574.104.1.1.14 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNIoSizeWrite + oid: 1.3.6.1.4.1.6574.104.1.1.15 + type: gauge + help: LUN average io size when writing - 1.3.6.1.4.1.6574.104.1.1.15 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNQueueDepth + oid: 1.3.6.1.4.1.6574.104.1.1.16 + type: gauge + help: Num of iSCSI commands in LUN queue - 1.3.6.1.4.1.6574.104.1.1.16 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNType + oid: 1.3.6.1.4.1.6574.104.1.1.17 + type: OctetString + help: LUN type - 1.3.6.1.4.1.6574.104.1.1.17 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNDiskLatencyAvg + oid: 1.3.6.1.4.1.6574.104.1.1.18 + type: gauge + help: Average latency of LUN disk - 1.3.6.1.4.1.6574.104.1.1.18 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: iSCSILUNThinProvisionVolFreeMBs + oid: 1.3.6.1.4.1.6574.104.1.1.19 + type: gauge + help: Free space(MB) of thin provisioning lun's volume - 1.3.6.1.4.1.6574.104.1.1.19 + indexes: + - labelname: iSCSILUNInfoIndex + type: gauge + - name: diskIndex + oid: 1.3.6.1.4.1.6574.2.1.1.1 + type: gauge + help: The index of disk table - 1.3.6.1.4.1.6574.2.1.1.1 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + help: Synology disk ID The ID of disk is assigned by disk Station. - 1.3.6.1.4.1.6574.2.1.1.2 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskModel + oid: 1.3.6.1.4.1.6574.2.1.1.3 + type: DisplayString + help: Synology disk model name The disk model name will be showed here. - 1.3.6.1.4.1.6574.2.1.1.3 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskType + oid: 1.3.6.1.4.1.6574.2.1.1.4 + type: DisplayString + help: Synology disk type The type of disk will be showed here, including SATA, SSD and so on. - 1.3.6.1.4.1.6574.2.1.1.4 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskStatus + oid: 1.3.6.1.4.1.6574.2.1.1.5 + type: gauge + help: Synology disk status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.2.1.1.5 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskTemperature + oid: 1.3.6.1.4.1.6574.2.1.1.6 + type: gauge + help: Synology disk temperature The temperature of each disk uses Celsius degree. - 1.3.6.1.4.1.6574.2.1.1.6 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskRole + oid: 1.3.6.1.4.1.6574.2.1.1.7 + type: DisplayString + help: Synology disk role The role of the disk in system - 1.3.6.1.4.1.6574.2.1.1.7 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskRetry + oid: 1.3.6.1.4.1.6574.2.1.1.8 + type: gauge + help: Synology disk retry count The count of each disk connection retries. - 1.3.6.1.4.1.6574.2.1.1.8 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskBadSector + oid: 1.3.6.1.4.1.6574.2.1.1.9 + type: gauge + help: Synology disk bad sector count The count of each disk I/O bad sector. - 1.3.6.1.4.1.6574.2.1.1.9 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskIdentifyFail + oid: 1.3.6.1.4.1.6574.2.1.1.10 + type: gauge + help: Synology disk identify fail count The count of each disk identify fails. - 1.3.6.1.4.1.6574.2.1.1.10 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskRemainLife + oid: 1.3.6.1.4.1.6574.2.1.1.11 + type: gauge + help: Synology disk remainLife The estimate remain life of each disk. - 1.3.6.1.4.1.6574.2.1.1.11 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskName + oid: 1.3.6.1.4.1.6574.2.1.1.12 + type: DisplayString + help: Synology disk name The name of disk which align to storage manager. - 1.3.6.1.4.1.6574.2.1.1.12 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: diskHealthStatus + oid: 1.3.6.1.4.1.6574.2.1.1.13 + type: gauge + help: Synology disk health status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.2.1.1.13 + indexes: + - labelname: diskIndex + type: gauge + lookups: + - labels: + - diskIndex + labelname: diskID + oid: 1.3.6.1.4.1.6574.2.1.1.2 + type: DisplayString + - labels: [] + labelname: diskIndex + - name: raidIndex + oid: 1.3.6.1.4.1.6574.3.1.1.1 + type: gauge + help: The index of raid table - 1.3.6.1.4.1.6574.3.1.1.1 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + help: Synology raid name The name of each raid will be showed here. - 1.3.6.1.4.1.6574.3.1.1.2 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: raidStatus + oid: 1.3.6.1.4.1.6574.3.1.1.3 + type: gauge + help: Synology Raid status Each meanings of status represented describe below - 1.3.6.1.4.1.6574.3.1.1.3 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: raidFreeSize + oid: 1.3.6.1.4.1.6574.3.1.1.4 + type: gauge + help: Synology raid freesize Free space in bytes. - 1.3.6.1.4.1.6574.3.1.1.4 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: raidTotalSize + oid: 1.3.6.1.4.1.6574.3.1.1.5 + type: gauge + help: Synology raid totalsize Total space in bytes. - 1.3.6.1.4.1.6574.3.1.1.5 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: raidHotspareCnt + oid: 1.3.6.1.4.1.6574.3.1.1.6 + type: gauge + help: Synology raid hotspare Total hotspare disks count - 1.3.6.1.4.1.6574.3.1.1.6 + indexes: + - labelname: raidIndex + type: gauge + lookups: + - labels: + - raidIndex + labelname: raidName + oid: 1.3.6.1.4.1.6574.3.1.1.2 + type: DisplayString + - labels: [] + labelname: raidIndex + - name: upsDeviceModel + oid: 1.3.6.1.4.1.6574.4.1.1 + type: DisplayString + help: Device model - 1.3.6.1.4.1.6574.4.1.1 + - name: upsDeviceManufacturer + oid: 1.3.6.1.4.1.6574.4.1.2 + type: DisplayString + help: Device manufacturer - 1.3.6.1.4.1.6574.4.1.2 + - name: upsDeviceSerial + oid: 1.3.6.1.4.1.6574.4.1.3 + type: DisplayString + help: Device serial number. - 1.3.6.1.4.1.6574.4.1.3 + - name: upsDeviceType + oid: 1.3.6.1.4.1.6574.4.1.4 + type: DisplayString + help: Device type (ups, pdu, scd, psu) - 1.3.6.1.4.1.6574.4.1.4 + - name: upsDeviceDescription + oid: 1.3.6.1.4.1.6574.4.1.5 + type: DisplayString + help: Device description. - 1.3.6.1.4.1.6574.4.1.5 + - name: upsDeviceContact + oid: 1.3.6.1.4.1.6574.4.1.6 + type: DisplayString + help: Device administrator name. - 1.3.6.1.4.1.6574.4.1.6 + - name: upsDeviceLocation + oid: 1.3.6.1.4.1.6574.4.1.7 + type: DisplayString + help: Device physical location. - 1.3.6.1.4.1.6574.4.1.7 + - name: upsDevicePart + oid: 1.3.6.1.4.1.6574.4.1.8 + type: DisplayString + help: Device part number. - 1.3.6.1.4.1.6574.4.1.8 + - name: upsDeviceMACAddr + oid: 1.3.6.1.4.1.6574.4.1.9 + type: DisplayString + help: Physical network address of the device. - 1.3.6.1.4.1.6574.4.1.9 + - name: upsInfoStatus + oid: 1.3.6.1.4.1.6574.4.2.1 + type: DisplayString + help: UPS status. - 1.3.6.1.4.1.6574.4.2.1 + - name: upsInfoAlarm + oid: 1.3.6.1.4.1.6574.4.2.2 + type: DisplayString + help: UPS alarms - 1.3.6.1.4.1.6574.4.2.2 + - name: upsInfoTime + oid: 1.3.6.1.4.1.6574.4.2.3 + type: DisplayString + help: Internal UPS clock time - 1.3.6.1.4.1.6574.4.2.3 + - name: upsInfoDate + oid: 1.3.6.1.4.1.6574.4.2.4 + type: DisplayString + help: Internal UPS clock date - 1.3.6.1.4.1.6574.4.2.4 + - name: upsInfoModel + oid: 1.3.6.1.4.1.6574.4.2.5 + type: DisplayString + help: UPS model - 1.3.6.1.4.1.6574.4.2.5 + - name: upsInfoMfrName + oid: 1.3.6.1.4.1.6574.4.2.6.1 + type: DisplayString + help: UPS manufacturer - 1.3.6.1.4.1.6574.4.2.6.1 + - name: upsInfoMfrDate + oid: 1.3.6.1.4.1.6574.4.2.6.2 + type: DisplayString + help: UPS manufacturing date - 1.3.6.1.4.1.6574.4.2.6.2 + - name: upsInfoSerial + oid: 1.3.6.1.4.1.6574.4.2.7 + type: DisplayString + help: UPS serial number - 1.3.6.1.4.1.6574.4.2.7 + - name: upsInfoVendorID + oid: 1.3.6.1.4.1.6574.4.2.8 + type: DisplayString + help: Vendor ID for USB devices - 1.3.6.1.4.1.6574.4.2.8 + - name: upsInfoProductID + oid: 1.3.6.1.4.1.6574.4.2.9 + type: DisplayString + help: Product ID for USB devices - 1.3.6.1.4.1.6574.4.2.9 + - name: upsInfoFirmwareName + oid: 1.3.6.1.4.1.6574.4.2.10.1 + type: DisplayString + help: UPS firmware - 1.3.6.1.4.1.6574.4.2.10.1 + - name: upsInfoFirmwareAux + oid: 1.3.6.1.4.1.6574.4.2.10.2 + type: DisplayString + help: Auxiliary device firmware - 1.3.6.1.4.1.6574.4.2.10.2 + - name: upsInfoTemperature + oid: 1.3.6.1.4.1.6574.4.2.11 + type: Float + help: UPS temperature (degrees C) - 1.3.6.1.4.1.6574.4.2.11 + - name: upsInfoLoadValue + oid: 1.3.6.1.4.1.6574.4.2.12.1 + type: Float + help: Load on UPS (percent) - 1.3.6.1.4.1.6574.4.2.12.1 + - name: upsInfoLoadHigh + oid: 1.3.6.1.4.1.6574.4.2.12.2 + type: Float + help: Load when UPS switches to overload condition (OVER) (percent) - 1.3.6.1.4.1.6574.4.2.12.2 + - name: upsInfoID + oid: 1.3.6.1.4.1.6574.4.2.13 + type: DisplayString + help: UPS system identifier - 1.3.6.1.4.1.6574.4.2.13 + - name: upsInfoDelayStart + oid: 1.3.6.1.4.1.6574.4.2.14.1 + type: gauge + help: Interval to wait before restarting the load (seconds) - 1.3.6.1.4.1.6574.4.2.14.1 + - name: upsInfoDelayReboot + oid: 1.3.6.1.4.1.6574.4.2.14.2 + type: gauge + help: Interval to wait before rebooting the UPS (seconds) - 1.3.6.1.4.1.6574.4.2.14.2 + - name: upsInfoDelayShutdown + oid: 1.3.6.1.4.1.6574.4.2.14.3 + type: gauge + help: Interval to wait after shutdown with delay command (seconds) - 1.3.6.1.4.1.6574.4.2.14.3 + - name: upsInfoTimerStart + oid: 1.3.6.1.4.1.6574.4.2.15.1 + type: gauge + help: Time before the load will be started (seconds) - 1.3.6.1.4.1.6574.4.2.15.1 + - name: upsInfoTimerReboot + oid: 1.3.6.1.4.1.6574.4.2.15.2 + type: gauge + help: Time before the load will be rebooted (seconds) - 1.3.6.1.4.1.6574.4.2.15.2 + - name: upsInfoTimerShutdown + oid: 1.3.6.1.4.1.6574.4.2.15.3 + type: gauge + help: Time before the load will be shutdown (seconds) - 1.3.6.1.4.1.6574.4.2.15.3 + - name: upsInfoTestInterval + oid: 1.3.6.1.4.1.6574.4.2.16.1 + type: gauge + help: Interval between self tests - 1.3.6.1.4.1.6574.4.2.16.1 + - name: upsInfoTestResult + oid: 1.3.6.1.4.1.6574.4.2.16.2 + type: DisplayString + help: Results of last self test - 1.3.6.1.4.1.6574.4.2.16.2 + - name: upsInfoDisplayLanguage + oid: 1.3.6.1.4.1.6574.4.2.17 + type: DisplayString + help: Language to use on front panel - 1.3.6.1.4.1.6574.4.2.17 + - name: upsInfoContacts + oid: 1.3.6.1.4.1.6574.4.2.18 + type: DisplayString + help: UPS external contact sensors - 1.3.6.1.4.1.6574.4.2.18 + - name: upsInfoEffciency + oid: 1.3.6.1.4.1.6574.4.2.19 + type: gauge + help: Efficiency of the UPS (ratio of the output current on the input current) (percent) - 1.3.6.1.4.1.6574.4.2.19 + - name: upsInfoPowerValue + oid: 1.3.6.1.4.1.6574.4.2.20.1 + type: Float + help: Current value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.1 + - name: upsInfoPowerNominal + oid: 1.3.6.1.4.1.6574.4.2.20.2 + type: Float + help: Nominal value of apparent power (Volt-Amps) - 1.3.6.1.4.1.6574.4.2.20.2 + - name: upsInfoRealPowerValue + oid: 1.3.6.1.4.1.6574.4.2.21.1 + type: Float + help: Current value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.1 + - name: upsInfoRealPowerNominal + oid: 1.3.6.1.4.1.6574.4.2.21.2 + type: Float + help: Nominal value of real power (Watts) - 1.3.6.1.4.1.6574.4.2.21.2 + - name: upsInfoBeeperStatus + oid: 1.3.6.1.4.1.6574.4.2.22 + type: DisplayString + help: UPS beeper status (enabled, disabled or muted) - 1.3.6.1.4.1.6574.4.2.22 + - name: upsInfoType + oid: 1.3.6.1.4.1.6574.4.2.23 + type: DisplayString + help: UPS type - 1.3.6.1.4.1.6574.4.2.23 + - name: upsInfoWatchdogStatus + oid: 1.3.6.1.4.1.6574.4.2.24 + type: DisplayString + help: UPS watchdog status (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.24 + - name: upsInfoStartAuto + oid: 1.3.6.1.4.1.6574.4.2.25.1 + type: DisplayString + help: UPS starts when mains is (re)applied - 1.3.6.1.4.1.6574.4.2.25.1 + - name: upsInfoStartBattery + oid: 1.3.6.1.4.1.6574.4.2.25.2 + type: DisplayString + help: Allow to start UPS from battery - 1.3.6.1.4.1.6574.4.2.25.2 + - name: upsInfoStartReboot + oid: 1.3.6.1.4.1.6574.4.2.25.3 + type: DisplayString + help: UPS coldstarts from battery (enabled or disabled) - 1.3.6.1.4.1.6574.4.2.25.3 + - name: upsBatteryChargeValue + oid: 1.3.6.1.4.1.6574.4.3.1.1 + type: Float + help: Battery charge - 1.3.6.1.4.1.6574.4.3.1.1 + - name: upsBatteryChargeLow + oid: 1.3.6.1.4.1.6574.4.3.1.2 + type: Float + help: Remaining battery level when UPS switches to LB (percent) - 1.3.6.1.4.1.6574.4.3.1.2 + - name: upsBatteryChargeRestart + oid: 1.3.6.1.4.1.6574.4.3.1.3 + type: Float + help: Minimum battery level for UPS restart after power-off - 1.3.6.1.4.1.6574.4.3.1.3 + - name: upsBatteryChargeWarning + oid: 1.3.6.1.4.1.6574.4.3.1.4 + type: Float + help: Battery level when UPS switches to Warning state (percent) - 1.3.6.1.4.1.6574.4.3.1.4 + - name: upsBatteryVoltageValue + oid: 1.3.6.1.4.1.6574.4.3.2.1 + type: Float + help: The magnitude of the present battery voltage. - 1.3.6.1.4.1.6574.4.3.2.1 + - name: upsBatteryVoltageNominal + oid: 1.3.6.1.4.1.6574.4.3.2.2 + type: Float + help: Nominal battery voltage. - 1.3.6.1.4.1.6574.4.3.2.2 + - name: upsBatteryVoltageLow + oid: 1.3.6.1.4.1.6574.4.3.2.3 + type: Float + help: Minimum battery voltage, that triggers FSD status . - 1.3.6.1.4.1.6574.4.3.2.3 + - name: upsBatteryVoltageHigh + oid: 1.3.6.1.4.1.6574.4.3.2.4 + type: Float + help: Maximum battery voltage (Ie battery.charge = 100). - 1.3.6.1.4.1.6574.4.3.2.4 + - name: upsBatteryCapacity + oid: 1.3.6.1.4.1.6574.4.3.3 + type: Float + help: Battery capacity (Ah) - 1.3.6.1.4.1.6574.4.3.3 + - name: upsBatteryCurrent + oid: 1.3.6.1.4.1.6574.4.3.4 + type: Float + help: The present battery current. - 1.3.6.1.4.1.6574.4.3.4 + - name: upsBatteryTemperature + oid: 1.3.6.1.4.1.6574.4.3.5 + type: Float + help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.4.1.6574.4.3.5 + - name: upsBatteryRuntimeValue + oid: 1.3.6.1.4.1.6574.4.3.6.1 + type: gauge + help: Battery runtime (seconds) - 1.3.6.1.4.1.6574.4.3.6.1 + - name: upsBatteryRuntimeLow + oid: 1.3.6.1.4.1.6574.4.3.6.2 + type: gauge + help: Remaining battery runtime when UPS switches to LB (seconds) - 1.3.6.1.4.1.6574.4.3.6.2 + - name: upsBatteryRuntimeRestart + oid: 1.3.6.1.4.1.6574.4.3.6.3 + type: gauge + help: Minimum battery runtime for UPS restart after power-off (seconds) - 1.3.6.1.4.1.6574.4.3.6.3 + - name: upsBatteryAlarmThreshold + oid: 1.3.6.1.4.1.6574.4.3.7 + type: DisplayString + help: Battery alarm threshold - 1.3.6.1.4.1.6574.4.3.7 + - name: upsBatteryDate + oid: 1.3.6.1.4.1.6574.4.3.8 + type: DisplayString + help: Battery change date - 1.3.6.1.4.1.6574.4.3.8 + - name: upsBatteryMfrDate + oid: 1.3.6.1.4.1.6574.4.3.9 + type: DisplayString + help: Battery manufacturing date - 1.3.6.1.4.1.6574.4.3.9 + - name: upsBatteryPacks + oid: 1.3.6.1.4.1.6574.4.3.10 + type: gauge + help: Number of battery packs - 1.3.6.1.4.1.6574.4.3.10 + - name: upsBatteryPacksBad + oid: 1.3.6.1.4.1.6574.4.3.11 + type: gauge + help: Number of bad battery packs - 1.3.6.1.4.1.6574.4.3.11 + - name: upsBatteryType + oid: 1.3.6.1.4.1.6574.4.3.12 + type: DisplayString + help: Battery chemistry - 1.3.6.1.4.1.6574.4.3.12 + - name: upsBatteryProtection + oid: 1.3.6.1.4.1.6574.4.3.13 + type: DisplayString + help: Prevent deep discharge of battery - 1.3.6.1.4.1.6574.4.3.13 + - name: upsBatteryEnergySave + oid: 1.3.6.1.4.1.6574.4.3.14 + type: DisplayString + help: Switch off when running on battery and no/low load - 1.3.6.1.4.1.6574.4.3.14 + - name: upsInputVoltageValue + oid: 1.3.6.1.4.1.6574.4.4.1.1 + type: Float + help: Input voltage - 1.3.6.1.4.1.6574.4.4.1.1 + - name: upsInputVoltageMax + oid: 1.3.6.1.4.1.6574.4.4.1.2 + type: Float + help: Maximum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.2 + - name: upsInputVoltageMin + oid: 1.3.6.1.4.1.6574.4.4.1.3 + type: Float + help: Minimum incoming voltage seen - 1.3.6.1.4.1.6574.4.4.1.3 + - name: upsInputVoltageNominal + oid: 1.3.6.1.4.1.6574.4.4.1.4 + type: Float + help: Nominal input voltage - 1.3.6.1.4.1.6574.4.4.1.4 + - name: upsInputVoltageExtend + oid: 1.3.6.1.4.1.6574.4.4.1.5 + type: DisplayString + help: Extended input voltage range - 1.3.6.1.4.1.6574.4.4.1.5 + - name: upsInputVoltageFault + oid: 1.3.6.1.4.1.6574.4.4.1.6 + type: Float + help: Input voltage Fault - 1.3.6.1.4.1.6574.4.4.1.6 + - name: upsInputTransferReason + oid: 1.3.6.1.4.1.6574.4.4.2.1 + type: DisplayString + help: Reason for last transfer to battery - 1.3.6.1.4.1.6574.4.4.2.1 + - name: upsInputTransferLow + oid: 1.3.6.1.4.1.6574.4.4.2.2 + type: Float + help: Low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.2 + - name: upsInputTransferHigh + oid: 1.3.6.1.4.1.6574.4.4.2.3 + type: Float + help: High voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.3 + - name: upsInputTransferLowMin + oid: 1.3.6.1.4.1.6574.4.4.2.4 + type: Float + help: smallest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.4 + - name: upsInputTransferLowMax + oid: 1.3.6.1.4.1.6574.4.4.2.5 + type: Float + help: greatest settable low voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.5 + - name: upsInputTransferHighMin + oid: 1.3.6.1.4.1.6574.4.4.2.6 + type: Float + help: smallest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.6 + - name: upsInputTransferHighMax + oid: 1.3.6.1.4.1.6574.4.4.2.7 + type: Float + help: greatest settable high voltage transfer point - 1.3.6.1.4.1.6574.4.4.2.7 + - name: upsInputTransferBoostLow + oid: 1.3.6.1.4.1.6574.4.4.2.8 + type: Float + help: Low voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.8 + - name: upsInputTransferBoostHigh + oid: 1.3.6.1.4.1.6574.4.4.2.9 + type: Float + help: High voltage boosting transfer point - 1.3.6.1.4.1.6574.4.4.2.9 + - name: upsInputTransferTrimLow + oid: 1.3.6.1.4.1.6574.4.4.2.10 + type: Float + help: Low voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.10 + - name: upsInputTransferTrimHigh + oid: 1.3.6.1.4.1.6574.4.4.2.11 + type: Float + help: High voltage trimming transfer point - 1.3.6.1.4.1.6574.4.4.2.11 + - name: upsInputSensitivity + oid: 1.3.6.1.4.1.6574.4.4.3 + type: DisplayString + help: Input power sensitivity - 1.3.6.1.4.1.6574.4.4.3 + - name: upsInputQuality + oid: 1.3.6.1.4.1.6574.4.4.4 + type: DisplayString + help: Input power quality - 1.3.6.1.4.1.6574.4.4.4 + - name: upsInputCurrentValue + oid: 1.3.6.1.4.1.6574.4.4.5.1 + type: Float + help: Input current (A) - 1.3.6.1.4.1.6574.4.4.5.1 + - name: upsInputCurrentNominal + oid: 1.3.6.1.4.1.6574.4.4.5.2 + type: Float + help: Nominal input current (A) - 1.3.6.1.4.1.6574.4.4.5.2 + - name: upsInputFrequencyValue + oid: 1.3.6.1.4.1.6574.4.4.6.1 + type: Float + help: Input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.1 + - name: upsInputFrequencyNominal + oid: 1.3.6.1.4.1.6574.4.4.6.2 + type: Float + help: Nominal input line frequency (Hz) - 1.3.6.1.4.1.6574.4.4.6.2 + - name: upsInputFrequencyLow + oid: 1.3.6.1.4.1.6574.4.4.6.3 + type: Float + help: Input line frequency low (Hz) - 1.3.6.1.4.1.6574.4.4.6.3 + - name: upsInputFrequencyHigh + oid: 1.3.6.1.4.1.6574.4.4.6.4 + type: Float + help: Input line frequency high (Hz) - 1.3.6.1.4.1.6574.4.4.6.4 + - name: upsInputFrequencyExtend + oid: 1.3.6.1.4.1.6574.4.4.6.5 + type: DisplayString + help: Extended input frequency range - 1.3.6.1.4.1.6574.4.4.6.5 + - name: upsOutputVoltageValue + oid: 1.3.6.1.4.1.6574.4.5.1.1 + type: Float + help: Output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.1 + - name: upsOutputVoltageNominal + oid: 1.3.6.1.4.1.6574.4.5.1.2 + type: Float + help: Nominal output voltage (V) - 1.3.6.1.4.1.6574.4.5.1.2 + - name: upsOutputFrequencyValue + oid: 1.3.6.1.4.1.6574.4.5.2.1 + type: Float + help: Output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.1 + - name: upsOutputFrequencyNominal + oid: 1.3.6.1.4.1.6574.4.5.2.2 + type: Float + help: Nominal output frequency (Hz) - 1.3.6.1.4.1.6574.4.5.2.2 + - name: upsOutputCurrentValue + oid: 1.3.6.1.4.1.6574.4.5.3.1 + type: Float + help: Output current (A) - 1.3.6.1.4.1.6574.4.5.3.1 + - name: upsOutputCurrentNominal + oid: 1.3.6.1.4.1.6574.4.5.3.2 + type: Float + help: Nominal output current (A) - 1.3.6.1.4.1.6574.4.5.3.2 + - name: upsAmbientTemperatureValue + oid: 1.3.6.1.4.1.6574.4.6.1.1 + type: Float + help: Ambient temperature (degrees C) - 1.3.6.1.4.1.6574.4.6.1.1 + - name: upsAmbientTemperatureAlarm + oid: 1.3.6.1.4.1.6574.4.6.1.2 + type: DisplayString + help: Temperature alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.1.2 + - name: upsAmbientTemperatureHigh + oid: 1.3.6.1.4.1.6574.4.6.1.3 + type: Float + help: Temperature threshold high (degrees C) - 1.3.6.1.4.1.6574.4.6.1.3 + - name: upsAmbientTemperatureLow + oid: 1.3.6.1.4.1.6574.4.6.1.4 + type: Float + help: Temperature threshold low (degrees C) - 1.3.6.1.4.1.6574.4.6.1.4 + - name: upsAmbientTemperatureMax + oid: 1.3.6.1.4.1.6574.4.6.1.5 + type: Float + help: Maximum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.5 + - name: upsAmbientTemperatureMin + oid: 1.3.6.1.4.1.6574.4.6.1.6 + type: Float + help: Minimum temperature seen (degrees C) - 1.3.6.1.4.1.6574.4.6.1.6 + - name: upsAmbientHumidityValue + oid: 1.3.6.1.4.1.6574.4.6.2.1 + type: Float + help: Ambient relative humidity (percent) - 1.3.6.1.4.1.6574.4.6.2.1 + - name: upsAmbientHumidityAlarm + oid: 1.3.6.1.4.1.6574.4.6.2.2 + type: DisplayString + help: Relative humidity alarm (enabled/disabled) - 1.3.6.1.4.1.6574.4.6.2.2 + - name: upsAmbientHumidityHigh + oid: 1.3.6.1.4.1.6574.4.6.2.3 + type: Float + help: Relative humidity threshold high (percent) - 1.3.6.1.4.1.6574.4.6.2.3 + - name: upsAmbientHumidityLow + oid: 1.3.6.1.4.1.6574.4.6.2.4 + type: Float + help: Relative humidity threshold low (percent) - 1.3.6.1.4.1.6574.4.6.2.4 + - name: upsAmbientHumidityMax + oid: 1.3.6.1.4.1.6574.4.6.2.5 + type: Float + help: Maximum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.5 + - name: upsAmbientHumidityMin + oid: 1.3.6.1.4.1.6574.4.6.2.6 + type: Float + help: Minimum relative humidity seen (percent) - 1.3.6.1.4.1.6574.4.6.2.6 + - name: upsDriverName + oid: 1.3.6.1.4.1.6574.4.7.1 + type: DisplayString + help: Driver name - 1.3.6.1.4.1.6574.4.7.1 + - name: upsDriverVersion + oid: 1.3.6.1.4.1.6574.4.7.2 + type: DisplayString + help: Driver version (NUT release) - 1.3.6.1.4.1.6574.4.7.2 + - name: upsDriverVersionData + oid: 1.3.6.1.4.1.6574.4.7.3 + type: DisplayString + help: Driver version data - 1.3.6.1.4.1.6574.4.7.3 + - name: upsDriverVersionInternal + oid: 1.3.6.1.4.1.6574.4.7.4 + type: DisplayString + help: Internal driver version (if tracked separately) - 1.3.6.1.4.1.6574.4.7.4 + - name: upsDriverPollInterval + oid: 1.3.6.1.4.1.6574.4.7.5 + type: gauge + help: Poll interval setup in configuration file - 1.3.6.1.4.1.6574.4.7.5 + - name: upsDriverPort + oid: 1.3.6.1.4.1.6574.4.7.6 + type: DisplayString + help: Port setup in configuration file - 1.3.6.1.4.1.6574.4.7.6 + - name: upsDriverPollFrequency + oid: 1.3.6.1.4.1.6574.4.7.7 + type: gauge + help: Poll frequency - 1.3.6.1.4.1.6574.4.7.7 + - name: upsDriverProductID + oid: 1.3.6.1.4.1.6574.4.7.8 + type: DisplayString + help: Product ID - 1.3.6.1.4.1.6574.4.7.8 + - name: upsDriverSnmpVersion + oid: 1.3.6.1.4.1.6574.4.7.9 + type: DisplayString + help: Snmp version - 1.3.6.1.4.1.6574.4.7.9 + - name: upsServerInfo + oid: 1.3.6.1.4.1.6574.4.8.1 + type: DisplayString + help: Server information - 1.3.6.1.4.1.6574.4.8.1 + - name: upsServerVersion + oid: 1.3.6.1.4.1.6574.4.8.2 + type: DisplayString + help: Server version - 1.3.6.1.4.1.6574.4.8.2 + - name: diskSMARTInfoIndex + oid: 1.3.6.1.4.1.6574.5.1.1.1 + type: gauge + help: SMART info index - 1.3.6.1.4.1.6574.5.1.1.1 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTInfoDevName + oid: 1.3.6.1.4.1.6574.5.1.1.2 + type: DisplayString + help: SMART info device name - 1.3.6.1.4.1.6574.5.1.1.2 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrName + oid: 1.3.6.1.4.1.6574.5.1.1.3 + type: DisplayString + help: SMART attribute name - 1.3.6.1.4.1.6574.5.1.1.3 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrId + oid: 1.3.6.1.4.1.6574.5.1.1.4 + type: gauge + help: SMART attribute ID - 1.3.6.1.4.1.6574.5.1.1.4 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrCurrent + oid: 1.3.6.1.4.1.6574.5.1.1.5 + type: gauge + help: SMART attribute current value - 1.3.6.1.4.1.6574.5.1.1.5 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrWorst + oid: 1.3.6.1.4.1.6574.5.1.1.6 + type: gauge + help: SMART attribute worst value - 1.3.6.1.4.1.6574.5.1.1.6 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrThreshold + oid: 1.3.6.1.4.1.6574.5.1.1.7 + type: gauge + help: SMART attribute threshold value - 1.3.6.1.4.1.6574.5.1.1.7 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrRaw + oid: 1.3.6.1.4.1.6574.5.1.1.8 + type: gauge + help: SMART attribute raw value - 1.3.6.1.4.1.6574.5.1.1.8 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrStatus + oid: 1.3.6.1.4.1.6574.5.1.1.9 + type: DisplayString + help: SMART attribute status - 1.3.6.1.4.1.6574.5.1.1.9 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: diskSMARTAttrRaw64 + oid: 1.3.6.1.4.1.6574.5.1.1.10 + type: counter + help: SMART attribute raw value with 64-bit capacity - 1.3.6.1.4.1.6574.5.1.1.10 + indexes: + - labelname: diskSMARTInfoIndex + type: gauge + - name: serviceInfoIndex + oid: 1.3.6.1.4.1.6574.6.1.1.1 + type: gauge + help: Service info index - 1.3.6.1.4.1.6574.6.1.1.1 + indexes: + - labelname: serviceInfoIndex + type: gauge + lookups: + - labels: + - serviceInfoIndex + labelname: serviceName + oid: 1.3.6.1.4.1.6574.6.1.1.2 + type: DisplayString + - labels: [] + labelname: serviceInfoIndex + - name: serviceName + oid: 1.3.6.1.4.1.6574.6.1.1.2 + type: DisplayString + help: Service name - 1.3.6.1.4.1.6574.6.1.1.2 + indexes: + - labelname: serviceInfoIndex + type: gauge + lookups: + - labels: + - serviceInfoIndex + labelname: serviceName + oid: 1.3.6.1.4.1.6574.6.1.1.2 + type: DisplayString + - labels: [] + labelname: serviceInfoIndex + - name: serviceUsers + oid: 1.3.6.1.4.1.6574.6.1.1.3 + type: gauge + help: Number of users using this service - 1.3.6.1.4.1.6574.6.1.1.3 + indexes: + - labelname: serviceInfoIndex + type: gauge + lookups: + - labels: + - serviceInfoIndex + labelname: serviceName + oid: 1.3.6.1.4.1.6574.6.1.1.2 + type: DisplayString + - labels: [] + labelname: serviceInfoIndex + printer_mib: + walk: + - 1.3.6.1.2.1.43.10.2.1.4 + - 1.3.6.1.2.1.43.10.2.1.5 + - 1.3.6.1.2.1.43.11.1.1.5 + - 1.3.6.1.2.1.43.11.1.1.6 + - 1.3.6.1.2.1.43.11.1.1.8 + - 1.3.6.1.2.1.43.11.1.1.9 + - 1.3.6.1.2.1.43.5.1.1.13 + - 1.3.6.1.2.1.43.5.1.1.16 + - 1.3.6.1.2.1.43.5.1.1.17 + - 1.3.6.1.2.1.43.5.1.1.18 + - 1.3.6.1.2.1.43.5.1.1.19 + - 1.3.6.1.2.1.43.5.1.1.3 + - 1.3.6.1.2.1.43.6.1.1.3 + metrics: + - name: prtMarkerLifeCount + oid: 1.3.6.1.2.1.43.10.2.1.4 + type: counter + help: The count of the number of units of measure counted during the life of printer using units of measure as specified by prtMarkerCounterUnit - 1.3.6.1.2.1.43.10.2.1.4 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerIndex + type: gauge + - name: prtMarkerPowerOnCount + oid: 1.3.6.1.2.1.43.10.2.1.5 + type: counter + help: The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by prtMarkerCounterUnit. - 1.3.6.1.2.1.43.10.2.1.5 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerIndex + type: gauge + - name: prtMarkerSuppliesType + oid: 1.3.6.1.2.1.43.11.1.1.5 + type: gauge + help: The type of this supply. - 1.3.6.1.2.1.43.11.1.1.5 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerSuppliesIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesType + oid: 1.3.6.1.2.1.43.11.1.1.5 + type: gauge + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesDescription + oid: 1.3.6.1.2.1.43.11.1.1.6 + type: DisplayString + enum_values: + 1: other + 2: unknown + 3: toner + 4: wasteToner + 5: ink + 6: inkCartridge + 7: inkRibbon + 8: wasteInk + 9: opc + 10: developer + 11: fuserOil + 12: solidWax + 13: ribbonWax + 14: wasteWax + 15: fuser + 16: coronaWire + 17: fuserOilWick + 18: cleanerUnit + 19: fuserCleaningPad + 20: transferUnit + 21: tonerCartridge + 22: fuserOiler + 23: water + 24: wasteWater + 25: glueWaterAdditive + 26: wastePaper + 27: bindingSupply + 28: bandingSupply + 29: stitchingWire + 30: shrinkWrap + 31: paperWrap + 32: staples + 33: inserts + 34: covers + 35: matteToner + 36: matteInk + - name: prtMarkerSuppliesDescription + oid: 1.3.6.1.2.1.43.11.1.1.6 + type: DisplayString + help: The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. - 1.3.6.1.2.1.43.11.1.1.6 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerSuppliesIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesType + oid: 1.3.6.1.2.1.43.11.1.1.5 + type: gauge + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesDescription + oid: 1.3.6.1.2.1.43.11.1.1.6 + type: DisplayString + - name: prtMarkerSuppliesMaxCapacity + oid: 1.3.6.1.2.1.43.11.1.1.8 + type: gauge + help: The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit - 1.3.6.1.2.1.43.11.1.1.8 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerSuppliesIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesType + oid: 1.3.6.1.2.1.43.11.1.1.5 + type: gauge + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesDescription + oid: 1.3.6.1.2.1.43.11.1.1.6 + type: DisplayString + - name: prtMarkerSuppliesLevel + oid: 1.3.6.1.2.1.43.11.1.1.9 + type: gauge + help: The current level if this supply is a container; the remaining space if this supply is a receptacle - 1.3.6.1.2.1.43.11.1.1.9 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtMarkerSuppliesIndex + type: gauge + lookups: + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesType + oid: 1.3.6.1.2.1.43.11.1.1.5 + type: gauge + - labels: + - hrDeviceIndex + - prtMarkerSuppliesIndex + labelname: prtMarkerSuppliesDescription + oid: 1.3.6.1.2.1.43.11.1.1.6 + type: DisplayString + - name: prtConsoleDisable + oid: 1.3.6.1.2.1.43.5.1.1.13 + type: EnumAsStateSet + help: This value indicates how input is (or is not) accepted from the operator console - 1.3.6.1.2.1.43.5.1.1.13 + indexes: + - labelname: hrDeviceIndex + type: gauge + enum_values: + 3: enabled + 4: disabled + - name: prtGeneralPrinterName + oid: 1.3.6.1.2.1.43.5.1.1.16 + type: DisplayString + help: An administrator-specified name for this printer - 1.3.6.1.2.1.43.5.1.1.16 + indexes: + - labelname: hrDeviceIndex + type: gauge + - name: prtGeneralSerialNumber + oid: 1.3.6.1.2.1.43.5.1.1.17 + type: DisplayString + help: A recorded serial number for this device that indexes some type device catalog or inventory - 1.3.6.1.2.1.43.5.1.1.17 + indexes: + - labelname: hrDeviceIndex + type: gauge + - name: prtAlertCriticalEvents + oid: 1.3.6.1.2.1.43.5.1.1.18 + type: counter + help: A running counter of the number of critical alert events that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.18 + indexes: + - labelname: hrDeviceIndex + type: gauge + - name: prtAlertAllEvents + oid: 1.3.6.1.2.1.43.5.1.1.19 + type: counter + help: A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.19 + indexes: + - labelname: hrDeviceIndex + type: gauge + - name: prtGeneralReset + oid: 1.3.6.1.2.1.43.5.1.1.3 + type: EnumAsStateSet + help: Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults' will result in the resetting of the printer - 1.3.6.1.2.1.43.5.1.1.3 + indexes: + - labelname: hrDeviceIndex + type: gauge + enum_values: + 3: notResetting + 4: powerCycleReset + 5: resetToNVRAM + 6: resetToFactoryDefaults + - name: prtCoverStatus + oid: 1.3.6.1.2.1.43.6.1.1.3 + type: EnumAsStateSet + help: The status of this cover sub-unit. - 1.3.6.1.2.1.43.6.1.1.3 + indexes: + - labelname: hrDeviceIndex + type: gauge + - labelname: prtCoverIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: coverOpen + 4: coverClosed + 5: interlockOpen + 6: interlockClosed + dell: + walk: + - 1.3.6.1.4.1.674.10892.5.2 + - 1.3.6.1.4.1.674.10892.5.4 + - 1.3.6.1.4.1.674.10892.5.5 + metrics: + - name: globalSystemStatus + oid: 1.3.6.1.4.1.674.10892.5.2.1 + type: gauge + help: This attribute defines the overall rollup status of all components in the system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1 + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemLCDStatus + oid: 1.3.6.1.4.1.674.10892.5.2.2 + type: gauge + help: This attribute defines the system status as it is reflected by the LCD front panel - 1.3.6.1.4.1.674.10892.5.2.2 + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: globalStorageStatus + oid: 1.3.6.1.4.1.674.10892.5.2.3 + type: gauge + help: This attribute defines the overall storage status being monitored by the remote access card. - 1.3.6.1.4.1.674.10892.5.2.3 + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemPowerState + oid: 1.3.6.1.4.1.674.10892.5.2.4 + type: gauge + help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4 + enum_values: + 1: other + 2: unknown + 3: "off" + 4: "on" + - name: systemPowerUpTime + oid: 1.3.6.1.4.1.674.10892.5.2.5 + type: gauge + help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5 + - name: mIBMajorVersionNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1.1 + type: gauge + help: 0001.0001 This attribute defines the major version number for the version of this MIB supported by the iDRAC. - 1.3.6.1.4.1.674.10892.5.4.1.1 + - name: mIBMinorVersionNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1.2 + type: gauge + help: 0001.0002 This attribute defines the minor version number for the version of this MIB supported by the iDRAC. - 1.3.6.1.4.1.674.10892.5.4.1.2 + - name: mIBMaintenanceVersionNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1.3 + type: gauge + help: 0001.0003 This attribute defines the maintenance version number for the version of this MIB supported by the iDRAC. - 1.3.6.1.4.1.674.10892.5.4.1.3 + - name: systemStatechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 + type: gauge + help: 0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateGlobalSystemStatus + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 + type: gauge + help: 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateChassisState + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 + type: gauge + help: 0200.0010.0001.0003 This attribute defines the state settings of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: systemStateChassisStatus + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 + type: gauge + help: 0200.0010.0001.0004 This attribute defines the status of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStatePowerUnitStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 + type: OctetString + help: 0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStatePowerUnitStatusRedundancy + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 + type: gauge + help: 0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: full + 4: degraded + 5: lost + 6: notRedundant + 7: redundancyOffline + - name: systemStatePowerUnitStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 + type: OctetString + help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStatePowerSupplyStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 + type: OctetString + help: 0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStatePowerSupplyStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 + type: gauge + help: 0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStatePowerSupplyStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 + type: OctetString + help: 0200.0010.0001.0010 This attribute lists the status of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateVoltageStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 + type: OctetString + help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateVoltageStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 + type: gauge + help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateVoltageStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 + type: OctetString + help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateAmperageStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 + type: OctetString + help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateAmperageStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 + type: gauge + help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateAmperageStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 + type: OctetString + help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCoolingUnitStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 + type: OctetString + help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCoolingUnitStatusRedundancy + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 + type: gauge + help: 0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: full + 4: degraded + 5: lost + 6: notRedundant + 7: redundancyOffline + - name: systemStateCoolingUnitStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 + type: OctetString + help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCoolingDeviceStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 + type: OctetString + help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCoolingDeviceStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 + type: gauge + help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateCoolingDeviceStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 + type: OctetString + help: 0200.0010.0001.0022 This attribute lists the status of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateTemperatureStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 + type: OctetString + help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateTemperatureStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 + type: gauge + help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateTemperatureStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 + type: OctetString + help: 0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateMemoryDeviceStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 + type: OctetString + help: 0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateMemoryDeviceStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 + type: gauge + help: 0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateMemoryDeviceStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 + type: OctetString + help: 0200.0010.0001.0028 This attribute lists the status of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateChassisIntrusionStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 + type: OctetString + help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateChassisIntrusionStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 + type: gauge + help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateChassisIntrusionStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 + type: OctetString + help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStatePowerUnitStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 + type: gauge + help: 0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStatePowerUnitStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 + type: OctetString + help: 0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCoolingUnitStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 + type: gauge + help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateCoolingUnitStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 + type: OctetString + help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateProcessorDeviceStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 + type: gauge + help: 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateProcessorDeviceStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 + type: OctetString + help: 0200.0010.0001.0051 This attribute lists the status of each processor device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateBatteryStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 + type: gauge + help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateBatteryStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 + type: OctetString + help: 0200.0010.0001.0053 This attribute lists the status of each battery of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateSDCardUnitStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 + type: gauge + help: 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateSDCardUnitStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 + type: OctetString + help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateSDCardDeviceStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 + type: gauge + help: 0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateSDCardDeviceStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 + type: OctetString + help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateIDSDMCardUnitStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 + type: gauge + help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateIDSDMCardUnitStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 + type: OctetString + help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateIDSDMCardDeviceStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 + type: gauge + help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateIDSDMCardDeviceStatusList + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 + type: OctetString + help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateTemperatureStatisticsStateDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 + type: OctetString + help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateTemperatureStatisticsStatusCombined + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 + type: gauge + help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemStateTemperatureStatisticsStatusDetails + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 + type: OctetString + help: 0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 + indexes: + - labelname: systemStatechassisIndex + type: gauge + - name: systemStateCMCStatus + oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 + type: gauge + help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 + indexes: + - labelname: systemStatechassisIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: numEventLogEntries + oid: 1.3.6.1.4.1.674.10892.5.4.300.1 + type: gauge + help: 0300.0001.0000 This attribute provides the number of entries currently in the eventLogTable. - 1.3.6.1.4.1.674.10892.5.4.300.1 + - name: numLCLogEntries + oid: 1.3.6.1.4.1.674.10892.5.4.300.2 + type: gauge + help: 0300.0002.0000 This attribute provides the number of entries currently in the lcLogTable - 1.3.6.1.4.1.674.10892.5.4.300.2 + - name: chassisIndexChassisInformation + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.1 + type: gauge + help: 0300.0010.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.1 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.2 + type: gauge + help: 0300.0010.0001.0002 This attribute defines the state capabilities of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.2 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: chassisStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.3 + type: gauge + help: 0300.0010.0001.0003 This attribute defines the state settings of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.3 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: chassisStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.4 + type: gauge + help: 0300.0010.0001.0004 This attribute defines the status of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.4 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: chassisparentIndexReference + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.5 + type: gauge + help: 0300.0010.0001.0005 This attribute defines the index (one based) to the parent system of this system chassis, if any. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.5 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisType + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.6 + type: gauge + help: 0300.0010.0001.0006 This attribute defines the system type of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.6 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: other + 2: unknown + 3: desktop + 4: lowProfileDesktop + 5: pizzaBox + 6: miniTower + 7: tower + 8: portable + 9: lapTop + 10: noteBook + 11: handHeld + 12: dockingStation + 13: allInOne + 14: subNoteBook + 15: spaceSaving + 16: lunchBox + 17: mainSystemChassis + 18: expansionChassis + 19: subChassis + 20: busExpansionChassis + 21: peripheralChassis + 22: raidChassis + 23: rackMountChassis + 24: sealedCasePC + 25: multiSystemChassis + - name: chassisName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.7 + type: OctetString + help: 0300.0010.0001.0007 This attribute defines the user-assigned name of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.7 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.8 + type: OctetString + help: 0300.0010.0001.0008 This attribute defines the name of the manufacturer of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.8 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisModelTypeName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.9 + type: OctetString + help: 0300.0010.0001.0009 This attribute defines the system model type of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.9 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisAssetTagName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.10 + type: OctetString + help: 0300.0010.0001.0010 This attribute defines the asset tag name of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.10 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisServiceTagName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.11 + type: OctetString + help: 0300.0010.0001.0011 This attribute defines the service tag name of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.11 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisID + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.12 + type: gauge + help: 0300.0010.0001.0012 This attribute defines the system ID - 1.3.6.1.4.1.674.10892.5.4.300.10.1.12 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisIDExtension + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.13 + type: gauge + help: 0300.0010.0001.0013 This attribute defines the system ID extension. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.13 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisSystemClass + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.14 + type: gauge + help: 0300.0010.0001.0014 This attribute defines the system class. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.14 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: other + 2: unknown + 3: workstationClass + 4: serverClass + 5: desktopClass + 6: portableClass + 7: netPCClass + 8: storageClass + - name: chassisSystemName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.15 + type: OctetString + help: 0300.0010.0001.0015 This attribute defines the host name of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.15 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisLEDControlCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.24 + type: gauge + help: 0300.0010.0001.0024 This attribute defines the capabilities of the LED control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.24 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: alertOnErrorCapable + 4: alertOnWarningAndErrorCapable + 6: alertOnWarningOrErrorCapable + - name: chassisLEDControlSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.25 + type: gauge + help: 0300.0010.0001.0025 This attribute defines the reading and setting of the LED control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.25 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: alertOnError + 4: alertOnWarningAndError + - name: chassisIdentifyFlashControlCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.28 + type: gauge + help: 0300.0010.0001.0028 This attribute defines if the system allows setting of the system front panel LED to flash. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.28 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 8: identifyCapable + - name: chassisIdentifyFlashControlSettings + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.29 + type: gauge + help: 0300.0010.0001.0029 This attribute setting causes the system front panel LED to flash. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.29 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 8: identifyChassis + 10: identifyChassisAndEnable + - name: chassisLockPresent + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.30 + type: gauge + help: 0300.0010.0001.0030 If true, a system lock is present on the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.30 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassishostControlCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.31 + type: gauge + help: 0300.0010.0001.0031 This attribute defines the capabilities of the host control function. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.31 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: manualRebootCapable + 2: manualPowerOFFCapable + 4: manualPowerCycleCapable + 7: manualAllExceptOperatingSystemShutdownCapable + 8: manualOperatingSystemShutdownCapable + 15: manualFullyCapable + 16: manualRebootWithOSShutdownCapable + 32: manualRebootWithoutOSShutdownCapable + 64: manualPowerOffWithOSShutdownCapable + 128: manualPowerOffWithoutOSShutdownCapable + 256: manualPowerCycleWithOSShutdownCapable + 512: manualPowerCycleWithoutOSShutdownCapable + - name: chassishostControlSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.32 + type: gauge + help: 0300.0010.0001.0032 This attribute defines the settings of the host control function. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.32 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: manualReboot + 2: manualPowerOFF + 4: manualPowerCycle + 8: manualOperatingSystemShutdown + 9: manualOperatingSystemShutdownThenReboot + 10: manualOperatingSystemShutdownThenPowerOFF + 12: manualOperatingSystemShutdownThenPowerCycle + - name: chassiswatchDogControlCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.33 + type: gauge + help: 0300.0010.0001.0033 This attribute defines the capabilities of the watchdog control function. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.33 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: automaticRebootCapable + 2: automaticPowerCycleCapable + 4: automaticNotificationCapable + 8: automaticWatchDogTimerCapable + 16: automaticPowerOffCapable + 27: automaticAllExceptNotificationCapable + 31: automaticFullyCapable + - name: chassiswatchDogControlSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.34 + type: gauge + help: 0300.0010.0001.0034 This attribute defines the settings of the watchdog control function. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.34 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: automaticRebootEnabled + 2: automaticPowerCycleEnabled + 4: automaticNotificationEnabled + 8: automaticPowerOffEnabled + - name: chassiswatchDogControlExpiryTimeCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.35 + type: gauge + help: 0300.0010.0001.0035 This attribute defines the capabilities of the watchdog control expiry timer function. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.35 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: type1Capable + 2: type2Capable + 4: type3Capable + - name: chassiswatchDogControlExpiryTime + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.36 + type: gauge + help: 0300.0010.0001.0036 This attribute defines the current watchdog timer value in seconds. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.36 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisPowerButtonControlCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.38 + type: gauge + help: 0300.0010.0001.0038 This attribute defines the capabilities of the power button control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.38 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + - name: chassisPowerButtonControlSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.39 + type: gauge + help: 0300.0010.0001.0039 This attribute defines the reading and setting of the power button control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.39 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: disabled + - name: chassisNMIButtonControlCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.44 + type: gauge + help: 0300.0010.0001.0044 This attribute defines the capabilities of the NMI button control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.44 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + - name: chassisNMIButtonControlSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.45 + type: gauge + help: 0300.0010.0001.0045 This attribute defines the reading and setting of the NMI button control hardware in the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.45 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: disabled + - name: chassisSystemProperties + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.46 + type: gauge + help: 0300.0010.0001.0046 This attribute defines the properties of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.46 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + enum_values: + 1: energySmart + - name: chassisSystemRevisionNumber + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.47 + type: gauge + help: 0300.0010.0001.0047 This attribute defines the revision number of the system where zero indicates the original version of the system chassis - 1.3.6.1.4.1.674.10892.5.4.300.10.1.47 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisSystemRevisionName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.48 + type: OctetString + help: 0300.0010.0001.0048 This attribute defines the revision name of the system, if applicable. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.48 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: chassisExpressServiceCodeName + oid: 1.3.6.1.4.1.674.10892.5.4.300.10.1.49 + type: OctetString + help: 0300.0010.0001.0049 This attribute defines the Express Service Code of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.10.1.49 + indexes: + - labelname: chassisIndexChassisInformation + type: gauge + - name: eventLogchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.1 + type: gauge + help: 0300.0040.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.1 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + - name: eventLogRecordIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.2 + type: gauge + help: 0300.0040.0001.0002 This attribute defines the index (one based) of the event log record. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.2 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + - name: eventLogStateCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.3 + type: gauge + help: 0300.0040.0001.0003 This attribute defines the state capabilities of the object that is writing the event log. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.3 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + enum_values: + 1: unknown + 2: onlineCapable + 4: notReadyCapable + 8: resetCapable + - name: eventLogStateSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.4 + type: gauge + help: 0300.0040.0001.0004 This attribute defines the state settings of the object that is writing the event log. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.4 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + enum_values: + 1: unknown + 2: online + 4: notReady + 8: reset + - name: eventLogRecord + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.5 + type: OctetString + help: 0300.0040.0001.0005 This attribute defines the data of the event log record. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.5 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + - name: eventLogFormat + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.6 + type: gauge + help: 0300.0040.0001.0006 This attribute defines the format of the event log record. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.6 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + enum_values: + 1: raw + 2: ascii + 3: uniCode + - name: eventLogSeverityStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.7 + type: gauge + help: 0300.0040.0001.0007 This attribute defines the severity of the event log record. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.7 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: eventLogDateName + oid: 1.3.6.1.4.1.674.10892.5.4.300.40.1.8 + type: OctetString + help: 0300.0040.0001.0008 This attribute defines the date and time of the event log record. - 1.3.6.1.4.1.674.10892.5.4.300.40.1.8 + indexes: + - labelname: eventLogchassisIndex + type: gauge + - labelname: eventLogRecordIndex + type: gauge + - name: systemBIOSchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.1 + type: gauge + help: 0300.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.1 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + - name: systemBIOSIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.2 + type: gauge + help: 0300.0050.0001.0002 This attribute defines the index (one based) of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.2 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + - name: systemBIOSStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.3 + type: gauge + help: 0300.0050.0001.0003 This attribute defines the state capabilities of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.3 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: systemBIOSStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.4 + type: gauge + help: 0300.0050.0001.0004 This attribute defines the state settings of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.4 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: systemBIOSStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 + type: gauge + help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemBIOSReleaseDateName + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.7 + type: OctetString + help: 0300.0050.0001.0007 This attribute defines the release date name of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.7 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + - name: systemBIOSVersionName + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.8 + type: OctetString + help: 0300.0050.0001.0008 This attribute defines the version name of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.8 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + - name: systemBIOSManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.11 + type: OctetString + help: 0300.0050.0001.0011 This attribute defines the name of the manufacturer of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.11 + indexes: + - labelname: systemBIOSchassisIndex + type: gauge + - labelname: systemBIOSIndex + type: gauge + - name: firmwarechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.1 + type: gauge + help: 0300.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.1 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: firmwareIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.2 + type: gauge + help: 0300.0060.0001.0002 This attribute defines the index (one based) of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.2 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: firmwareStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.3 + type: gauge + help: 0300.0060.0001.0003 This attribute defines the state capabilities of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.3 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: firmwareStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.4 + type: gauge + help: 0300.0060.0001.0004 This attribute defines the state settings of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.4 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: firmwareStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.5 + type: gauge + help: 0300.0060.0001.0005 This attribute defines the status of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.5 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: firmwareSize + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.6 + type: gauge + help: 0300.0060.0001.0006 This attribute defines the image size of the firmware in KBytes - 1.3.6.1.4.1.674.10892.5.4.300.60.1.6 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: firmwareType + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.7 + type: gauge + help: 0300.0060.0001.0007 This attribute defines the type of firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.7 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + enum_values: + 1: other + 2: unknown + 20: lifecycleController + 21: iDRAC7 + 22: iDRAC8 + 23: iDRAC9 + - name: firmwareTypeName + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.8 + type: OctetString + help: 0300.0060.0001.0008 This attribute defines the type name of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.8 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: firmwareUpdateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.9 + type: gauge + help: 0300.0060.0001.0009 This attribute defines the bitmap of supported methods for firmware update. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.9 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: firmwareVersionName + oid: 1.3.6.1.4.1.674.10892.5.4.300.60.1.11 + type: OctetString + help: 0300.0060.0001.0011 This attribute defines the version of the firmware. - 1.3.6.1.4.1.674.10892.5.4.300.60.1.11 + indexes: + - labelname: firmwarechassisIndex + type: gauge + - labelname: firmwareIndex + type: gauge + - name: intrusionchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.1 + type: gauge + help: 0300.0070.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.1 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + - name: intrusionIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.2 + type: gauge + help: 0300.0070.0001.0002 This attribute defines the index (one based) of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.2 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + - name: intrusionStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.3 + type: gauge + help: 0300.0070.0001.0003 This attribute defines the state capabilities of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.3 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: intrusionStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.4 + type: gauge + help: 0300.0070.0001.0004 This attribute defines the state settings of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.4 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: intrusionStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 + type: gauge + help: 0300.0070.0001.0005 This attribute defines the status of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: intrusionReading + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 + type: gauge + help: 0300.0070.0001.0006 This attribute defines the reading of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + enum_values: + 1: chassisNotBreached + 2: chassisBreached + 3: chassisBreachedPrior + 4: chassisBreachSensorFailure + - name: intrusionType + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.7 + type: gauge + help: 0300.0070.0001.0007 This attribute defines the type of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.7 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + enum_values: + 1: chassisBreachDetectionWhenPowerON + 2: chassisBreachDetectionWhenPowerOFF + - name: intrusionLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.300.70.1.8 + type: OctetString + help: 0300.0070.0001.0008 This attribute defines the location of the intrusion sensor. - 1.3.6.1.4.1.674.10892.5.4.300.70.1.8 + indexes: + - labelname: intrusionchassisIndex + type: gauge + - labelname: intrusionIndex + type: gauge + - name: lcLogChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.1 + type: gauge + help: 0300.0090.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.1 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogRecordIndex + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.2 + type: gauge + help: 0300.0090.0001.0002 This attribute defines the index (one based) of the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.2 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogSequenceNumber + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.3 + type: gauge + help: 0300.0090.0001.0003 This attribute defines the LC Log sequence number of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.3 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogCategory + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.4 + type: gauge + help: 0300.0090.0001.0004 This attribute defines the category of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.4 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + enum_values: + 1: system + 2: storage + 3: updates + 4: audit + 5: configuration + 6: workNotes + - name: lcLogSeverityStatus + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.5 + type: gauge + help: 0300.0090.0001.0005 This attribute defines the severity of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.5 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: lcLogDateName + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.6 + type: OctetString + help: 0300.0090.0001.0006 This attribute defines the date and time of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.6 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.7 + type: OctetString + help: 0300.0090.0001.0007 Fully qualified device descriptor (FQDD) of the device associated with the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.7 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogMessageID + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.8 + type: OctetString + help: 0300.0090.0001.0008 This attribute defines the Message ID of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.8 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogMessage + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.9 + type: OctetString + help: 0300.0090.0001.0009 This attribute defines the message of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.9 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogDetailedDescription + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.10 + type: OctetString + help: 0300.0090.0001.0010 This attribute defines the detailed description of the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.10 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogRecommededAction + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.11 + type: OctetString + help: 0300.0090.0001.0011 This attribute defines an optional recommended action associated with the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.11 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: lcLogComment + oid: 1.3.6.1.4.1.674.10892.5.4.300.90.1.12 + type: OctetString + help: 0300.0090.0001.0012 This attribute defines an optional user comment associated with the event associated with the LC log record. - 1.3.6.1.4.1.674.10892.5.4.300.90.1.12 + indexes: + - labelname: lcLogChassisIndex + type: gauge + - labelname: lcLogRecordIndex + type: gauge + - name: powerUnitchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.1 + type: gauge + help: 0600.0010.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.1 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + - name: powerUnitIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.2 + type: gauge + help: 0600.0010.0001.0002 This attribute defines the index (one based) of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.2 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + - name: powerUnitStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.3 + type: gauge + help: 0600.0010.0001.0003 This attribute defines the state capabilities of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.3 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: powerUnitStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.4 + type: gauge + help: 0600.0010.0001.0004 This attribute defines the state settings of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.4 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: powerUnitRedundancyStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.5 + type: gauge + help: 0600.0010.0001.0005 This attribute defines the redundancy status of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.5 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: full + 4: degraded + 5: lost + 6: notRedundant + 7: redundancyOffline + - name: powerSupplyCountForRedundancy + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.6 + type: gauge + help: 0600.0010.0001.0006 This attribute defines the total number of power supplies required for this power unit to have full redundancy. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.6 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + - name: powerUnitName + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.7 + type: OctetString + help: 0600.0010.0001.0007 This attribute defines the name of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.7 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + - name: powerUnitStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.10.1.8 + type: gauge + help: 0600.0010.0001.0008 This attribute defines the status of the power unit. - 1.3.6.1.4.1.674.10892.5.4.600.10.1.8 + indexes: + - labelname: powerUnitchassisIndex + type: gauge + - labelname: powerUnitIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: powerSupplychassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 + type: gauge + help: 0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 + type: gauge + help: 0600.0012.0001.0002 This attribute defines the index (one based) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyStateCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 + type: gauge + help: 0600.0012.0001.0003 This attribute defines the state capabilities of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: unknown + 2: onlineCapable + 4: notReadyCapable + - name: powerSupplyStateSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 + type: gauge + help: 0600.0012.0001.0004 This attribute defines the state settings of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: unknown + 2: onLine + 4: notReady + 8: fanFailure + 10: onlineAndFanFailure + 16: powerSupplyIsON + 32: powerSupplyIsOK + 64: acSwitchIsON + 66: onlineandAcSwitchIsON + 128: acPowerIsON + 130: onlineAndAcPowerIsON + 210: onlineAndPredictiveFailure + 242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline + - name: powerSupplyStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 + type: gauge + help: 0600.0012.0001.0005 This attribute defines the status of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: powerSupplyOutputWatts + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 + type: gauge + help: 0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyType + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 + type: gauge + help: 0600.0012.0001.0007 This attribute defines the type of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: powerSupplyTypeIsOther + 2: powerSupplyTypeIsUnknown + 3: powerSupplyTypeIsLinear + 4: powerSupplyTypeIsSwitching + 5: powerSupplyTypeIsBattery + 6: powerSupplyTypeIsUPS + 7: powerSupplyTypeIsConverter + 8: powerSupplyTypeIsRegulator + 9: powerSupplyTypeIsAC + 10: powerSupplyTypeIsDC + 11: powerSupplyTypeIsVRM + - name: powerSupplyLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 + type: OctetString + help: 0600.0012.0001.0008 This attribute defines the location of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyMaximumInputVoltage + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 + type: gauge + help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplypowerUnitIndexReference + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 + type: gauge + help: 0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplySensorState + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 + type: gauge + help: 0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: presenceDetected + 2: psFailureDetected + 4: predictiveFailure + 8: psACLost + 16: acLostOrOutOfRange + 32: acOutOfRangeButPresent + 64: configurationError + - name: powerSupplyConfigurationErrorType + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 + type: gauge + help: 0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + enum_values: + 1: vendorMismatch + 2: revisionMismatch + 3: processorMissing + - name: powerSupplyPowerMonitorCapable + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 + type: gauge + help: 0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyRatedInputWattage + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 + type: gauge + help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 + type: OctetString + help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: powerSupplyCurrentInputVoltage + oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 + type: gauge + help: 0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 + indexes: + - labelname: powerSupplychassisIndex + type: gauge + - labelname: powerSupplyIndex + type: gauge + - name: voltageProbechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.1 + type: gauge + help: 0600.0020.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.1 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.2 + type: gauge + help: 0600.0020.0001.0002 This attribute defines the index (one based) of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.2 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 + type: gauge + help: 0600.0020.0001.0003 This attribute defines the state capabilities of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: voltageProbeStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.4 + type: gauge + help: 0600.0020.0001.0004 This attribute defines the state settings of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.4 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: voltageProbeStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5 + type: gauge + help: 0600.0020.0001.0005 This attribute defines the probe status of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.5 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCriticalUpper + 5: criticalUpper + 6: nonRecoverableUpper + 7: nonCriticalLower + 8: criticalLower + 9: nonRecoverableLower + 10: failed + - name: voltageProbeReading + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6 + type: gauge + help: 0600.0020.0001.0006 This attribute defines the reading for a voltage probe of type other than voltageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.20.1.6 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeType + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.7 + type: gauge + help: 0600.0020.0001.0007 This attribute defines the type of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.7 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: voltageProbeTypeIsOther + 2: voltageProbeTypeIsUnknown + 3: voltageProbeTypeIs1Point5Volt + 4: voltageProbeTypeIs3Point3Volt + 5: voltageProbeTypeIs5Volt + 6: voltageProbeTypeIsMinus5Volt + 7: voltageProbeTypeIs12Volt + 8: voltageProbeTypeIsMinus12Volt + 9: voltageProbeTypeIsIO + 10: voltageProbeTypeIsCore + 11: voltageProbeTypeIsFLEA + 12: voltageProbeTypeIsBattery + 13: voltageProbeTypeIsTerminator + 14: voltageProbeTypeIs2Point5Volt + 15: voltageProbeTypeIsGTL + 16: voltageProbeTypeIsDiscrete + 17: voltageProbeTypeIsGenericDiscrete + 18: voltageProbeTypeIsPSVoltage + 19: voltageProbeTypeIsMemoryStatus + - name: voltageProbeLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.8 + type: OctetString + help: 0600.0020.0001.0008 This attribute defines the location name of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.8 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeUpperNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 + type: gauge + help: 0600.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeUpperCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.10 + type: gauge + help: 0600.0020.0001.0010 This attribute defines the upper critical threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.10 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeUpperNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.11 + type: gauge + help: 0600.0020.0001.0011 This attribute defines the upper noncritical threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.11 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeLowerNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.12 + type: gauge + help: 0600.0020.0001.0012 This attribute defines the lower noncritical threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.12 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeLowerCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.13 + type: gauge + help: 0600.0020.0001.0013 This attribute defines the lower critical threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.13 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeLowerNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 + type: gauge + help: 0600.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the voltage probe - 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + - name: voltageProbeProbeCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.15 + type: gauge + help: 0600.0020.0001.0015 This attribute defines the probe capabilities of the voltage probe. - 1.3.6.1.4.1.674.10892.5.4.600.20.1.15 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: upperNonCriticalThresholdSetCapable + 2: lowerNonCriticalThresholdSetCapable + 4: upperNonCriticalThresholdDefaultCapable + 8: lowerNonCriticalThresholdDefaultCapable + - name: voltageProbeDiscreteReading + oid: 1.3.6.1.4.1.674.10892.5.4.600.20.1.16 + type: gauge + help: 0600.0020.0001.0016 This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.20.1.16 + indexes: + - labelname: voltageProbechassisIndex + type: gauge + - labelname: voltageProbeIndex + type: gauge + enum_values: + 1: voltageIsGood + 2: voltageIsBad + - name: amperageProbechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.1 + type: gauge + help: 0600.0030.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.1 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.2 + type: gauge + help: 0600.0030.0001.0002 This attribute defines the index (one based) of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.2 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.3 + type: gauge + help: 0600.0030.0001.0003 This attribute defines the state capabilities of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.3 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: amperageProbeStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.4 + type: gauge + help: 0600.0030.0001.0004 This attribute defines the state settings of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.4 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: amperageProbeStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5 + type: gauge + help: 0600.0030.0001.0005 This attribute defines the probe status of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.5 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCriticalUpper + 5: criticalUpper + 6: nonRecoverableUpper + 7: nonCriticalLower + 8: criticalLower + 9: nonRecoverableLower + 10: failed + - name: amperageProbeReading + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 + type: gauge + help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeType + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.7 + type: gauge + help: 0600.0030.0001.0007 This attribute defines the type of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.7 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: amperageProbeTypeIsOther + 2: amperageProbeTypeIsUnknown + 3: amperageProbeTypeIs1Point5Volt + 4: amperageProbeTypeIs3Point3volt + 5: amperageProbeTypeIs5Volt + 6: amperageProbeTypeIsMinus5Volt + 7: amperageProbeTypeIs12Volt + 8: amperageProbeTypeIsMinus12Volt + 9: amperageProbeTypeIsIO + 10: amperageProbeTypeIsCore + 11: amperageProbeTypeIsFLEA + 12: amperageProbeTypeIsBattery + 13: amperageProbeTypeIsTerminator + 14: amperageProbeTypeIs2Point5Volt + 15: amperageProbeTypeIsGTL + 16: amperageProbeTypeIsDiscrete + 23: amperageProbeTypeIsPowerSupplyAmps + 24: amperageProbeTypeIsPowerSupplyWatts + 25: amperageProbeTypeIsSystemAmps + 26: amperageProbeTypeIsSystemWatts + - name: amperageProbeLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.8 + type: OctetString + help: 0600.0030.0001.0008 This attribute defines the location of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.8 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeUpperNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.9 + type: gauge + help: 0600.0030.0001.0009 This attribute defines the upper nonrecoverable threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.9 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeUpperCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.10 + type: gauge + help: 0600.0030.0001.0010 This attribute defines the upper critical threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.10 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeUpperNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.11 + type: gauge + help: 0600.0030.0001.0011 This attribute defines the upper noncritical threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.11 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeLowerNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.12 + type: gauge + help: 0600.0030.0001.0012 This attribute defines the lower noncritical threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.12 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeLowerCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.13 + type: gauge + help: 0600.0030.0001.0013 This attribute defines the lower critical threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.13 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeLowerNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.14 + type: gauge + help: 0600.0030.0001.0014 This attribute defines the lower nonrecoverable threshold of the amperage probe - 1.3.6.1.4.1.674.10892.5.4.600.30.1.14 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + - name: amperageProbeProbeCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.15 + type: gauge + help: 0600.0030.0001.0015 This attribute defines the probe capabilities of the amperage probe. - 1.3.6.1.4.1.674.10892.5.4.600.30.1.15 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: upperNonCriticalThresholdSetCapable + 2: lowerNonCriticalThresholdSetCapable + 4: upperNonCriticalThresholdDefaultCapable + 8: lowerNonCriticalThresholdDefaultCapable + - name: amperageProbeDiscreteReading + oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.16 + type: gauge + help: 0600.0030.0001.0016 This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.16 + indexes: + - labelname: amperageProbechassisIndex + type: gauge + - labelname: amperageProbeIndex + type: gauge + enum_values: + 1: amperageIsGood + 2: amperageIsBad + - name: systemBatteryChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.1 + type: gauge + help: 0600.0050.0001.0001 This attribute defines the index (one based) of the system chassis that contains the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.1 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + - name: systemBatteryIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.2 + type: gauge + help: 0600.0050.0001.0002 This attribute defines the index (one based) of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.2 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + - name: systemBatteryStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 + type: gauge + help: 0600.0050.0001.0003 This attribute defines the state capabilities of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: systemBatteryStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.4 + type: gauge + help: 0600.0050.0001.0004 This attribute defines the state settings of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.4 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: systemBatteryStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5 + type: gauge + help: 0600.0050.0001.0005 This attribute defines the status of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.5 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemBatteryReading + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6 + type: gauge + help: 0600.0050.0001.0006 This attribute defines the reading of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.6 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + enum_values: + 1: predictiveFailure + 2: failed + 4: presenceDetected + - name: systemBatteryLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.600.50.1.7 + type: OctetString + help: 0600.0050.0001.0007 This attribute defines the location of the battery. - 1.3.6.1.4.1.674.10892.5.4.600.50.1.7 + indexes: + - labelname: systemBatteryChassisIndex + type: gauge + - labelname: systemBatteryIndex + type: gauge + - name: powerUsageChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 + type: gauge + help: 0600.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageIndex + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 + type: gauge + help: 0600.0060.0001.0002 This attribute defines the index (one based) of the power usage information. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.3 + type: gauge + help: 0600.0060.0001.0003 This attribute defines the state capabilities of the power usage information. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.3 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: powerUsageStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.4 + type: gauge + help: 0600.0060.0001.0004 This attribute defines the state settings of the power usage information. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.4 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: powerUsageStatus + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.5 + type: gauge + help: 0600.0060.0001.0005 This attribute defines the status of the power usage information. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.5 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: powerUsageEntityName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.6 + type: OctetString + help: 0600.0060.0001.0006 This attribute defines the name of the entity associated with this power usage information. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.6 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageCumulativeWattage + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.7 + type: gauge + help: 0600.0060.0001.0007 This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.7 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageCumulativeWattageStartDateName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.8 + type: OctetString + help: 0600.0060.0001.0008 This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.8 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakWatts + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.9 + type: gauge + help: 0600.0060.0001.0009 This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.9 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakWattsStartDateName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.10 + type: OctetString + help: 0600.0060.0001.0010 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.10 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakWattsReadingDateName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.11 + type: OctetString + help: 0600.0060.0001.0011 This attribute defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.11 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakAmps + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.12 + type: gauge + help: 0600.0060.0001.0012 This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.12 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakAmpsStartDateName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.13 + type: OctetString + help: 0600.0060.0001.0013 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.13 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakAmpsReadingDateName + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.14 + type: OctetString + help: 0600.0060.0001.0014 This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.14 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageIdlePower + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.15 + type: gauge + help: 0600.0060.0001.0015 This attribute defines the system idle power (in Watts) - 1.3.6.1.4.1.674.10892.5.4.600.60.1.15 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageMaxPotentialPower + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.16 + type: gauge + help: 0600.0060.0001.0016 This attribute defines the system maximum potential power (in Watts) - 1.3.6.1.4.1.674.10892.5.4.600.60.1.16 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePowerCapCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.17 + type: gauge + help: 0600.0060.0001.0017 This attribute defines the system power cap capabilities. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.17 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + enum_values: + 1: enable + 2: disable + - name: powerUsagePowerCapSetting + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.18 + type: gauge + help: 0600.0060.0001.0018 This attribute defines the system power cap setting. - 1.3.6.1.4.1.674.10892.5.4.600.60.1.18 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + enum_values: + 1: enabled + - name: powerUsagePowerCapValue + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.19 + type: gauge + help: 0600.0060.0001.0019 This attribute defines the system power cap value (in Watts). - 1.3.6.1.4.1.674.10892.5.4.600.60.1.19 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsageInstantaneousHeadroom + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.20 + type: gauge + help: 0600.0060.0001.0020 This attribute defines the system instantaneous headroom (in Watts) - 1.3.6.1.4.1.674.10892.5.4.600.60.1.20 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: powerUsagePeakHeadroom + oid: 1.3.6.1.4.1.674.10892.5.4.600.60.1.21 + type: gauge + help: 0600.0060.0001.0021 This attribute defines the system peak headroom (in Watts) - 1.3.6.1.4.1.674.10892.5.4.600.60.1.21 + indexes: + - labelname: powerUsageChassisIndex + type: gauge + - labelname: powerUsageIndex + type: gauge + - name: coolingUnitchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.1 + type: gauge + help: 0700.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.1 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + - name: coolingUnitIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.2 + type: gauge + help: 0700.0010.0001.0002 This attribute defines the index (one based) of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.2 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + - name: coolingUnitStateCapabilties + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.3 + type: gauge + help: 0700.0010.0001.0003 This attribute defines the state capabilities of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.3 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: coolingUnitStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.4 + type: gauge + help: 0700.0010.0001.0004 This attribute defines the state settings of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.4 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: coolingUnitRedundancyStatus + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.5 + type: gauge + help: 0700.0010.0001.0005 This attribute defines the redundancy status of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.5 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: full + 4: degraded + 5: lost + 6: notRedundant + 7: redundancyOffline + - name: coolingDeviceCountForRedundancy + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.6 + type: gauge + help: 0700.0010.0001.0006 This attribute defines the total number of cooling devices required for this cooling unit to have full redundancy. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.6 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + - name: coolingUnitName + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.7 + type: OctetString + help: 0700.0010.0001.0007 This attribute defines the name of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.7 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + - name: coolingUnitStatus + oid: 1.3.6.1.4.1.674.10892.5.4.700.10.1.8 + type: gauge + help: 0700.0010.0001.0008 This attribute defines the status of the cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.10.1.8 + indexes: + - labelname: coolingUnitchassisIndex + type: gauge + - labelname: coolingUnitIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: coolingDevicechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.1 + type: gauge + help: 0700.0012.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.1 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2 + type: gauge + help: 0700.0012.0001.0002 This attribute defines the index (one based) of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.2 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.3 + type: gauge + help: 0700.0012.0001.0003 This attribute defines the state capabilities of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.3 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: coolingDeviceStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.4 + type: gauge + help: 0700.0012.0001.0004 This attribute defines the state settings of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.4 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: coolingDeviceStatus + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 + type: gauge + help: 0700.0012.0001.0005 This attribute defines the probe status of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCriticalUpper + 5: criticalUpper + 6: nonRecoverableUpper + 7: nonCriticalLower + 8: criticalLower + 9: nonRecoverableLower + 10: failed + - name: coolingDeviceReading + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6 + type: gauge + help: 0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.12.1.6 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceType + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 + type: gauge + help: 0700.0012.0001.0007 This attribute defines the type of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: coolingDeviceTypeIsOther + 2: coolingDeviceTypeIsUnknown + 3: coolingDeviceTypeIsAFan + 4: coolingDeviceTypeIsABlower + 5: coolingDeviceTypeIsAChipFan + 6: coolingDeviceTypeIsACabinetFan + 7: coolingDeviceTypeIsAPowerSupplyFan + 8: coolingDeviceTypeIsAHeatPipe + 9: coolingDeviceTypeIsRefrigeration + 10: coolingDeviceTypeIsActiveCooling + 11: coolingDeviceTypeIsPassiveCooling + - name: coolingDeviceLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 + type: OctetString + help: 0700.0012.0001.0008 This attribute defines the location name of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceUpperNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.9 + type: gauge + help: 0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.9 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceUpperCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.10 + type: gauge + help: 0700.0012.0001.0010 This attribute defines the upper critical threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.10 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceUpperNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.11 + type: gauge + help: 0700.0012.0001.0011 This attribute defines the upper noncritical threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.11 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceLowerNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.12 + type: gauge + help: 0700.0012.0001.0012 This attribute defines the lower noncritical threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.12 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceLowerCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.13 + type: gauge + help: 0700.0012.0001.0013 This attribute defines the lower critical threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.13 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceLowerNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.14 + type: gauge + help: 0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold of the cooling device - 1.3.6.1.4.1.674.10892.5.4.700.12.1.14 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDevicecoolingUnitIndexReference + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.15 + type: gauge + help: 0700.0012.0001.0015 This attribute defines the index to the associated cooling unit. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.15 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: coolingDeviceSubType + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.16 + type: gauge + help: 0700.0012.0001.0016 This attribute defines the subtype of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.16 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: coolingDeviceSubTypeIsOther + 2: coolingDeviceSubTypeIsUnknown + 3: coolingDeviceSubTypeIsAFanThatReadsInRPM + 4: coolingDeviceSubTypeIsAFanReadsONorOFF + 5: coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM + 6: coolingDeviceSubTypeIsAPowerSupplyFanThatReadsONorOFF + 16: coolingDeviceSubTypeIsDiscrete + - name: coolingDeviceProbeCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.17 + type: gauge + help: 0700.0012.0001.0017 This attribute defines the probe capabilities of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.17 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: upperNonCriticalThresholdSetCapable + 2: lowerNonCriticalThresholdSetCapable + 4: upperNonCriticalThresholdDefaultCapable + 8: lowerNonCriticalThresholdDefaultCapable + - name: coolingDeviceDiscreteReading + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.18 + type: gauge + help: 0700.0012.0001.0018 This attribute defines the reading for a cooling device of type coolingDeviceSubTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.12.1.18 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + enum_values: + 1: coolingDeviceIsGood + 2: coolingDeviceIsBad + - name: coolingDeviceFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.700.12.1.19 + type: OctetString + help: 0700.0012.0001.0019 Fully qualified device descriptor (FQDD) of the cooling device. - 1.3.6.1.4.1.674.10892.5.4.700.12.1.19 + indexes: + - labelname: coolingDevicechassisIndex + type: gauge + - labelname: coolingDeviceIndex + type: gauge + - name: temperatureProbechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 + type: gauge + help: 0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeIndex + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 + type: gauge + help: 0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 + type: gauge + help: 0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: temperatureProbeStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 + type: gauge + help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: temperatureProbeStatus + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 + type: gauge + help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCriticalUpper + 5: criticalUpper + 6: nonRecoverableUpper + 7: nonCriticalLower + 8: criticalLower + 9: nonRecoverableLower + 10: failed + - name: temperatureProbeReading + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 + type: gauge + help: 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeType + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 + type: gauge + help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: temperatureProbeTypeIsOther + 2: temperatureProbeTypeIsUnknown + 3: temperatureProbeTypeIsAmbientESM + 16: temperatureProbeTypeIsDiscrete + - name: temperatureProbeLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 + type: OctetString + help: 0700.0020.0001.0008 This attribute defines the location name of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeUpperNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 + type: gauge + help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeUpperCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 + type: gauge + help: 0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeUpperNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 + type: gauge + help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeLowerNonCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 + type: gauge + help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeLowerCriticalThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 + type: gauge + help: 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeLowerNonRecoverableThreshold + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 + type: gauge + help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + - name: temperatureProbeProbeCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 + type: gauge + help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: upperNonCriticalThresholdSetCapable + 2: lowerNonCriticalThresholdSetCapable + 4: upperNonCriticalThresholdDefaultCapable + 8: lowerNonCriticalThresholdDefaultCapable + - name: temperatureProbeDiscreteReading + oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 + type: gauge + help: 0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 + indexes: + - labelname: temperatureProbechassisIndex + type: gauge + - labelname: temperatureProbeIndex + type: gauge + enum_values: + 1: temperatureIsGood + 2: temperatureIsBad + - name: processorDevicechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 + type: gauge + help: 1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 + type: gauge + help: 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 + type: gauge + help: 1100.0030.0001.0003 This attribute defines the state capabilities of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: processorDeviceStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 + type: gauge + help: 1100.0030.0001.0004 This attribute defines the state settings of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: processorDeviceStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 + type: gauge + help: 1100.0030.0001.0005 This attribute defines the status of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: processorDeviceType + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 + type: gauge + help: 1100.0030.0001.0007 This attribute defines the type of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: deviceTypeIsOther + 2: deviceTypeIsUnknown + 3: deviceTypeIsCPU + 4: deviceTypeIsMathProcessor + 5: deviceTypeIsDSP + 6: deviceTypeIsAVideoProcessor + - name: processorDeviceManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 + type: OctetString + help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceStatusState + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 + type: gauge + help: 1100.0030.0001.0009 This attribute defines the status state of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: enabled + 4: userDisabled + 5: biosDisabled + 6: idle + - name: processorDeviceFamily + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 + type: gauge + help: 1100.0030.0001.0010 This attribute defines the family of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + enum_values: + 1: deviceFamilyIsOther + 2: deviceFamilyIsUnknown + 3: deviceFamilyIs8086 + 4: deviceFamilyIs80286 + 5: deviceFamilyIsIntel386 + 6: deviceFamilyIsIntel486 + 7: deviceFamilyIs8087 + 8: deviceFamilyIs80287 + 9: deviceFamilyIs80387 + 10: deviceFamilyIs80487 + 11: deviceFamilyIsPentium + 12: deviceFamilyIsPentiumPro + 13: deviceFamilyIsPentiumII + 14: deviceFamilyIsPentiumMMX + 15: deviceFamilyIsCeleron + 16: deviceFamilyIsPentiumIIXeon + 17: deviceFamilyIsPentiumIII + 18: deviceFamilyIsPentiumIIIXeon + 19: deviceFamilyIsPentiumIIISpeedStep + 20: deviceFamilyIsItanium + 21: deviceFamilyIsIntelXeon + 22: deviceFamilyIsPentium4 + 23: deviceFamilyIsIntelXeonMP + 24: deviceFamilyIsIntelItanium2 + 25: deviceFamilyIsK5 + 26: deviceFamilyIsK6 + 27: deviceFamilyIsK6Dash2 + 28: deviceFamilyIsK6Dash3 + 29: deviceFamilyIsAMDAthlon + 30: deviceFamilyIsAMD2900 + 31: deviceFamilyIsK6Dash2Plus + 32: deviceFamilyIsPowerPC + 33: deviceFamilyIsPowerPC601 + 34: deviceFamilyIsPowerPC603 + 35: deviceFamilyIsPowerPC603Plus + 36: deviceFamilyIsPowerPC604 + 37: deviceFamilyIsPowerPC620 + 38: deviceFamilyIsPowerPCx704 + 39: deviceFamilyIsPowerPC750 + 40: deviceFamilyIsIntelCoreDuo + 41: deviceFamilyIsIntelCoreDuoMobile + 42: deviceFamilyIsIntelCoreSoloMobile + 43: deviceFamilyIsIntelAtom + 48: deviceFamilyIsAlpha + 49: deviceFamilyIsAlpha21064 + 50: deviceFamilyIsAlpha21066 + 51: deviceFamilyIsAlpha21164 + 52: deviceFamilyIsAlpha21164PC + 53: deviceFamilyIsAlpha21164a + 54: deviceFamilyIsAlpha21264 + 55: deviceFamilyIsAlpha21364 + 56: deviceFamilyIsAMDTurionIIUltraDualMobileM + 57: deviceFamilyIsAMDTurionIIDualMobileM + 58: deviceFamilyIsAMDAthlonIIDualMobileM + 59: deviceFamilyIsAMDOpteron6100 + 60: deviceFamilyIsAMDOpteron4100 + 61: deviceFamilyIsAMDOpteron6200 + 62: deviceFamilyIsAMDOpteron4200 + 64: deviceFamilyIsMIPS + 65: deviceFamilyIsMIPSR4000 + 66: deviceFamilyIsMIPSR4200 + 67: deviceFamilyIsMIPSR4400 + 68: deviceFamilyIsMIPSR4600 + 69: deviceFamilyIsMIPSR10000 + 80: deviceFamilyIsSPARC + 81: deviceFamilyIsSuperSPARC + 82: deviceFamilyIsmicroSPARCII + 83: deviceFamilyIsmicroSPARCIIep + 84: deviceFamilyIsUltraSPARC + 85: deviceFamilyIsUltraSPARCII + 86: deviceFamilyIsUltraSPARCIIi + 87: deviceFamilyIsUltraSPARCIII + 88: deviceFamilyIsUltraSPARCIIIi + 96: deviceFamilyIs68040 + 97: deviceFamilyIs68xxx + 98: deviceFamilyIs68000 + 99: deviceFamilyIs68010 + 100: deviceFamilyIs68020 + 101: deviceFamilyIs68030 + 107: deviceFamilyIsAMDZen + 112: deviceFamilyIsHobbit + 120: deviceFamilyIsCrusoeTM5000 + 121: deviceFamilyIsCrusoeTM3000 + 122: deviceFamilyIsEfficeonTM8000 + 128: deviceFamilyIsWeitek + 130: deviceFamilyIsIntelCeleronM + 131: deviceFamilyIsAMDAthlon64 + 132: deviceFamilyIsAMDOpteron + 133: deviceFamilyIsAMDSempron + 134: deviceFamilyIsAMDTurion64Mobile + 135: deviceFamilyIsDualCoreAMDOpteron + 136: deviceFamilyIsAMDAthlon64X2DualCore + 137: deviceFamilyIsAMDTurion64X2Mobile + 138: deviceFamilyIsQuadCoreAMDOpteron + 139: deviceFamilyIsThirdGenerationAMDOpteron + 140: deviceFamilyIsAMDPhenomFXQuadCore + 141: deviceFamilyIsAMDPhenomX4QuadCore + 142: deviceFamilyIsAMDPhenomX2DualCore + 143: deviceFamilyIsAMDAthlonX2DualCore + 144: deviceFamilyIsPARISC + 145: deviceFamilyIsPARISC8500 + 146: deviceFamilyIsPARISC8000 + 147: deviceFamilyIsPARISC7300LC + 148: deviceFamilyIsPARISC7200 + 149: deviceFamilyIsPARISC7100LC + 150: deviceFamilyIsPARISC7100 + 160: deviceFamilyIsV30 + 161: deviceFamilyIsQuadCoreIntelXeon3200 + 162: deviceFamilyIsDualCoreIntelXeon3000 + 163: deviceFamilyIsQuadCoreIntelXeon5300 + 164: deviceFamilyIsDualCoreIntelXeon5100 + 165: deviceFamilyIsDualCoreIntelXeon5000 + 166: deviceFamilyIsDualCoreIntelXeonLV + 167: deviceFamilyIsDualCoreIntelXeonULV + 168: deviceFamilyIsDualCoreIntelXeon7100 + 169: deviceFamilyIsQuadCoreIntelXeon5400 + 170: deviceFamilyIsQuadCoreIntelXeon + 171: deviceFamilyIsDualCoreIntelXeon5200 + 172: deviceFamilyIsDualCoreIntelXeon7200 + 173: deviceFamilyIsQuadCoreIntelXeon7300 + 174: deviceFamilyIsQuadCoreIntelXeon7400 + 175: deviceFamilyIsMultiCoreIntelXeon7400 + 176: deviceFamilyIsM1 + 177: deviceFamilyIsM2 + 179: deviceFamilyIsIntelPentium4HT + 180: deviceFamilyIsAS400 + 182: deviceFamilyIsAMDAthlonXP + 183: deviceFamilyIsAMDAthlonMP + 184: deviceFamilyIsAMDDuron + 185: deviceFamilyIsIntelPentiumM + 186: deviceFamilyIsIntelCeleronD + 187: deviceFamilyIsIntelPentiumD + 188: deviceFamilyIsIntelPentiumExtreme + 189: deviceFamilyIsIntelCoreSolo + 190: deviceFamilyIsIntelCore2 + 191: deviceFamilyIsIntelCore2Duo + 192: deviceFamilyIsIntelCore2Solo + 193: deviceFamilyIsIntelCore2Extreme + 194: deviceFamilyIsIntelCore2Quad + 195: deviceFamilyIsIntelCore2ExtremeMobile + 196: deviceFamilyIsIntelCore2DuoMobile + 197: deviceFamilyIsIntelCore2SoloMobile + 198: deviceFamilyIsIntelCorei7 + 199: deviceFamilyIsDualCoreIntelCeleron + 200: deviceFamilyIsIBM390 + 201: deviceFamilyIsG4 + 202: deviceFamilyIsG5 + 203: deviceFamilyIsESA390G6 + 204: deviceFamilyIszArchitectur + 205: deviceFamilyIsIntelCorei5 + 206: deviceFamilyIsIntelCorei3 + 210: deviceFamilyIsVIAC7M + 211: deviceFamilyIsVIAC7D + 212: deviceFamilyIsVIAC7 + 213: deviceFamilyIsVIAEden + 214: deviceFamilyIsMultiCoreIntelXeon + 215: deviceFamilyIsDualCoreIntelXeon3xxx + 216: deviceFamilyIsQuadCoreIntelXeon3xxx + 217: deviceFamilyIsVIANano + 218: deviceFamilyIsDualCoreIntelXeon5xxx + 219: deviceFamilyIsQuadCoreIntelXeon5xxx + 221: deviceFamilyIsDualCoreIntelXeon7xxx + 222: deviceFamilyIsQuadCoreIntelXeon7xxx + 223: deviceFamilyIsMultiCoreIntelXeon7xxx + 224: deviceFamilyIsMultiCoreIntelXeon3400 + 230: deviceFamilyIsEmbeddedAMDOpertonQuadCore + 231: deviceFamilyIsAMDPhenomTripleCore + 232: deviceFamilyIsAMDTurionUltraDualCoreMobile + 233: deviceFamilyIsAMDTurionDualCoreMobile + 234: deviceFamilyIsAMDAthlonDualCore + 235: deviceFamilyIsAMDSempronSI + 236: deviceFamilyIsAMDPhenomII + 237: deviceFamilyIsAMDAthlonII + 238: deviceFamilyIsSixCoreAMDOpteron + 239: deviceFamilyIsAMDSempronM + 250: deviceFamilyIsi860 + 251: deviceFamilyIsi960 + - name: processorDeviceMaximumSpeed + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 + type: gauge + help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceCurrentSpeed + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 + type: gauge + help: 1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceExternalClockSpeed + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 + type: gauge + help: 1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceVoltage + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 + type: gauge + help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceVersionName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 + type: OctetString + help: 1100.0030.0001.0016 This attribute defines the version of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceCoreCount + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 + type: gauge + help: 1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceCoreEnabledCount + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 + type: gauge + help: 1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceThreadCount + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 + type: gauge + help: 1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceCharacteristics + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 + type: gauge + help: 1100.0030.0001.0020 This attribute defines characteristics of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceExtendedCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 + type: gauge + help: 1100.0030.0001.0021 This attribute defines extended capabilities of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceExtendedSettings + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 + type: gauge + help: 1100.0030.0001.0022 This attribute defines extended settings of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceBrandName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 + type: OctetString + help: 1100.0030.0001.0023 This attribute defines the brand of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 + type: OctetString + help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 + indexes: + - labelname: processorDevicechassisIndex + type: gauge + - labelname: processorDeviceIndex + type: gauge + - name: processorDeviceStatusChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.1 + type: gauge + help: 1100.0032.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.1 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + - name: processorDeviceStatusIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.2 + type: gauge + help: 1100.0032.0001.0002 This attribute defines the index (one based) of the processor device status probe. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.2 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + - name: processorDeviceStatusStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.3 + type: gauge + help: 1100.0032.0001.0003 This attribute defines the state capabilities of the processor device status probe. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.3 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: processorDeviceStatusStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.4 + type: gauge + help: 1100.0032.0001.0004 This attribute defines the state settings of the processor device status probe. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.4 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: processorDeviceStatusStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5 + type: gauge + help: 1100.0032.0001.0005 This attribute defines the status of the processor device status probe - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: processorDeviceStatusReading + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.6 + type: gauge + help: 1100.0032.0001.0006 This attribute defines the reading of the processor device status probe. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.6 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + enum_values: + 1: internalError + 2: thermalTrip + 32: configurationError + 128: processorPresent + 256: processorDisabled + 512: terminatorPresent + 1024: processorThrottled + - name: processorDeviceStatusLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.7 + type: OctetString + help: 1100.0032.0001.0007 This attribute defines the location name of the processor device status probe. - 1.3.6.1.4.1.674.10892.5.4.1100.32.1.7 + indexes: + - labelname: processorDeviceStatusChassisIndex + type: gauge + - labelname: processorDeviceStatusIndex + type: gauge + - name: memoryDevicechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.1 + type: gauge + help: 1100.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.1 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.2 + type: gauge + help: 1100.0050.0001.0002 This attribute defines the index (one based) of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.2 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.3 + type: gauge + help: 1100.0050.0001.0003 This attribute defines the state capabilities of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.3 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: memoryDeviceStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.4 + type: gauge + help: 1100.0050.0001.0004 This attribute defines the state settings of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.4 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: memoryDeviceStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5 + type: gauge + help: 1100.0050.0001.0005 This attribute defines the status of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: memoryDeviceType + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 + type: gauge + help: 1100.0050.0001.0007 This attribute defines the type of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 1: deviceTypeIsOther + 2: deviceTypeIsUnknown + 3: deviceTypeIsDRAM + 4: deviceTypeIsEDRAM + 5: deviceTypeIsVRAM + 6: deviceTypeIsSRAM + 7: deviceTypeIsRAM + 8: deviceTypeIsROM + 9: deviceTypeIsFLASH + 10: deviceTypeIsEEPROM + 11: deviceTypeIsFEPROM + 12: deviceTypeIsEPROM + 13: deviceTypeIsCDRAM + 14: deviceTypeIs3DRAM + 15: deviceTypeIsSDRAM + 16: deviceTypeIsSGRAM + 17: deviceTypeIsRDRAM + 18: deviceTypeIsDDR + 19: deviceTypeIsDDR2 + 20: deviceTypeIsDDR2FBDIMM + 24: deviceTypeIsDDR3 + 25: deviceTypeIsFBD2 + 26: deviceTypeIsDDR4 + - name: memoryDeviceLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8 + type: OctetString + help: 1100.0050.0001.0008 This attribute defines the location of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceBankLocationName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.10 + type: OctetString + help: 1100.0050.0001.0010 This attribute defines the location of the bank for the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.10 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceSize + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 + type: gauge + help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceSpeed + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.15 + type: gauge + help: 1100.0050.0001.0015 This attribute defines the maximum capable speed in megahertz (MHz) of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.15 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.21 + type: OctetString + help: 1100.0050.0001.0021 This attribute defines the manufacturer of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.21 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDevicePartNumberName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.22 + type: OctetString + help: 1100.0050.0001.0022 This attribute defines the manufacturer's part number for the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.22 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceSerialNumberName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.23 + type: OctetString + help: 1100.0050.0001.0023 This attribute defines the serial number of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.23 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.26 + type: OctetString + help: 1100.0050.0001.0026 Fully qualified device descriptor (FQDD) of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.26 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceCurrentOperatingSpeed + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.27 + type: gauge + help: 1100.0050.0001.0027 This attribute defines the current operating speed in megahertz (MHz) of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.27 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceTechnology + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.28 + type: gauge + help: 1100.0050.0001.0028 This attribute defines the type or technology of the memory device. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.28 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: dram + 4: nvdimmn + 5: nvdimmf + 6: nvdimmp + 7: intelpersistentmemory + - name: memoryDeviceVolatileSize + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.29 + type: gauge + help: 1100.0050.0001.0029 This attribute defines the volatile size of the memory device in MBs. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.29 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceNonVolatilesSize + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.30 + type: gauge + help: 1100.0050.0001.0030 This attribute defines the Non Volatile size of the memory device in MBs. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.30 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceCacheSize + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.31 + type: gauge + help: 1100.0050.0001.0031 This attribute defines the Cache size of the memory device in MBs. - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.31 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + - name: memoryDeviceRemainingRatedWriteEndurance + oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.32 + type: gauge + help: 1100.0050.0001.0032 This attribute defines the percent of remaining life for the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.32 + indexes: + - labelname: memoryDevicechassisIndex + type: gauge + - labelname: memoryDeviceIndex + type: gauge + enum_values: + 255: notApplicable + - name: pCIDevicechassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.1 + type: gauge + help: 1100.0080.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.1 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: pCIDeviceIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.2 + type: gauge + help: 1100.0080.0001.0002 This attribute defines the index (one based) of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.2 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: pCIDeviceStateCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.3 + type: gauge + help: 1100.0080.0001.0003 This attribute defines the state capabilities of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.3 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + enum_values: + 1: unknownCapabilities + 2: enableCapable + 4: notReadyCapable + 6: enableAndNotReadyCapable + - name: pCIDeviceStateSettings + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.4 + type: gauge + help: 1100.0080.0001.0004 This attribute defines the state settings of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.4 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 4: notReady + 6: enabledAndNotReady + - name: pCIDeviceStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.5 + type: gauge + help: 1100.0080.0001.0005 This attribute defines the status of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.5 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: pCIDeviceDataBusWidth + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.7 + type: gauge + help: 1100.0080.0001.0007 This attribute defines the width of the data bus of the PCI device - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.7 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: pCIDeviceManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.8 + type: OctetString + help: 1100.0080.0001.0008 This attribute defines the name of the manufacturer of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.8 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: pCIDeviceDescriptionName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.9 + type: OctetString + help: 1100.0080.0001.0009 This attribute defines the description of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.9 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: pCIDeviceFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.12 + type: OctetString + help: 1100.0080.0001.0012 Fully qualified device descriptor (FQDD) of the PCI device. - 1.3.6.1.4.1.674.10892.5.4.1100.80.1.12 + indexes: + - labelname: pCIDevicechassisIndex + type: gauge + - labelname: pCIDeviceIndex + type: gauge + - name: networkDeviceChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.1 + type: gauge + help: 1100.0090.0001.0001 This attribute defines the index (one based) of the system chassis that contains the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.1 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.2 + type: gauge + help: 1100.0090.0001.0002 This attribute defines the index (one based) of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.2 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3 + type: gauge + help: 1100.0090.0001.0003 This attribute defines the status of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: networkDeviceConnectionStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.4 + type: gauge + help: 1100.0090.0001.0004 This attribute defines the connection status of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.4 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + enum_values: + 1: connected + 2: disconnected + 3: driverBad + 4: driverDisabled + 10: hardwareInitalizing + 11: hardwareResetting + 12: hardwareClosing + 13: hardwareNotReady + - name: networkDeviceProductName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.6 + type: OctetString + help: 1100.0090.0001.0006 This attribute defines the product name of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.6 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceVendorName + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.7 + type: OctetString + help: 1100.0090.0001.0007 This attribute defines the name of the vendor of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.7 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceCurrentMACAddress + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15 + type: OctetString + help: 1100.0090.0001.0015 This attribute defines the current MAC address of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDevicePermanentMACAddress + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.16 + type: OctetString + help: 1100.0090.0001.0016 This attribute defines the permanent MAC address of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.16 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDevicePCIBusNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.17 + type: gauge + help: 1100.0090.0001.0017 This attribute defines the PCI bus number of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.17 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDevicePCIDeviceNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.18 + type: gauge + help: 1100.0090.0001.0018 This attribute defines the PCI device number of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.18 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDevicePCIFunctionNumber + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.19 + type: gauge + help: 1100.0090.0001.0019 This attribute defines the PCI function number of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.19 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceTOECapabilityFlags + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.23 + type: gauge + help: 1100.0090.0001.0023 This attribute defines the TCP/IP Offload Engine (TOE) capability flags of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.23 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: available + 4: notAvailable + 8: cannotBeDetermined + 16: driverNotResponding + - name: networkDeviceiSCSICapabilityFlags + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.27 + type: gauge + help: 1100.0090.0001.0027 This attribute defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.27 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + enum_values: + 1: unknown + 2: available + 4: notAvailable + 8: cannotBeDetermined + 16: driverNotResponding + - name: networkDeviceiSCSIEnabled + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.28 + type: gauge + help: 1100.0090.0001.0028 This attribute defines if iSCSI is enabled for the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.28 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: networkDeviceCapabilities + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.29 + type: gauge + help: 1100.0090.0001.0029 This attribute defines the capabilities of the network device - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.29 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + enum_values: + 1: supported + 2: toe + 4: iscsiOffload + 8: fcoeOffload + - name: networkDeviceFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 + type: OctetString + help: 1100.0090.0001.0030 Fully qualified device descriptor (FQDD) of the network device. - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 + indexes: + - labelname: networkDeviceChassisIndex + type: gauge + - labelname: networkDeviceIndex + type: gauge + - name: systemSlotchassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.1 + type: gauge + help: 1200.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.1 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + - name: systemSlotIndex + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.2 + type: gauge + help: 1200.0010.0001.0002 This attribute defines the index (one based) of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.2 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + - name: systemSlotStateCapabilitiesUnique + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.3 + type: gauge + help: 1200.0010.0001.0003 This attribute defines the state capabilities of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.3 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: systemSlotHotPlugIsUnknown + 2: systemSlotHotPlugIsHotPluggableCapable + 4: systemSlotHotPlugCanBePoweredOn + 8: systemSlotHotPlugCanSignalAttention + 16: systemSlotHotPlugCanSignalPowerFault + 32: systemSlotHotPlugCanSignalAdapterPresent + 64: systemSlotHotPlugCanSignalPowerButtonPressed + 126: canSupportAllHotPlugCapabilities + 128: systemSlotCanProvide5Volts + 256: systemSlotCanProvide3Point3Volts + 512: systemSlotCanSignalIfShared + 1024: systemSlotCanSupportCard16 + 2048: systemSlotCanSupportCardBus + 4096: systemSlotCanSupportZoomVideo + 8192: systemSlotCanSupportModemRingResume + 16384: systemSlotCanSupportPMESignal + 32640: canSupportAllSlotCapabilities + 32766: canSupportAllSlotAndAllHotPlugCapabilities + - name: systemSlotStateSettingsUnique + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.4 + type: gauge + help: 1200.0010.0001.0004 This attribute defines the state settings of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.4 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: systemSlotHotPlugIsUnknown + 2: systemSlotHotPlugIsHotPluggable + 4: systemSlotHotPlugIsPoweredOn + 8: systemSlotHotPlugIsAtAttention + 16: systemSlotHotPlugHasPowerFaulted + 32: systemSlotHotPlugAdapterIsPresent + 36: systemSlotHotPlugAdapterPresentAndPoweredOn + 64: systemSlotHotPlugPowerButtonPressed + 128: systemSlotProvides5Volts + 256: systemSlotProvides3Point3Volts + 512: systemSlotIsShared + 1024: systemSlotSupportsCard16 + 2048: systemSlotSupportsCardBus + 4096: systemSlotSupportsZoomVideo + 8192: systemSlotSupportsModemRingResume + 16384: systemSlotSupportsPMESignal + 16770: supportsPMEand3P3Vand5VandHotPluggable + 16804: supportsPMEand3P3Vand5VhasAdapterOn + 16806: supportsPMEand3P3Vand5VhasAdapterOnandisHotPluggable + 17316: supportsPMEand3P3VIsSharedand5VhasAdapterOnandHotPlugable + - name: systemSlotStatus + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.5 + type: gauge + help: 1200.0010.0001.0005 This attribute defines the status of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.5 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: systemSlotCurrentUsage + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.6 + type: gauge + help: 1200.0010.0001.0006 This attribute defines the current usage of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.6 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: systemSlotUsageIsOther + 2: systemSlotUsageIsUnknown + 3: systemSlotUsageIsAvailable + 4: systemSlotUsageIsInUse + - name: systemSlotType + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.7 + type: gauge + help: 1200.0010.0001.0007 This attribute defines the type of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.7 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: systemSlotIsOther + 2: systemSlotIsUnknown + 3: systemSlotIsISA + 4: systemSlotIsMCA + 5: systemSlotIsEISA + 6: systemSlotIsPCI + 7: systemSlotIsPCMCIA + 8: systemSlotIsVLVESA + 9: systemSlotIsProprietary + 10: systemSlotIsProcessorCard + 11: systemSlotIsProprietaryMemory + 12: systemSlotIsIORiserCard + 13: systemSlotIsNuBUS + 14: systemSlotIsPCI66MHz + 15: systemSlotIsAGP + 16: systemSlotIsAGP2X + 17: systemSlotIsAGP4X + 18: systemSlotIsPC98C20 + 19: systemSlotIsPC98C24 + 20: systemSlotIsPC98E + 21: systemSlotIsPC98LocalBus + 22: systemSlotIsPC98Card + 23: systemSlotIsPCIX + 24: systemSlotIsPCIExpress + 25: systemSlotIsAGP8X + 166: systemSlotIsPCIExpressX1 + 167: systemSlotIsPCIExpressX2 + 168: systemSlotIsPCIExpressX4 + 169: systemSlotIsPCIExpressX8 + 170: systemSlotIsPCIExpressX16 + 171: systemSlotIsPCIExpressGen2 + 172: systemSlotIsPCIExpressGen2X1 + 173: systemSlotIsPCIExpressGen2X2 + 174: systemSlotIsPCIExpressGen2X4 + 175: systemSlotIsPCIExpressGen2X8 + 176: systemSlotIsPCIExpressGen2X16 + - name: systemSlotSlotExternalSlotName + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.8 + type: OctetString + help: 1200.0010.0001.0008 This attribute defines the name of the external connector name of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.8 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + - name: systemSlotCategory + oid: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.11 + type: gauge + help: 1200.0010.0001.0011 This attribute defines the category of the system slot. - 1.3.6.1.4.1.674.10892.5.4.1200.10.1.11 + indexes: + - labelname: systemSlotchassisIndex + type: gauge + - labelname: systemSlotIndex + type: gauge + enum_values: + 1: systemSlotCategoryIsOther + 2: systemSlotCategoryIsUnknown + 3: systemSlotCategoryIsBusConnector + 4: systemSlotCategoryIsPCMCIA + 5: systemSlotCategoryIsMotherboard + - name: fruChassisIndex + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.1 + type: gauge + help: 2000.0010.0001.0001 This attribute defines the index (one based) of the system chassis containing the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.1 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruIndex + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 + type: gauge + help: 2000.0010.0001.0002 This attribute defines the index (one based) of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruInformationStatus + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 + type: gauge + help: 2000.0010.0001.0003 This attribute defines the status of the field replaceable unit information. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: fruManufacturerName + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.6 + type: OctetString + help: 2000.0010.0001.0006 This attribute defines the manufacturer of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.6 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruSerialNumberName + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.7 + type: OctetString + help: 2000.0010.0001.0007 This attribute defines the serial number of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.7 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruPartNumberName + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.8 + type: OctetString + help: 2000.0010.0001.0008 This attribute defines the part number of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.8 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruRevisionName + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.9 + type: OctetString + help: 2000.0010.0001.0009 This attribute defines the revision of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.9 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: fruFQDD + oid: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.12 + type: OctetString + help: 2000.0010.0001.0012 Fully qualified device descriptor (FQDD) of the field replaceable unit. - 1.3.6.1.4.1.674.10892.5.4.2000.10.1.12 + indexes: + - labelname: fruChassisIndex + type: gauge + - labelname: fruIndex + type: gauge + - name: controllerNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 + type: gauge + help: Instance number of this controller entry. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2 + type: DisplayString + help: The controller's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerRebuildRate + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 + type: gauge + help: The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerFWVersion + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 + type: DisplayString + help: The controller's current firmware version. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerCacheSizeInMB + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9 + type: gauge + help: The controller's current amount of cache memory in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerRollUpStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 + type: gauge + help: Severity of the controller state - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: controllerComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 + type: gauge + help: The status of the controller itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: controllerDriverVersion + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 + type: DisplayString + help: Currently installed driver version for this controller on the host. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerPCISlot + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 + type: DisplayString + help: The PCI slot on the server where the controller is seated - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerReconstructRate + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48 + type: gauge + help: The reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID level of a virtual disk residing on the disk group. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerPatrolReadRate + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49 + type: gauge + help: The patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerBGIRate + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50 + type: gauge + help: The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerCheckConsistencyRate + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.51 + type: gauge + help: The check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.51 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerPatrolReadMode + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52 + type: gauge + help: Identifies the patrol read mode setting for the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: notSupported + 3: disabled + 4: auto + 5: manual + - name: controllerPatrolReadState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53 + type: gauge + help: This property displays the current state of the patrol read process - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: stopped + 3: active + - name: controllerPersistentHotSpare + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59 + type: gauge + help: Indicates whether hot spare drives would be restored on insertion into the same slot. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerSpinDownUnconfiguredDrives + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 + type: gauge + help: Indicates whether un-configured drives would be put in power save mode by the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerSpinDownHotSpareDrives + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61 + type: gauge + help: Indicates whether hot spare drives would be put in power save mode by the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerSpinDownTimeInterval + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62 + type: gauge + help: The duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerPreservedCache + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69 + type: gauge + help: Indicates whether preserved cache or pinned cache is present on the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerCheckConsistencyMode + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70 + type: gauge + help: The current check consistency mode setting for the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: unsupported + 3: normal + 4: stopOnError + - name: controllerCopyBackMode + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 + type: gauge + help: The current copy back mode setting for the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: unsupported + 3: "on" + 4: onWithSmart + 5: "off" + - name: controllerSecurityStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72 + type: gauge + help: The controller's current security/encryption status. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: unknown + 2: none + 3: lkm + - name: controllerEncryptionKeyPresent + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.73 + type: gauge + help: Indicates whether encryption key is assigned for the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.73 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerEncryptionCapability + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74 + type: gauge + help: The type of encryption supported by the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: none + 3: lkm + - name: controllerLoadBalanceSetting + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75 + type: gauge + help: The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: unsupported + 3: auto + 4: none + - name: controllerMaxCapSpeed + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 + type: gauge + help: The maximum speed of the controller.in Gigbits per second (Gbps) - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: unknown + 2: oneDotFiveGbps + 3: threeGbps + 4: sixGbps + 5: twelveGbps + - name: controllerSASAddress + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.77 + type: DisplayString + help: The SAS address of the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.77 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78 + type: OctetString + help: The controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 + type: DisplayString + help: The controller's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerT10PICapability + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 + type: gauge + help: Indicates whether the controller supports the T10 PI (Protection Information) - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: capable + 3: notCapable + - name: controllerRAID10UnevenSpansSupported + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81 + type: gauge + help: Indicates whether uneven spans for RAID 10 virtual disk is supported on the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerEnhancedAutoImportForeignConfigMode + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82 + type: gauge + help: Indicates the status of enhanced auto-import of foreign configuration property of the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: other + 2: notSupported + 3: disabled + 4: enabled + - name: controllerBootModeSupported + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83 + type: gauge + help: Indicates whether headless boot mode settings are supported on the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83 + indexes: + - labelname: controllerNumber + type: gauge + - name: controllerBootMode + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84 + type: gauge + help: Indicates the boot mode of the controller - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84 + indexes: + - labelname: controllerNumber + type: gauge + enum_values: + 1: notApplicable + 2: user + 3: contOnError + 4: headlessContOnError + 5: headlessSafe + - name: enclosureNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.1 + type: gauge + help: Instance number of this enclossre/backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.1 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 + type: DisplayString + help: The enclosure/backplane's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 + type: gauge + help: The current state of this enclosure/backplane - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 + indexes: + - labelname: enclosureNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: missing + 5: degraded + - name: enclosureServiceTag + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8 + type: DisplayString + help: Enclosure identification used when consulting customer support. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureAssetTag + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 + type: DisplayString + help: The asset tag information for the enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureConnectedPort + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19 + type: DisplayString + help: The port on the controller to which the storage enclosure is connected. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureRollUpStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 + type: gauge + help: Severity of the enclosure/backplane state - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 + indexes: + - labelname: enclosureNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosureComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.24 + type: gauge + help: The status of the enclosure/backplane.itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.24 + indexes: + - labelname: enclosureNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosureFirmwareVersion + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.26 + type: DisplayString + help: The firmware information for the enclosure/backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.26 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureSASAddress + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30 + type: DisplayString + help: The SAS address of the enclosure/backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureDriveCount + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 + type: gauge + help: The number of disks present in the enclosure/backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureTotalSlots + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32 + type: gauge + help: The total physical drive slots in a storage enclosure or server backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureFanCount + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40 + type: DisplayString + help: The number of fans present in the storage enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosurePSUCount + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 + type: DisplayString + help: The number of Power Supply Units (PSU) present in the storage enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureEMMCount + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 + type: DisplayString + help: The number of Enclosure Management Modules (EMM) present in the storage enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureTempProbeCount + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43 + type: DisplayString + help: The number of temperature sensing devices present in the storage enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureRedundantPath + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44 + type: DisplayString + help: Indicates whether the controller has multiply paths to reach the storage enclosure. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosurePosition + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45 + type: DisplayString + help: The possition of the storage enclosure within a daisy chain. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureBackplaneBayID + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46 + type: DisplayString + help: The unique bay ID of the backplane. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47 + type: OctetString + help: The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 + type: DisplayString + help: The enclosure/backplane's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 + indexes: + - labelname: enclosureNumber + type: gauge + - name: enclosureType + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49 + type: gauge + help: The protocol supported by the backplane - 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49 + indexes: + - labelname: enclosureNumber + type: gauge + enum_values: + 1: other + 2: notApplicable + 3: sassata + 4: pcie + 5: universal + - name: physicalDiskNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 + type: gauge + help: Instance number of this physical disk entry. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 + type: DisplayString + help: The physical disk's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskManufacturer + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 + type: DisplayString + help: The name of the physical disk's manufacturer. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 + type: gauge + help: The current state of this physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: online + 4: foreign + 5: offline + 6: blocked + 7: failed + 8: nonraid + 9: removed + 10: readonly + - name: physicalDiskProductID + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 + type: DisplayString + help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskSerialNo + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 + type: DisplayString + help: The physical disk's unique identification number from the manufacturer. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskRevision + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 + type: DisplayString + help: The firmware version of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskCapacityInMB + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 + type: gauge + help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskUsedSpaceInMB + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 + type: gauge + help: The amount of used space in megabytes on the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskFreeSpaceInMB + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19 + type: gauge + help: The amount of free space in megabytes on the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskBusType + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21 + type: gauge + help: The bus type of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: scsi + 3: sas + 4: sata + 5: fibre + 6: pcie + 7: nvme + - name: physicalDiskSpareState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 + type: gauge + help: The status of the disk as a spare - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: notASpare + 2: dedicatedHotSpare + 3: globalHotSpare + - name: physicalDiskComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 + type: gauge + help: The status of the physical disk itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: physicalDiskPartNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27 + type: DisplayString + help: The part number of the disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskSASAddress + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 + type: DisplayString + help: The SAS address of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskNegotiatedSpeed + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29 + type: gauge + help: The data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps) - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: oneDotFiveGbps + 3: threeGbps + 4: sixGbps + 5: twelveGbps + 6: fiveGTps + 7: eightGTps + 8: sixteenGTps + 9: thirtytwoGTps + - name: physicalDiskCapableSpeed + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.30 + type: gauge + help: The maximum data transfer speed supported by the disk in Gigbits per second (Gbps) - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.30 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: oneDotFiveGbps + 3: threeGbps + 4: sixGbps + 5: twelveGbps + 6: fiveGTps + 7: eightGTps + 8: sixteenGTps + 9: thirtytwoGTps + - name: physicalDiskSmartAlertIndication + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 + type: gauge + help: Indicates whether the physical disk has received a predictive failure alert. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskManufactureDay + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 + type: DisplayString + help: The day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskManufactureWeek + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33 + type: DisplayString + help: The week (1 thru 53) in which the physical disk was manufactured. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskManufactureYear + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34 + type: DisplayString + help: The four digit year in which the physical disk was manufactured. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskMediaType + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35 + type: gauge + help: The media type of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: hdd + 3: ssd + - name: physicalDiskPowerState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42 + type: gauge + help: The power state of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: other + 2: spunUp + 3: spunDown + 4: transition + 5: "on" + - name: physicalDiskRemainingRatedWriteEndurance + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 + type: gauge + help: This property is applicable to SSD media type only - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskOperationalState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.50 + type: gauge + help: The state of the physical disk when there are progressive operations ongoing - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.50 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: notApplicable + 2: rebuild + 3: clear + 4: copyback + - name: physicalDiskProgress + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.51 + type: gauge + help: The progress percentage of the operation that is being performed on the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.51 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskSecurityStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 + type: gauge + help: The security/encryption status of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: supported + 2: notSupported + 3: secured + 4: locked + 5: foreign + - name: physicalDiskFormFactor + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 + type: gauge + help: The form factor of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: unknown + 2: oneDotEight + 3: twoDotFive + 4: threeDotFive + 5: edsffe1DotL + - name: physicalDiskFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 + type: OctetString + help: The physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 + type: DisplayString + help: The physical disk's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskT10PICapability + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.57 + type: gauge + help: Indicates whether the physical disk supports the T10 PI (Protection Information) - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.57 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: other + 2: capable + 3: notCapable + - name: physicalDiskBlockSizeInBytes + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58 + type: gauge + help: The block size (in bytes) of the physical disk - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskProtocolVersion + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 + type: DisplayString + help: Applicable for NVMe devices only - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 + indexes: + - labelname: physicalDiskNumber + type: gauge + - name: physicalDiskPCIeNegotiatedLinkWidth + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.60 + type: gauge + help: Applicable for NVMe devices only - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.60 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: other + 2: notApplicable + 3: byOne + 4: byTwp + 5: byFour + 6: byEight + 7: bySixteen + 8: byThirtyTwp + - name: physicalDiskPCIeCapableLinkWidth + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.61 + type: gauge + help: Applicable for NVMe devices only - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.61 + indexes: + - labelname: physicalDiskNumber + type: gauge + enum_values: + 1: other + 2: notApplicable + 3: byOne + 4: byTwp + 5: byFour + 6: byEight + 7: bySixteen + 8: byThirtyTwp + - name: enclosureFanNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.1 + type: gauge + help: Instance number of this fan. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.1 + indexes: + - labelname: enclosureFanNumber + type: gauge + - name: enclosureFanName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2 + type: DisplayString + help: The fan's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2 + indexes: + - labelname: enclosureFanNumber + type: gauge + - name: enclosureFanState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4 + type: gauge + help: The current state of this fan - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4 + indexes: + - labelname: enclosureFanNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: missing + 5: degraded + - name: enclosureFanSpeed + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 + type: gauge + help: Indicates the current relative speed of the fan. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 + indexes: + - labelname: enclosureFanNumber + type: gauge + - name: enclosureFanComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 + type: gauge + help: The status of the fan itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 + indexes: + - labelname: enclosureFanNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosureFanFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20 + type: OctetString + help: The fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20 + indexes: + - labelname: enclosureFanNumber + type: gauge + - name: enclosureFanDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21 + type: DisplayString + help: The fan's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21 + indexes: + - labelname: enclosureFanNumber + type: gauge + - name: enclosurePowerSupplyNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 + type: gauge + help: Instance number of this power supply unit. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + - name: enclosurePowerSupplyName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 + type: DisplayString + help: The power supply unit's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + - name: enclosurePowerSupplyState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 + type: gauge + help: The current state of this power supply unit - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: missing + 5: degraded + - name: enclosurePowerSupplyPartNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7 + type: DisplayString + help: The part number of the power supply unit. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + - name: enclosurePowerSupplyComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9 + type: gauge + help: The status of the power supply unit itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosurePowerSupplyFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 + type: OctetString + help: The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + - name: enclosurePowerSupplyDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16 + type: DisplayString + help: The power supply unit's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16 + indexes: + - labelname: enclosurePowerSupplyNumber + type: gauge + - name: enclosureTemperatureProbeNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1 + type: gauge + help: Instance number of this temperature probe. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2 + type: DisplayString + help: The temperature probe's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 + type: gauge + help: The current state of this temperature probe - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: missing + 5: degraded + - name: enclosureTemperatureProbeMinWarningValue + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7 + type: gauge + help: The minimum temperature that will force the probe into a warning state. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeMinCriticalValue + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 + type: gauge + help: The minimum temperature that will force the probe into a error state. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeMaxWarningValue + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9 + type: gauge + help: The maximum temperature that will force the probe into a warning state. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeMaxCriticalValue + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 + type: gauge + help: The maximum temperature that will force the probe into a warning state. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeCurValue + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11 + type: gauge + help: The maximum temperature that will force the probe into a warning state. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.13 + type: gauge + help: The status of the enclosure management module.itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.13 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosureTemperatureProbeFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 + type: OctetString + help: The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureTemperatureProbeDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.16 + type: DisplayString + help: The temperature probe's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.16 + indexes: + - labelname: enclosureTemperatureProbeNumber + type: gauge + - name: enclosureManagementModuleNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 + type: gauge + help: Instance number of this enclosure management module. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: enclosureManagementModuleName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2 + type: DisplayString + help: The enclosure management module's name as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: enclosureManagementModuleState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 + type: gauge + help: The current state of this enclosure management module - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: missing + 5: degraded + - name: enclosureManagementModulePartNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 + type: DisplayString + help: The part number of the enclosure management module. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: enclosureManagementModuleFWVersion + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8 + type: DisplayString + help: Firmware version of the enclosure management module. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: enclosureManagementModuleComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 + type: gauge + help: The status of the enclosure management module.itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: enclosureManagementModuleFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.15 + type: OctetString + help: The enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.15 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: enclosureManagementModuleDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 + type: DisplayString + help: The enclosure management module's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 + indexes: + - labelname: enclosureManagementModuleNumber + type: gauge + - name: batteryNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 + type: gauge + help: Instance number of this battery entry. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 + indexes: + - labelname: batteryNumber + type: gauge + - name: batteryState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 + type: gauge + help: Current state of battery - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 + indexes: + - labelname: batteryNumber + type: gauge + enum_values: + 1: unknown + 2: ready + 3: failed + 4: degraded + 5: missing + 6: charging + 7: belowThreshold + - name: batteryComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.6 + type: gauge + help: The status of the battery itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.6 + indexes: + - labelname: batteryNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: batteryPredictedCapacity + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 + type: gauge + help: This entry is obsolete - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 + indexes: + - labelname: batteryNumber + type: gauge + enum_values: + 1: unknown + 2: failed + 3: ready + - name: batteryFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 + type: DisplayString + help: The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 + indexes: + - labelname: batteryNumber + type: gauge + - name: batteryDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 + type: DisplayString + help: The battery's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 + indexes: + - labelname: batteryNumber + type: gauge + - name: virtualDiskNumber + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 + type: gauge + help: Instance number of this virtual disk entry. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 + type: DisplayString + help: The virtual disk's label as entered by the user. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4 + type: gauge + help: 'The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4' + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: unknown + 2: online + 3: failed + 4: degraded + - name: virtualDiskSizeInMB + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6 + type: gauge + help: The size of the virtual disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskWritePolicy + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10 + type: gauge + help: The write policy used by the controller for write operations on this virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: writeThrough + 2: writeBack + 3: writeBackForce + - name: virtualDiskReadPolicy + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11 + type: gauge + help: The read policy used by the controller for read operations on this virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: noReadAhead + 2: readAhead + 3: adaptiveReadAhead + - name: virtualDiskLayout + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13 + type: gauge + help: The virtual disk's RAID type - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: other + 2: r0 + 3: r1 + 4: r5 + 5: r6 + 6: r10 + 7: r50 + 8: r60 + 9: concatRaid1 + 10: concatRaid5 + - name: virtualDiskStripeSize + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14 + type: gauge + help: The stripe size of this virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: other + 2: default + 3: fiveHundredAndTwelvebytes + 4: oneKilobytes + 5: twoKilobytes + 6: fourKilobytes + 7: eightKilobytes + 8: sixteenKilobytes + 9: thirtyTwoKilobytes + 10: sixtyFourKilobytes + 11: oneTwentyEightKilobytes + 12: twoFiftySixKilobytes + 13: fiveOneTwoKilobytes + 14: oneMegabye + 15: twoMegabytes + 16: fourMegabytes + 17: eightMegabytes + 18: sixteenMegabytes + - name: virtualDiskComponentStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 + type: gauge + help: The status of the virtual disk itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: other + 2: unknown + 3: ok + 4: nonCritical + 5: critical + 6: nonRecoverable + - name: virtualDiskBadBlocksDetected + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23 + type: gauge + help: Indicates whether the virtual disk has bad blocks. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskSecured + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.24 + type: gauge + help: Indicates whether the virtual disk is secured or not. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.24 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskIsCacheCade + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 + type: gauge + help: Indicates whether the virtual disk is being used as a secondary cache by the controller. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskDiskCachePolicy + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26 + type: gauge + help: 'The cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26' + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: enabled + 2: disabled + 3: defullt + - name: virtualDiskOperationalState + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 + type: gauge + help: The state of the virtual disk when there are progressive operations ongoing - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: notApplicable + 2: reconstructing + 3: resynching + 4: initializing + 5: backgroundInit + - name: virtualDiskProgress + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.31 + type: gauge + help: The progress percentage of the operation that is being performed on the virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.31 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskAvailableProtocols + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32 + type: DisplayString + help: List of protocols support by physical disks part of this virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskMediaType + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33 + type: DisplayString + help: List of media types of the physical disks part of this virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskRemainingRedundancy + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34 + type: gauge + help: The number of physical disks which can be lost before the virtual disk loses its redundancy. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskFQDD + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 + type: OctetString + help: The virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskDisplayName + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36 + type: DisplayString + help: The virtual disk's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36 + indexes: + - labelname: virtualDiskNumber + type: gauge + - name: virtualDiskT10PIStatus + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37 + type: gauge + help: Indicates whether the virtual disk supports the T10 PI (Protection Information) - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37 + indexes: + - labelname: virtualDiskNumber + type: gauge + enum_values: + 1: other + 2: enabled + 3: disabled + - name: virtualDiskBlockSizeInBytes + oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.38 + type: gauge + help: The block size (in bytes) of the physical disk part of the virtual disk - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.38 + indexes: + - labelname: virtualDiskNumber + type: gauge + dell_rac: + walk: + - 1.3.6.1.4.1.674.10892.2.4.1 + - 1.3.6.1.4.1.674.10892.2.4.2 + metrics: + - name: drsChassisIndex + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.1 + type: gauge + help: 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. - 1.3.6.1.4.1.674.10892.2.4.1.1.1 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + - name: drsPotentialPower + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.2 + type: DisplayString + help: 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers. - 1.3.6.1.4.1.674.10892.2.4.1.1.2 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsIdlePower + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.3 + type: DisplayString + help: 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. - 1.3.6.1.4.1.674.10892.2.4.1.1.3 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsMaxPowerSpecification + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.4 + type: DisplayString + help: 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. - 1.3.6.1.4.1.674.10892.2.4.1.1.4 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsPowerSurplus + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.5 + type: DisplayString + help: 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. - 1.3.6.1.4.1.674.10892.2.4.1.1.5 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsKWhCumulative + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.6 + type: DisplayString + help: 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. - 1.3.6.1.4.1.674.10892.2.4.1.1.6 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsKWhCumulativeTime + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.7 + type: DisplayString + help: 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. - 1.3.6.1.4.1.674.10892.2.4.1.1.7 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsPeakUsage + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.8 + type: DisplayString + help: 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. - 1.3.6.1.4.1.674.10892.2.4.1.1.8 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsPeakTime + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.9 + type: DisplayString + help: 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. - 1.3.6.1.4.1.674.10892.2.4.1.1.9 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsMinUsage + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.10 + type: DisplayString + help: 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. - 1.3.6.1.4.1.674.10892.2.4.1.1.10 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsMinTime + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.11 + type: DisplayString + help: 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. - 1.3.6.1.4.1.674.10892.2.4.1.1.11 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsResetTime + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.12 + type: DisplayString + help: 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. - 1.3.6.1.4.1.674.10892.2.4.1.1.12 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsWattsReading + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.13 + type: DisplayString + help: 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). - 1.3.6.1.4.1.674.10892.2.4.1.1.13 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsAmpsReading + oid: 1.3.6.1.4.1.674.10892.2.4.1.1.14 + type: DisplayString + help: 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). - 1.3.6.1.4.1.674.10892.2.4.1.1.14 + indexes: + - labelname: drsChassisIndex + type: gauge + fixed_size: 1 + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsPSUChassisIndex + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.1 + type: gauge + help: 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. - 1.3.6.1.4.1.674.10892.2.4.2.1.1 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + - name: drsPSUIndex + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.2 + type: gauge + help: 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. - 1.3.6.1.4.1.674.10892.2.4.2.1.2 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + - name: drsPSULocation + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.3 + type: DisplayString + help: 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. - 1.3.6.1.4.1.674.10892.2.4.2.1.3 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + - name: drsPSUMonitoringCapable + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.4 + type: gauge + help: 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. - 1.3.6.1.4.1.674.10892.2.4.2.1.4 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + enum_values: + 1: absent + 2: none + 3: basic + - name: drsPSUVoltsReading + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.5 + type: DisplayString + help: 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. - 1.3.6.1.4.1.674.10892.2.4.2.1.5 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsPSUAmpsReading + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.6 + type: DisplayString + help: 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. - 1.3.6.1.4.1.674.10892.2.4.2.1.6 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + - name: drsPSUWattsReading + oid: 1.3.6.1.4.1.674.10892.2.4.2.1.7 + type: DisplayString + help: 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. - 1.3.6.1.4.1.674.10892.2.4.2.1.7 + indexes: + - labelname: drsPSUChassisIndex + type: gauge + fixed_size: 1 + - labelname: drsPSUIndex + type: gauge + regex_extracts: + "": + - value: $1 + regex: ^(?:(.*))$ + hpe: + walk: + - 1.3.6.1.4.1.232.1.2.2.1.1 + - 1.3.6.1.4.1.232.11 + - 1.3.6.1.4.1.232.14 + - 1.3.6.1.4.1.232.3.2.2.1 + - 1.3.6.1.4.1.232.3.2.3.1.1 + - 1.3.6.1.4.1.232.3.2.5.1.1 + - 1.3.6.1.4.1.232.5 + - 1.3.6.1.4.1.232.6.2.14.13.1.6 + - 1.3.6.1.4.1.232.6.2.15 + - 1.3.6.1.4.1.232.6.2.16 + - 1.3.6.1.4.1.232.6.2.17 + - 1.3.6.1.4.1.232.6.2.6.8.1 + - 1.3.6.1.4.1.232.6.2.9 + - 1.3.6.1.4.1.232.9.2.2 + metrics: + - name: cpqSeCpuUnitIndex + oid: 1.3.6.1.4.1.232.1.2.2.1.1.1 + type: gauge + help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuSlot + oid: 1.3.6.1.4.1.232.1.2.2.1.1.2 + type: gauge + help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuName + oid: 1.3.6.1.4.1.232.1.2.2.1.1.3 + type: DisplayString + help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuSpeed + oid: 1.3.6.1.4.1.232.1.2.2.1.1.4 + type: gauge + help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuStep + oid: 1.3.6.1.4.1.232.1.2.2.1.1.5 + type: gauge + help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuStatus + oid: 1.3.6.1.4.1.232.1.2.2.1.1.6 + type: gauge + help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unknown + 2: ok + 3: degraded + 4: failed + 5: disabled + - name: cpqSeCpuExtSpeed + oid: 1.3.6.1.4.1.232.1.2.2.1.1.7 + type: gauge + help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuDesigner + oid: 1.3.6.1.4.1.232.1.2.2.1.1.8 + type: gauge + help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unknown + 2: intel + 3: amd + 4: cyrix + 5: ti + 6: nexgen + 7: compaq + 8: samsung + 9: mitsubishi + 10: mips + - name: cpqSeCpuSocketNumber + oid: 1.3.6.1.4.1.232.1.2.2.1.1.9 + type: gauge + help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuThreshPassed + oid: 1.3.6.1.4.1.232.1.2.2.1.1.10 + type: gauge + help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unsupported + 2: "false" + 3: "true" + - name: cpqSeCpuHwLocation + oid: 1.3.6.1.4.1.232.1.2.2.1.1.11 + type: DisplayString + help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuCellTablePtr + oid: 1.3.6.1.4.1.232.1.2.2.1.1.12 + type: gauge + help: This is the index for the cell in cpqSeCellTable where this CPU is physically located. - 1.3.6.1.4.1.232.1.2.2.1.1.12 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuPowerpodStatus + oid: 1.3.6.1.4.1.232.1.2.2.1.1.13 + type: gauge + help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: notfailed + 2: failed + - name: cpqSeCpuArchitectureRevision + oid: 1.3.6.1.4.1.232.1.2.2.1.1.14 + type: DisplayString + help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuCore + oid: 1.3.6.1.4.1.232.1.2.2.1.1.15 + type: gauge + help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUSerialNumber + oid: 1.3.6.1.4.1.232.1.2.2.1.1.16 + type: DisplayString + help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUPartNumber + oid: 1.3.6.1.4.1.232.1.2.2.1.1.17 + type: DisplayString + help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUSerialNumberMfgr + oid: 1.3.6.1.4.1.232.1.2.2.1.1.18 + type: DisplayString + help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUPartNumberMfgr + oid: 1.3.6.1.4.1.232.1.2.2.1.1.19 + type: DisplayString + help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUCoreIndex + oid: 1.3.6.1.4.1.232.1.2.2.1.1.20 + type: gauge + help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUMaxSpeed + oid: 1.3.6.1.4.1.232.1.2.2.1.1.21 + type: gauge + help: This is the maximum internal speed in megahertz this processor can support - 1.3.6.1.4.1.232.1.2.2.1.1.21 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUCoreThreadIndex + oid: 1.3.6.1.4.1.232.1.2.2.1.1.22 + type: gauge + help: This is an unique number to identify the running threads in a CPU core. - 1.3.6.1.4.1.232.1.2.2.1.1.22 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUChipGenerationName + oid: 1.3.6.1.4.1.232.1.2.2.1.1.23 + type: DisplayString + help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCPUMultiThreadStatus + oid: 1.3.6.1.4.1.232.1.2.2.1.1.24 + type: gauge + help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unknown + 2: enabled + 3: disabled + - name: cpqSeCPUCoreMaxThreads + oid: 1.3.6.1.4.1.232.1.2.2.1.1.25 + type: gauge + help: This OID indicates the maximum number of threads that a cpu core is capable of. - 1.3.6.1.4.1.232.1.2.2.1.1.25 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuLowPowerStatus + oid: 1.3.6.1.4.1.232.1.2.2.1.1.26 + type: gauge + help: Servers like Itanium has capability to lower power supply to CPU if it is idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unknown + 2: lowpowered + 3: normalpowered + 4: highpowered + - name: cpqSeCpuPrimary + oid: 1.3.6.1.4.1.232.1.2.2.1.1.27 + type: gauge + help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary - 1.3.6.1.4.1.232.1.2.2.1.1.27 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + enum_values: + 1: unknown + 2: "false" + 3: "true" + - name: cpqSeCpuCoreSteppingText + oid: 1.3.6.1.4.1.232.1.2.2.1.1.28 + type: DisplayString + help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuCurrentPerformanceState + oid: 1.3.6.1.4.1.232.1.2.2.1.1.29 + type: gauge + help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuMinPerformanceState + oid: 1.3.6.1.4.1.232.1.2.2.1.1.30 + type: gauge + help: This OID returns the minimum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.30 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqSeCpuMaxPerformanceState + oid: 1.3.6.1.4.1.232.1.2.2.1.1.31 + type: gauge + help: This OID returns the maximum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.31 + indexes: + - labelname: cpqSeCpuUnitIndex + type: gauge + - name: cpqHoMibRevMajor + oid: 1.3.6.1.4.1.232.11.1.1 + type: gauge + help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1 + - name: cpqHoMibRevMinor + oid: 1.3.6.1.4.1.232.11.1.2 + type: gauge + help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2 + - name: cpqHoMibCondition + oid: 1.3.6.1.4.1.232.11.1.3 + type: gauge + help: The overall condition - 1.3.6.1.4.1.232.11.1.3 + enum_values: + 1: unknown + 2: ok + 3: degraded + 4: failed + - name: cpqHoOsCommonPollFreq + oid: 1.3.6.1.4.1.232.11.2.1.4.1 + type: gauge + help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1 + - name: cpqHoOsCommonModuleIndex + oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1 + type: gauge + help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1 + indexes: + - labelname: cpqHoOsCommonModuleIndex + type: gauge + - name: cpqHoOsCommonModuleName + oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2 + type: DisplayString + help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2 + indexes: + - labelname: cpqHoOsCommonModuleIndex + type: gauge + - name: cpqHoOsCommonModuleVersion + oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3 + type: DisplayString + help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3 + indexes: + - labelname: cpqHoOsCommonModuleIndex + type: gauge + - name: cpqHoOsCommonModuleDate + oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4 + type: OctetString + help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4 + indexes: + - labelname: cpqHoOsCommonModuleIndex + type: gauge + - name: cpqHoOsCommonModulePurpose + oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5 + type: DisplayString + help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5 + indexes: + - labelname: cpqHoOsCommonModuleIndex + type: gauge + - name: cpqHoName + oid: 1.3.6.1.4.1.232.11.2.2.1 + type: DisplayString + help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1 + - name: cpqHoVersion + oid: 1.3.6.1.4.1.232.11.2.2.2 + type: DisplayString + help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2 + - name: cpqHoDesc + oid: 1.3.6.1.4.1.232.11.2.2.3 + type: DisplayString + help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3 + - name: cpqHoOsType + oid: 1.3.6.1.4.1.232.11.2.2.4 + type: gauge + help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4 + enum_values: + 1: other + 2: netware + 3: windowsnt + 4: sco-unix + 5: unixware + 6: os-2 + 7: ms-dos + 8: dos-windows + 9: windows95 + 10: windows98 + 11: open-vms + 12: nsk + 13: windowsCE + 14: linux + 15: windows2000 + 16: tru64UNIX + 17: windows2003 + 18: windows2003-x64 + 19: solaris + 20: windows2003-ia64 + 21: windows2008 + 22: windows2008-x64 + 23: windows2008-ia64 + 24: vmware-esx + 25: vmware-esxi + 26: windows2012 + 27: windows7 + 28: windows7-x64 + 29: windows8 + 30: windows8-x64 + 31: windows81 + 32: windows81-x64 + 33: windowsxp + 34: windowsxp-x64 + 35: windowsvista + 36: windowsvista-x64 + 37: windows2008-r2 + 38: windows2012-r2 + 39: rhel + 40: rhel-64 + 41: solaris-64 + 42: sles + 43: sles-64 + 44: ubuntu + 45: ubuntu-64 + 46: debian + 47: debian-64 + 48: linux-64-bit + 49: other-64-bit + 50: centos-32bit + 51: centos-64bit + 52: oracle-linux32 + 53: oracle-linux64 + 54: apple-osx + 55: windows2016 + 56: nanoserver + 57: windows2019 + 58: windows10-x64 + 59: windows2022 + 60: azurestackhciOS-20h2 + 61: azurestackhciOS-21h2 + 62: azurestackhciOS-22h2 + - name: cpqHoTelnet + oid: 1.3.6.1.4.1.232.11.2.2.5 + type: gauge + help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5 + enum_values: + 1: other + 2: available + 3: notavailable + - name: cpqHoSystemRole + oid: 1.3.6.1.4.1.232.11.2.2.6 + type: DisplayString + help: The system role - 1.3.6.1.4.1.232.11.2.2.6 + - name: cpqHoSystemRoleDetail + oid: 1.3.6.1.4.1.232.11.2.2.7 + type: DisplayString + help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7 + - name: cpqHoCrashDumpState + oid: 1.3.6.1.4.1.232.11.2.2.8 + type: gauge + help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8 + enum_values: + 1: completememorydump + 2: kernelmemorydump + 3: smallmemorydump + 4: none + - name: cpqHoCrashDumpCondition + oid: 1.3.6.1.4.1.232.11.2.2.9 + type: gauge + help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHoCrashDumpMonitoring + oid: 1.3.6.1.4.1.232.11.2.2.10 + type: gauge + help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10 + enum_values: + 1: enabled + 2: disabled + - name: cpqHoMaxLogicalCPUSupported + oid: 1.3.6.1.4.1.232.11.2.2.11 + type: gauge + help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11 + - name: cpqHoSystemName + oid: 1.3.6.1.4.1.232.11.2.2.12 + type: DisplayString + help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12 + - name: cpqHosysDescr + oid: 1.3.6.1.4.1.232.11.2.2.13 + type: DisplayString + help: The value that would be returned in the RFC-1213 sysDescr MIB element - 1.3.6.1.4.1.232.11.2.2.13 + - name: cpqHoCpuUtilUnitIndex + oid: 1.3.6.1.4.1.232.11.2.3.1.1.1 + type: gauge + help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoCpuUtilMin + oid: 1.3.6.1.4.1.232.11.2.3.1.1.2 + type: gauge + help: The CPU utilization as a percentage of the theoretical maximum during the last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoCpuUtilFiveMin + oid: 1.3.6.1.4.1.232.11.2.3.1.1.3 + type: gauge + help: The CPU utilization as a percentage of the theoretical maximum during the last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoCpuUtilThirtyMin + oid: 1.3.6.1.4.1.232.11.2.3.1.1.4 + type: gauge + help: The CPU utilization as a percentage of the theoretical maximum during the last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoCpuUtilHour + oid: 1.3.6.1.4.1.232.11.2.3.1.1.5 + type: gauge + help: The CPU utilization as a percentage of the theoretical maximum during the last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoCpuUtilHwLocation + oid: 1.3.6.1.4.1.232.11.2.3.1.1.6 + type: DisplayString + help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6 + indexes: + - labelname: cpqHoCpuUtilUnitIndex + type: gauge + - name: cpqHoFileSysIndex + oid: 1.3.6.1.4.1.232.11.2.4.1.1.1 + type: gauge + help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysDesc + oid: 1.3.6.1.4.1.232.11.2.4.1.1.2 + type: DisplayString + help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysSpaceTotal + oid: 1.3.6.1.4.1.232.11.2.4.1.1.3 + type: gauge + help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysSpaceUsed + oid: 1.3.6.1.4.1.232.11.2.4.1.1.4 + type: gauge + help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysPercentSpaceUsed + oid: 1.3.6.1.4.1.232.11.2.4.1.1.5 + type: gauge + help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysAllocUnitsTotal + oid: 1.3.6.1.4.1.232.11.2.4.1.1.6 + type: gauge + help: The total number of files (directory entries) that can be stored on the file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysAllocUnitsUsed + oid: 1.3.6.1.4.1.232.11.2.4.1.1.7 + type: gauge + help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysStatus + oid: 1.3.6.1.4.1.232.11.2.4.1.1.8 + type: gauge + help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + enum_values: + 1: unknown + 2: ok + 3: degraded + 4: failed + - name: cpqHoFileSysShortDesc + oid: 1.3.6.1.4.1.232.11.2.4.1.1.9 + type: DisplayString + help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9 + indexes: + - labelname: cpqHoFileSysIndex + type: gauge + - name: cpqHoFileSysCondition + oid: 1.3.6.1.4.1.232.11.2.4.2 + type: gauge + help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2 + enum_values: + 1: unknown + 2: ok + 3: degraded + 4: failed + - name: cpqHoIfPhysMapIndex + oid: 1.3.6.1.4.1.232.11.2.5.1.1.1 + type: gauge + help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapSlot + oid: 1.3.6.1.4.1.232.11.2.5.1.1.2 + type: gauge + help: The number of the slot containing the physical hardware that implements this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapIoBaseAddr + oid: 1.3.6.1.4.1.232.11.2.5.1.1.3 + type: gauge + help: The base I/O address of the physical hardware that implements this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.3 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapIrq + oid: 1.3.6.1.4.1.232.11.2.5.1.1.4 + type: gauge + help: The number of the IRQ (interrupt) used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.4 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapDma + oid: 1.3.6.1.4.1.232.11.2.5.1.1.5 + type: gauge + help: The number of the DMA channel used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.5 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapMemBaseAddr + oid: 1.3.6.1.4.1.232.11.2.5.1.1.6 + type: gauge + help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapPort + oid: 1.3.6.1.4.1.232.11.2.5.1.1.7 + type: gauge + help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + - name: cpqHoIfPhysMapDuplexState + oid: 1.3.6.1.4.1.232.11.2.5.1.1.8 + type: gauge + help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + enum_values: + 1: other + 2: half + 3: full + - name: cpqHoIfPhysMapCondition + oid: 1.3.6.1.4.1.232.11.2.5.1.1.9 + type: gauge + help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9 + indexes: + - labelname: cpqHoIfPhysMapIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHoIfPhysMapOverallCondition + oid: 1.3.6.1.4.1.232.11.2.5.2 + type: gauge + help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHoSWRunningIndex + oid: 1.3.6.1.4.1.232.11.2.6.1.1.1 + type: gauge + help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningName + oid: 1.3.6.1.4.1.232.11.2.6.1.1.2 + type: DisplayString + help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningDesc + oid: 1.3.6.1.4.1.232.11.2.6.1.1.3 + type: DisplayString + help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningVersion + oid: 1.3.6.1.4.1.232.11.2.6.1.1.4 + type: DisplayString + help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningDate + oid: 1.3.6.1.4.1.232.11.2.6.1.1.5 + type: OctetString + help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningMonitor + oid: 1.3.6.1.4.1.232.11.2.6.1.1.6 + type: gauge + help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + enum_values: + 1: other + 2: start + 3: stop + 4: startAndStop + 5: count + 6: startAndCount + 7: countAndStop + 8: startCountAndStop + - name: cpqHoSWRunningState + oid: 1.3.6.1.4.1.232.11.2.6.1.1.7 + type: gauge + help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + enum_values: + 1: other + 2: started + 3: stopped + - name: cpqHoSWRunningCount + oid: 1.3.6.1.4.1.232.11.2.6.1.1.8 + type: gauge + help: For each process name, the number of instances of the process running on the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningCountMin + oid: 1.3.6.1.4.1.232.11.2.6.1.1.9 + type: gauge + help: This is the lower threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.9 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningCountMax + oid: 1.3.6.1.4.1.232.11.2.6.1.1.10 + type: gauge + help: This is the upper threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.10 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningEventTime + oid: 1.3.6.1.4.1.232.11.2.6.1.1.11 + type: OctetString + help: The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningStatus + oid: 1.3.6.1.4.1.232.11.2.6.1.1.12 + type: gauge + help: The overall alarm state of the resources managed by the software, or the software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + enum_values: + 1: unknown + 2: normal + 3: warning + 4: minor + 5: major + 6: critical + 7: disabled + - name: cpqHoSWRunningConfigStatus + oid: 1.3.6.1.4.1.232.11.2.6.1.1.13 + type: gauge + help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + enum_values: + 1: unknown + 2: starting + 3: initialized + 4: configured + 5: operational + - name: cpqHoSWRunningIdentifier + oid: 1.3.6.1.4.1.232.11.2.6.1.1.14 + type: DisplayString + help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + - name: cpqHoSWRunningRedundancyMode + oid: 1.3.6.1.4.1.232.11.2.6.1.1.15 + type: gauge + help: When the software is running in a high availability mode, the failover mode of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15 + indexes: + - labelname: cpqHoSWRunningIndex + type: gauge + enum_values: + 1: unknown + 2: master + 3: backup + 4: slave + - name: cpqHoSwRunningTrapDesc + oid: 1.3.6.1.4.1.232.11.2.6.2 + type: DisplayString + help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2 + - name: cpqHoSwVerNextIndex + oid: 1.3.6.1.4.1.232.11.2.7.1 + type: gauge + help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1 + - name: cpqHoSwVerIndex + oid: 1.3.6.1.4.1.232.11.2.7.2.1.1 + type: gauge + help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerStatus + oid: 1.3.6.1.4.1.232.11.2.7.2.1.2 + type: gauge + help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + enum_values: + 1: other + 2: loaded + 3: notloaded + - name: cpqHoSwVerType + oid: 1.3.6.1.4.1.232.11.2.7.2.1.3 + type: gauge + help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + enum_values: + 1: other + 2: driver + 3: agent + 4: sysutil + 5: application + 6: keyfile + 7: firmware + - name: cpqHoSwVerName + oid: 1.3.6.1.4.1.232.11.2.7.2.1.4 + type: DisplayString + help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerDescription + oid: 1.3.6.1.4.1.232.11.2.7.2.1.5 + type: DisplayString + help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerDate + oid: 1.3.6.1.4.1.232.11.2.7.2.1.6 + type: OctetString + help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerLocation + oid: 1.3.6.1.4.1.232.11.2.7.2.1.7 + type: DisplayString + help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerVersion + oid: 1.3.6.1.4.1.232.11.2.7.2.1.8 + type: DisplayString + help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerVersionBinary + oid: 1.3.6.1.4.1.232.11.2.7.2.1.9 + type: DisplayString + help: An string that specifies the version of this item based on the binary version resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9 + indexes: + - labelname: cpqHoSwVerIndex + type: gauge + - name: cpqHoSwVerAgentsVer + oid: 1.3.6.1.4.1.232.11.2.7.3 + type: DisplayString + help: A string that specifies the version of the Insight Management Agents running on the system. - 1.3.6.1.4.1.232.11.2.7.3 + - name: cpqHoGenericData + oid: 1.3.6.1.4.1.232.11.2.8.1 + type: DisplayString + help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1 + - name: cpqHoCriticalSoftwareUpdateData + oid: 1.3.6.1.4.1.232.11.2.8.2 + type: DisplayString + help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2 + - name: cpqHoSwPerfAppErrorDesc + oid: 1.3.6.1.4.1.232.11.2.9.1 + type: DisplayString + help: This string holds error information about the last application error that occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1 + - name: cpqHoMibStatusArray + oid: 1.3.6.1.4.1.232.11.2.10.1 + type: OctetString + help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1 + - name: cpqHoConfigChangedDate + oid: 1.3.6.1.4.1.232.11.2.10.2 + type: OctetString + help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2 + - name: cpqHoGUID + oid: 1.3.6.1.4.1.232.11.2.10.3 + type: OctetString + help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3 + - name: cpqHoCodeServer + oid: 1.3.6.1.4.1.232.11.2.10.4 + type: gauge + help: This item indicates how many code server shares are currently configured on the system - 1.3.6.1.4.1.232.11.2.10.4 + - name: cpqHoWebMgmtPort + oid: 1.3.6.1.4.1.232.11.2.10.5 + type: gauge + help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5 + - name: cpqHoGUIDCanonical + oid: 1.3.6.1.4.1.232.11.2.10.6 + type: OctetString + help: The globally unique identifier in canonical format of this physical server - 1.3.6.1.4.1.232.11.2.10.6 + - name: cpqHoMibHealthStatusArray + oid: 1.3.6.1.4.1.232.11.2.10.7 + type: OctetString + help: 'The MIB Health Status Array is an array of status values representing an overall status in element 0 follwed by server and storage status values as follows: Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7' + - name: cpqHoTrapFlags + oid: 1.3.6.1.4.1.232.11.2.11.1 + type: gauge + help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1 + - name: cpqHoClientLastModified + oid: 1.3.6.1.4.1.232.11.2.12.1 + type: OctetString + help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1 + - name: cpqHoClientDelete + oid: 1.3.6.1.4.1.232.11.2.12.2 + type: DisplayString + help: Setting this variable to the name of a client in the client table will cause that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2 + - name: cpqHoClientIndex + oid: 1.3.6.1.4.1.232.11.2.12.3.1.1 + type: gauge + help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoClientName + oid: 1.3.6.1.4.1.232.11.2.12.3.1.2 + type: DisplayString + help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoClientIpxAddress + oid: 1.3.6.1.4.1.232.11.2.12.3.1.3 + type: OctetString + help: The IPX address for this client, all octets should be set to 0xff if this machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoClientIpAddress + oid: 1.3.6.1.4.1.232.11.2.12.3.1.4 + type: InetAddressIPv4 + help: The IP address for this client, all octets should be set to 0xff if this machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoClientCommunity + oid: 1.3.6.1.4.1.232.11.2.12.3.1.5 + type: DisplayString + help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoClientID + oid: 1.3.6.1.4.1.232.11.2.12.3.1.6 + type: OctetString + help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6 + indexes: + - labelname: cpqHoClientIndex + type: gauge + - name: cpqHoPhysicalMemorySize + oid: 1.3.6.1.4.1.232.11.2.13.1 + type: gauge + help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1 + - name: cpqHoPhysicalMemoryFree + oid: 1.3.6.1.4.1.232.11.2.13.2 + type: gauge + help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2 + - name: cpqHoPagingMemorySize + oid: 1.3.6.1.4.1.232.11.2.13.3 + type: gauge + help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3 + - name: cpqHoPagingMemoryFree + oid: 1.3.6.1.4.1.232.11.2.13.4 + type: gauge + help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4 + - name: cpqHoBootPagingFileSize + oid: 1.3.6.1.4.1.232.11.2.13.5 + type: DisplayString + help: The paging file size of the boot volume in the format xxxMB or xxxGB, where xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5 + - name: cpqHoBootPagingFileMinimumSize + oid: 1.3.6.1.4.1.232.11.2.13.6 + type: DisplayString + help: Minimum paging file size of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6 + - name: cpqHoBootPagingFileVolumeFreeSpace + oid: 1.3.6.1.4.1.232.11.2.13.7 + type: DisplayString + help: Free space of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.7 + - name: cpqHoFwVerIndex + oid: 1.3.6.1.4.1.232.11.2.14.1.1.1 + type: gauge + help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerCategory + oid: 1.3.6.1.4.1.232.11.2.14.1.1.2 + type: gauge + help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + enum_values: + 1: other + 2: storage + 3: nic + 4: rib + 5: system + - name: cpqHoFwVerDeviceType + oid: 1.3.6.1.4.1.232.11.2.14.1.1.3 + type: gauge + help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + enum_values: + 1: other + 2: internalArrayController + 3: fibreArrayController + 4: scsiController + 5: fibreChannelTapeController + 6: modularDataRouter + 7: ideCdRomDrive + 8: ideDiskDrive + 9: scsiCdRom-ScsiAttached + 10: scsiDiskDrive-ScsiAttached + 11: scsiTapeDrive-ScsiAttached + 12: scsiTapeLibrary-ScsiAttached + 13: scsiDiskDrive-ArrayAttached + 14: scsiTapeDrive-ArrayAttached + 15: scsiTapeLibrary-ArrayAttached + 16: scsiDiskDrive-FibreAttached + 17: scsiTapeDrive-FibreAttached + 18: scsiTapeLibrary-FibreAttached + 19: scsiEnclosureBackplaneRom-ScsiAttached + 20: scsiEnclosureBackplaneRom-ArrayAttached + 21: scsiEnclosureBackplaneRom-FibreAttached + 22: scsiEnclosureBackplaneRom-ra4x00 + 23: systemRom + 24: networkInterfaceController + 25: remoteInsightBoard + 26: sasDiskDrive-SasAttached + 27: sataDiskDrive-SataAttached + 28: usbController + 29: sasControllerAdapter + 30: sataControllerAdapter + 31: systemDevice + 32: fibreChannelHba + 33: convergedNetworkAdapter + 34: ideController + - name: cpqHoFwVerDisplayName + oid: 1.3.6.1.4.1.232.11.2.14.1.1.4 + type: DisplayString + help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerVersion + oid: 1.3.6.1.4.1.232.11.2.14.1.1.5 + type: DisplayString + help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerLocation + oid: 1.3.6.1.4.1.232.11.2.14.1.1.6 + type: DisplayString + help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerXmlString + oid: 1.3.6.1.4.1.232.11.2.14.1.1.7 + type: DisplayString + help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerKeyString + oid: 1.3.6.1.4.1.232.11.2.14.1.1.8 + type: DisplayString + help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + - name: cpqHoFwVerUpdateMethod + oid: 1.3.6.1.4.1.232.11.2.14.1.1.9 + type: gauge + help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9 + indexes: + - labelname: cpqHoFwVerIndex + type: gauge + enum_values: + 1: other + 2: noUpdate + 3: softwareflash + 4: replacePhysicalRom + - name: cpqHoHWInfoPlatform + oid: 1.3.6.1.4.1.232.11.2.15.1 + type: gauge + help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1 + enum_values: + 1: unknown + 2: cellular + 3: foundation + 4: virtualMachine + 5: serverBlade + - name: cpqPwrWarnType + oid: 1.3.6.1.4.1.232.11.2.16.1 + type: DisplayString + help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1 + - name: cpqPwrWarnThreshold + oid: 1.3.6.1.4.1.232.11.2.16.2 + type: gauge + help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2 + - name: cpqPwrWarnDuration + oid: 1.3.6.1.4.1.232.11.2.16.3 + type: gauge + help: Duration that power usage must be exceeded before warning (in minutes). - 1.3.6.1.4.1.232.11.2.16.3 + - name: cpqSerialNum + oid: 1.3.6.1.4.1.232.11.2.16.4 + type: DisplayString + help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4 + - name: cpqServerUUID + oid: 1.3.6.1.4.1.232.11.2.16.5 + type: DisplayString + help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5 + - name: cpqIdeMibRevMajor + oid: 1.3.6.1.4.1.232.14.1.1 + type: gauge + help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1 + - name: cpqIdeMibRevMinor + oid: 1.3.6.1.4.1.232.14.1.2 + type: gauge + help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2 + - name: cpqIdeMibCondition + oid: 1.3.6.1.4.1.232.14.1.3 + type: gauge + help: The overall condition - 1.3.6.1.4.1.232.14.1.3 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeOsCommonPollFreq + oid: 1.3.6.1.4.1.232.14.2.1.4.1 + type: gauge + help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1 + - name: cpqIdeOsCommonModuleIndex + oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1 + type: gauge + help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1 + indexes: + - labelname: cpqIdeOsCommonModuleIndex + type: gauge + - name: cpqIdeOsCommonModuleName + oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2 + type: DisplayString + help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2 + indexes: + - labelname: cpqIdeOsCommonModuleIndex + type: gauge + - name: cpqIdeOsCommonModuleVersion + oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3 + type: DisplayString + help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3 + indexes: + - labelname: cpqIdeOsCommonModuleIndex + type: gauge + - name: cpqIdeOsCommonModuleDate + oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4 + type: OctetString + help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4 + indexes: + - labelname: cpqIdeOsCommonModuleIndex + type: gauge + - name: cpqIdeOsCommonModulePurpose + oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5 + type: DisplayString + help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5 + indexes: + - labelname: cpqIdeOsCommonModuleIndex + type: gauge + - name: cpqIdeIdentIndex + oid: 1.3.6.1.4.1.232.14.2.2.1.1.1 + type: gauge + help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + - name: cpqIdeIdentModel + oid: 1.3.6.1.4.1.232.14.2.2.1.1.2 + type: DisplayString + help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + - name: cpqIdeIdentSerNum + oid: 1.3.6.1.4.1.232.14.2.2.1.1.3 + type: DisplayString + help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + - name: cpqIdeIdentFWVers + oid: 1.3.6.1.4.1.232.14.2.2.1.1.4 + type: DisplayString + help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + - name: cpqIdeIdentCondition + oid: 1.3.6.1.4.1.232.14.2.2.1.1.5 + type: gauge + help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeIdentErrorNumber + oid: 1.3.6.1.4.1.232.14.2.2.1.1.6 + type: DisplayString + help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + - name: cpqIdeIdentType + oid: 1.3.6.1.4.1.232.14.2.2.1.1.7 + type: gauge + help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: disk + 3: tape + 4: printer + 5: processor + 6: wormDrive + 7: cd-rom + 8: scanner + 9: optical + 10: jukeBox + 11: commDev + - name: cpqIdeIdentTypeExtended + oid: 1.3.6.1.4.1.232.14.2.2.1.1.8 + type: gauge + help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: pdcd + 3: removableDisk + - name: cpqIdeIdentCondition2 + oid: 1.3.6.1.4.1.232.14.2.2.1.1.9 + type: gauge + help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeIdentStatus + oid: 1.3.6.1.4.1.232.14.2.2.1.1.10 + type: gauge + help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: preFailureDegraded + 4: ultraAtaDegraded + - name: cpqIdeIdentUltraAtaAvailability + oid: 1.3.6.1.4.1.232.14.2.2.1.1.11 + type: gauge + help: This describes the availability of Ultra ATA transfers between this device and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11 + indexes: + - labelname: cpqIdeIdentIndex + type: gauge + enum_values: + 1: other + 2: noNotSupportedByDeviceAndController + 3: noNotSupportedByDevice + 4: noNotSupportedByController + 5: noDisabledInSetup + 6: yesEnabledInSetup + - name: cpqIdeControllerIndex + oid: 1.3.6.1.4.1.232.14.2.3.1.1.1 + type: gauge + help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerOverallCondition + oid: 1.3.6.1.4.1.232.14.2.3.1.1.2 + type: gauge + help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeControllerModel + oid: 1.3.6.1.4.1.232.14.2.3.1.1.3 + type: DisplayString + help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerFwRev + oid: 1.3.6.1.4.1.232.14.2.3.1.1.4 + type: DisplayString + help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerSlot + oid: 1.3.6.1.4.1.232.14.2.3.1.1.5 + type: gauge + help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerStatus + oid: 1.3.6.1.4.1.232.14.2.3.1.1.6 + type: gauge + help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + - name: cpqIdeControllerCondition + oid: 1.3.6.1.4.1.232.14.2.3.1.1.7 + type: gauge + help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeControllerSerialNumber + oid: 1.3.6.1.4.1.232.14.2.3.1.1.8 + type: DisplayString + help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerHwLocation + oid: 1.3.6.1.4.1.232.14.2.3.1.1.9 + type: DisplayString + help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeControllerPciLocation + oid: 1.3.6.1.4.1.232.14.2.3.1.1.10 + type: DisplayString + help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10 + indexes: + - labelname: cpqIdeControllerIndex + type: gauge + - name: cpqIdeAtaDiskControllerIndex + oid: 1.3.6.1.4.1.232.14.2.4.1.1.1 + type: gauge + help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskIndex + oid: 1.3.6.1.4.1.232.14.2.4.1.1.2 + type: gauge + help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskModel + oid: 1.3.6.1.4.1.232.14.2.4.1.1.3 + type: DisplayString + help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskFwRev + oid: 1.3.6.1.4.1.232.14.2.4.1.1.4 + type: DisplayString + help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskSerialNumber + oid: 1.3.6.1.4.1.232.14.2.4.1.1.5 + type: DisplayString + help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskStatus + oid: 1.3.6.1.4.1.232.14.2.4.1.1.6 + type: gauge + help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: smartError + 4: failed + 5: ssdWearOut + 6: removed + 7: inserted + - name: cpqIdeAtaDiskCondition + oid: 1.3.6.1.4.1.232.14.2.4.1.1.7 + type: gauge + help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeAtaDiskCapacity + oid: 1.3.6.1.4.1.232.14.2.4.1.1.8 + type: gauge + help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskSmartEnabled + oid: 1.3.6.1.4.1.232.14.2.4.1.1.9 + type: gauge + help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqIdeAtaDiskTransferMode + oid: 1.3.6.1.4.1.232.14.2.4.1.1.10 + type: gauge + help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: pioMode0 + 3: pioMode1 + 4: pioMode2 + 5: pioMode3 + 6: pioMode4 + 7: dmaMode0 + 8: dmaMode1 + 9: dmaMode2 + 10: ultraDmaMode0 + 11: ultraDmaMode1 + 12: ultraDmaMode2 + 13: ultraDmaMode3 + 14: ultraDmaMode4 + 15: ultraDmaMode5 + - name: cpqIdeAtaDiskChannel + oid: 1.3.6.1.4.1.232.14.2.4.1.1.11 + type: gauge + help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: channel0 + 3: channel1 + 4: serial + - name: cpqIdeAtaDiskNumber + oid: 1.3.6.1.4.1.232.14.2.4.1.1.12 + type: gauge + help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: device0 + 3: device1 + 4: sataDevice0 + 5: sataDevice1 + 6: sataDevice2 + 7: sataDevice3 + 8: sataDevice4 + 9: sataDevice5 + 10: sataDevice6 + 11: sataDevice7 + 12: sataDevice8 + 13: sataDevice9 + 14: sataDevice10 + 15: sataDevice11 + 16: sataDevice12 + 17: sataDevice13 + 18: sataDevice14 + 19: sataDevice15 + 20: sataDevice16 + 21: bay1 + 22: bay2 + 23: bay3 + 24: bay4 + 25: bay5 + 26: bay6 + 27: bay7 + 28: bay8 + 29: bay9 + 30: bay10 + 31: bay11 + 32: bay12 + 33: bay13 + 34: bay14 + 35: bay15 + 36: bay16 + 37: bay17 + 38: bay18 + 39: bay19 + 40: bay20 + 41: bay21 + 42: bay22 + 43: bay23 + 44: bay24 + - name: cpqIdeAtaDiskLogicalDriveMember + oid: 1.3.6.1.4.1.232.14.2.4.1.1.13 + type: gauge + help: Logical Drive Membership? other(1) The agent cannot determine if the ATA disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqIdeAtaDiskIsSpare + oid: 1.3.6.1.4.1.232.14.2.4.1.1.14 + type: gauge + help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a spare - 1.3.6.1.4.1.232.14.2.4.1.1.14 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqIdeAtaDiskOsName + oid: 1.3.6.1.4.1.232.14.2.4.1.1.15 + type: DisplayString + help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskType + oid: 1.3.6.1.4.1.232.14.2.4.1.1.16 + type: gauge + help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: ata + 3: sata + - name: cpqIdeAtaDiskSataVersion + oid: 1.3.6.1.4.1.232.14.2.4.1.1.17 + type: gauge + help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: sataOne + 3: sataTwo + - name: cpqIdeAtaDiskMediaType + oid: 1.3.6.1.4.1.232.14.2.4.1.1.18 + type: gauge + help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: rotatingPlatters + 3: solidState + - name: cpqIdeAtaDiskSSDWearStatus + oid: 1.3.6.1.4.1.232.14.2.4.1.1.19 + type: gauge + help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: fiftySixDayThreshold + 4: fivePercentThreshold + 5: twoPercentThreshold + 6: ssdWearOut + - name: cpqIdeAtaDiskPowerOnHours + oid: 1.3.6.1.4.1.232.14.2.4.1.1.20 + type: counter + help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskSSDPercntEndrnceUsed + oid: 1.3.6.1.4.1.232.14.2.4.1.1.21 + type: gauge + help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskSSDEstTimeRemainingHours + oid: 1.3.6.1.4.1.232.14.2.4.1.1.22 + type: counter + help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskCurrTemperature + oid: 1.3.6.1.4.1.232.14.2.4.1.1.23 + type: gauge + help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskTemperatureThreshold + oid: 1.3.6.1.4.1.232.14.2.4.1.1.24 + type: gauge + help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskMaximumOperatingTemp + oid: 1.3.6.1.4.1.232.14.2.4.1.1.25 + type: gauge + help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer, in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskDestructiveOperatingTemp + oid: 1.3.6.1.4.1.232.14.2.4.1.1.26 + type: gauge + help: SATA Physical Drive Destructive Operating Temperature, as specified by the manufacturer, in degrees Celsius, which if exceeded can cause damage to the drive - 1.3.6.1.4.1.232.14.2.4.1.1.26 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskLocation + oid: 1.3.6.1.4.1.232.14.2.4.1.1.27 + type: DisplayString + help: Location of Disk Drive - 1.3.6.1.4.1.232.14.2.4.1.1.27 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskCapacityHighBytes + oid: 1.3.6.1.4.1.232.14.2.4.1.1.28 + type: counter + help: ATA Disk Capacity in Bytes (high) - 1.3.6.1.4.1.232.14.2.4.1.1.28 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaDiskCapacityLowBytes + oid: 1.3.6.1.4.1.232.14.2.4.1.1.29 + type: counter + help: ATA Disk Capacity in Bytes (low) - 1.3.6.1.4.1.232.14.2.4.1.1.29 + indexes: + - labelname: cpqIdeAtaDiskControllerIndex + type: gauge + - labelname: cpqIdeAtaDiskIndex + type: gauge + - name: cpqIdeAtaEraseFailureType + oid: 1.3.6.1.4.1.232.14.2.4.2 + type: gauge + help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2 + enum_values: + 1: secureEraseFailed + 2: secureEraseNotSupported + 3: noEraseSupported + - name: cpqIdeAtapiDeviceControllerIndex + oid: 1.3.6.1.4.1.232.14.2.5.1.1.1 + type: gauge + help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + - name: cpqIdeAtapiDeviceIndex + oid: 1.3.6.1.4.1.232.14.2.5.1.1.2 + type: gauge + help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + - name: cpqIdeAtapiDeviceModel + oid: 1.3.6.1.4.1.232.14.2.5.1.1.3 + type: DisplayString + help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + - name: cpqIdeAtapiDeviceFwRev + oid: 1.3.6.1.4.1.232.14.2.5.1.1.4 + type: DisplayString + help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + - name: cpqIdeAtapiDeviceType + oid: 1.3.6.1.4.1.232.14.2.5.1.1.5 + type: gauge + help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + enum_values: + 1: other + 2: disk + 3: tape + 4: printer + 5: processor + 6: wormDrive + 7: cd-rom + 8: scanner + 9: optical + 10: jukeBox + 11: commDev + - name: cpqIdeAtapiDeviceTypeExtended + oid: 1.3.6.1.4.1.232.14.2.5.1.1.6 + type: gauge + help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + enum_values: + 1: other + 2: pdcd + 3: removableDisk + - name: cpqIdeAtapiDeviceChannel + oid: 1.3.6.1.4.1.232.14.2.5.1.1.7 + type: gauge + help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + enum_values: + 1: other + 2: channel0 + 3: channel1 + - name: cpqIdeAtapiDeviceNumber + oid: 1.3.6.1.4.1.232.14.2.5.1.1.8 + type: gauge + help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8 + indexes: + - labelname: cpqIdeAtapiDeviceControllerIndex + type: gauge + - labelname: cpqIdeAtapiDeviceIndex + type: gauge + enum_values: + 1: other + 2: device0 + 3: device1 + - name: cpqIdeLogicalDriveControllerIndex + oid: 1.3.6.1.4.1.232.14.2.6.1.1.1 + type: gauge + help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveIndex + oid: 1.3.6.1.4.1.232.14.2.6.1.1.2 + type: gauge + help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveRaidLevel + oid: 1.3.6.1.4.1.232.14.2.6.1.1.3 + type: gauge + help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + enum_values: + 1: other + 2: raid0 + 3: raid1 + 4: raid0plus1 + 5: raid5 + 6: raid15 + 7: volume + - name: cpqIdeLogicalDriveCapacity + oid: 1.3.6.1.4.1.232.14.2.6.1.1.4 + type: gauge + help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveStatus + oid: 1.3.6.1.4.1.232.14.2.6.1.1.5 + type: gauge + help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: rebuilding + 5: failed + - name: cpqIdeLogicalDriveCondition + oid: 1.3.6.1.4.1.232.14.2.6.1.1.6 + type: gauge + help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqIdeLogicalDriveDiskIds + oid: 1.3.6.1.4.1.232.14.2.6.1.1.7 + type: OctetString + help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveStripeSize + oid: 1.3.6.1.4.1.232.14.2.6.1.1.8 + type: gauge + help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveSpareIds + oid: 1.3.6.1.4.1.232.14.2.6.1.1.9 + type: OctetString + help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveRebuildingDisk + oid: 1.3.6.1.4.1.232.14.2.6.1.1.10 + type: gauge + help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqIdeLogicalDriveOsName + oid: 1.3.6.1.4.1.232.14.2.6.1.1.11 + type: DisplayString + help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11 + indexes: + - labelname: cpqIdeLogicalDriveControllerIndex + type: gauge + - labelname: cpqIdeLogicalDriveIndex + type: gauge + - name: cpqDaCntlrIndex + oid: 1.3.6.1.4.1.232.3.2.2.1.1.1 + type: gauge + help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrModel + oid: 1.3.6.1.4.1.232.3.2.2.1.1.2 + type: gauge + help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ida + 3: idaExpansion + 4: ida-2 + 5: smart + 6: smart-2e + 7: smart-2p + 8: smart-2sl + 9: smart-3100es + 10: smart-3200 + 11: smart-2dh + 12: smart-221 + 13: sa-4250es + 14: sa-4200 + 15: sa-integrated + 16: sa-431 + 17: sa-5300 + 18: raidLc2 + 19: sa-5i + 20: sa-532 + 21: sa-5312 + 22: sa-641 + 23: sa-642 + 24: sa-6400 + 25: sa-6400em + 26: sa-6i + 27: sa-generic + 29: sa-p600 + 30: sa-p400 + 31: sa-e200 + 32: sa-e200i + 33: sa-p400i + 34: sa-p800 + 35: sa-e500 + 36: sa-p700m + 37: sa-p212 + 38: sa-p410 + 39: sa-p410i + 40: sa-p411 + 41: sa-b110i + 42: sa-p712m + 43: sa-p711m + 44: sa-p812 + 45: sw-1210m + 46: sa-p220i + 47: sa-p222 + 48: sa-p420 + 49: sa-p420i + 50: sa-p421 + 51: sa-b320i + 52: sa-p822 + 53: sa-p721m + 54: sa-b120i + 55: hps-1224 + 56: hps-1228 + 57: hps-1228m + 58: sa-p822se + 59: hps-1224e + 60: hps-1228e + 61: hps-1228em + 62: sa-p230i + 63: sa-p430i + 64: sa-p430 + 65: sa-p431 + 66: sa-p731m + 67: sa-p830i + 68: sa-p830 + 69: sa-p831 + 70: sa-p530 + 71: sa-p531 + 72: sa-p244br + 73: sa-p246br + 74: sa-p440 + 75: sa-p440ar + 76: sa-p441 + 77: sa-p741m + 78: sa-p840 + 79: sa-p841 + 80: sh-h240ar + 81: sh-h244br + 82: sh-h240 + 83: sh-h241 + 84: sa-b140i + 85: sh-generic + 86: sa-p240nr + 87: sh-h240nr + 88: sa-p840ar + 89: sa-p542d + 90: s100i + 91: e208i-p + 92: e208i-a + 93: e208i-c + 94: e208e-p + 95: p204i-b + 96: p204i-c + 97: p408i-p + 98: p408i-a + 99: p408e-p + 100: p408i-c + 101: p408e-m + 102: p416ie-m + 103: p816i-a + 104: p408i-sb + - name: cpqDaCntlrFWRev + oid: 1.3.6.1.4.1.232.3.2.2.1.1.3 + type: DisplayString + help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrStndIntr + oid: 1.3.6.1.4.1.232.3.2.2.1.1.4 + type: gauge + help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: primary + 3: secondary + 4: disabled + 5: unavailable + - name: cpqDaCntlrSlot + oid: 1.3.6.1.4.1.232.3.2.2.1.1.5 + type: gauge + help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrCondition + oid: 1.3.6.1.4.1.232.3.2.2.1.1.6 + type: gauge + help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqDaCntlrProductRev + oid: 1.3.6.1.4.1.232.3.2.2.1.1.7 + type: DisplayString + help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrPartnerSlot + oid: 1.3.6.1.4.1.232.3.2.2.1.1.8 + type: gauge + help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrCurrentRole + oid: 1.3.6.1.4.1.232.3.2.2.1.1.9 + type: gauge + help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: notDuplexed + 3: active + 4: backup + 5: asymActiveActive + - name: cpqDaCntlrBoardStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.10 + type: gauge + help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: generalFailure + 4: cableProblem + 5: poweredOff + 6: cacheModuleMissing + 7: degraded + - name: cpqDaCntlrPartnerBoardStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.11 + type: gauge + help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: generalFailure + 4: cableProblem + 5: poweredOff + - name: cpqDaCntlrBoardCondition + oid: 1.3.6.1.4.1.232.3.2.2.1.1.12 + type: gauge + help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqDaCntlrPartnerBoardCondition + oid: 1.3.6.1.4.1.232.3.2.2.1.1.13 + type: gauge + help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqDaCntlrDriveOwnership + oid: 1.3.6.1.4.1.232.3.2.2.1.1.14 + type: gauge + help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: owner + 3: notOwner + - name: cpqDaCntlrSerialNumber + oid: 1.3.6.1.4.1.232.3.2.2.1.1.15 + type: DisplayString + help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrRedundancyType + oid: 1.3.6.1.4.1.232.3.2.2.1.1.16 + type: gauge + help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: notRedundant + 3: driverDuplexing + 4: fwActiveStandby + 5: fwPrimarySecondary + 6: fwActiveActive + - name: cpqDaCntlrRedundancyError + oid: 1.3.6.1.4.1.232.3.2.2.1.1.17 + type: gauge + help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: noFailure + 3: noRedundantController + 4: differentHardware + 5: noLink + 6: differentFirmware + 7: differentCache + 8: otherCacheFailure + 9: noDrives + 10: otherNoDrives + 11: unsupportedDrives + 12: expandInProgress + - name: cpqDaCntlrAccessModuleStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.18 + type: gauge + help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: notPresent + 4: badSignature + 5: badChecksum + 6: fullyFunctional + 7: upgradeFirmware + - name: cpqDaCntlrDaughterBoardType + oid: 1.3.6.1.4.1.232.3.2.2.1.1.19 + type: gauge + help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: notPresent + 4: scsiBoardPresent + 5: fibreBoardPresent + 6: arrayExpansionModulePresent + - name: cpqDaCntlrHwLocation + oid: 1.3.6.1.4.1.232.3.2.2.1.1.20 + type: DisplayString + help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrNumberOfBuses + oid: 1.3.6.1.4.1.232.3.2.2.1.1.21 + type: gauge + help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrBlinkTime + oid: 1.3.6.1.4.1.232.3.2.2.1.1.22 + type: counter + help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrRebuildPriority + oid: 1.3.6.1.4.1.232.3.2.2.1.1.23 + type: gauge + help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: low + 3: medium + 4: high + 5: mediumHigh + - name: cpqDaCntlrExpandPriority + oid: 1.3.6.1.4.1.232.3.2.2.1.1.24 + type: gauge + help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: low + 3: medium + 4: high + - name: cpqDaCntlrNumberOfInternalPorts + oid: 1.3.6.1.4.1.232.3.2.2.1.1.25 + type: gauge + help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrNumberOfExternalPorts + oid: 1.3.6.1.4.1.232.3.2.2.1.1.26 + type: gauge + help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrDriveWriteCacheState + oid: 1.3.6.1.4.1.232.3.2.2.1.1.27 + type: gauge + help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: disabled + 3: enabled + - name: cpqDaCntlrPartnerSerialNumber + oid: 1.3.6.1.4.1.232.3.2.2.1.1.28 + type: DisplayString + help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrOptionRomRev + oid: 1.3.6.1.4.1.232.3.2.2.1.1.29 + type: DisplayString + help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrHbaFWRev + oid: 1.3.6.1.4.1.232.3.2.2.1.1.30 + type: DisplayString + help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrHBAModeOptionRomRev + oid: 1.3.6.1.4.1.232.3.2.2.1.1.31 + type: DisplayString + help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrCurrentTemp + oid: 1.3.6.1.4.1.232.3.2.2.1.1.32 + type: gauge + help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrLastLockupCode + oid: 1.3.6.1.4.1.232.3.2.2.1.1.33 + type: gauge + help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + - name: cpqDaCntlrEncryptionStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.34 + type: gauge + help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: notEnabled + 3: enabledLocalKeyMode + 4: enabledRemoteKeyManagerMode + - name: cpqDaCntlrASICEncptSelfTestStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.35 + type: gauge + help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: selfTestsPass + 3: selfTestsFailed + - name: cpqDaCntlrEncryptCspNvramStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.36 + type: gauge + help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: detectionFailed + - name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.37 + type: gauge + help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: "false" + 3: "true" + - name: cpqDaCntlrEncryptCntlrPwdSetStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.38 + type: gauge + help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: "false" + 3: "true" + - name: cpqDaCntlrEncryptCntlrPwdAvailStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.39 + type: gauge + help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: passwordMissing + 3: passwordActive + - name: cpqDaCntlrUnencryptedLogDrvCreationPolicy + oid: 1.3.6.1.4.1.232.3.2.2.1.1.40 + type: gauge + help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: "false" + 3: "true" + - name: cpqDaCntlrEncryptedLogDrvCreationPolicy + oid: 1.3.6.1.4.1.232.3.2.2.1.1.41 + type: gauge + help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: "false" + 3: "true" + - name: cpqDaCntlrEncryptFWLockStatus + oid: 1.3.6.1.4.1.232.3.2.2.1.1.42 + type: gauge + help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: "false" + 3: "true" + - name: cpqDaCntlrOperatingMode + oid: 1.3.6.1.4.1.232.3.2.2.1.1.43 + type: gauge + help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43 + indexes: + - labelname: cpqDaCntlrIndex + type: gauge + enum_values: + 1: other + 2: smartArrayMode + 3: smartHbaMode + 4: mixedMode + - name: cpqDaLogDrvCntlrIndex + oid: 1.3.6.1.4.1.232.3.2.3.1.1.1 + type: gauge + help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvIndex + oid: 1.3.6.1.4.1.232.3.2.3.1.1.2 + type: gauge + help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvFaultTol + oid: 1.3.6.1.4.1.232.3.2.3.1.1.3 + type: gauge + help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: none + 3: mirroring + 4: dataGuard + 5: distribDataGuard + 7: advancedDataGuard + 8: raid50 + 9: raid60 + 10: raid1Adm + 11: raid10Adm + 12: raid10 + - name: cpqDaLogDrvStatus + oid: 1.3.6.1.4.1.232.3.2.3.1.1.4 + type: gauge + help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + 4: unconfigured + 5: recovering + 6: readyForRebuild + 7: rebuilding + 8: wrongDrive + 9: badConnect + 10: overheating + 11: shutdown + 12: expanding + 13: notAvailable + 14: queuedForExpansion + 15: multipathAccessDegraded + 16: erasing + 17: predictiveSpareRebuildReady + 18: rapidParityInitInProgress + 19: rapidParityInitPending + 20: noAccessEncryptedNoCntlrKey + 21: unencryptedToEncryptedInProgress + 22: newLogDrvKeyRekeyInProgress + 23: noAccessEncryptedCntlrEncryptnNotEnbld + 24: unencryptedToEncryptedNotStarted + 25: newLogDrvKeyRekeyRequestReceived + 26: unsupported + 27: offline + 28: sedQualInProgrss + 29: sedQualFailed + - name: cpqDaLogDrvAutoRel + oid: 1.3.6.1.4.1.232.3.2.3.1.1.5 + type: gauge + help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvRebuildBlks + oid: 1.3.6.1.4.1.232.3.2.3.1.1.6 + type: counter + help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvHasAccel + oid: 1.3.6.1.4.1.232.3.2.3.1.1.7 + type: gauge + help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: unavailable + 3: enabled + 4: disabled + - name: cpqDaLogDrvAvailSpares + oid: 1.3.6.1.4.1.232.3.2.3.1.1.8 + type: OctetString + help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvSize + oid: 1.3.6.1.4.1.232.3.2.3.1.1.9 + type: gauge + help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvPhyDrvIDs + oid: 1.3.6.1.4.1.232.3.2.3.1.1.10 + type: OctetString + help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvCondition + oid: 1.3.6.1.4.1.232.3.2.3.1.1.11 + type: gauge + help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqDaLogDrvPercentRebuild + oid: 1.3.6.1.4.1.232.3.2.3.1.1.12 + type: gauge + help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvStripeSize + oid: 1.3.6.1.4.1.232.3.2.3.1.1.13 + type: gauge + help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvOsName + oid: 1.3.6.1.4.1.232.3.2.3.1.1.14 + type: DisplayString + help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvBlinkTime + oid: 1.3.6.1.4.1.232.3.2.3.1.1.15 + type: counter + help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvSpareReplaceMap + oid: 1.3.6.1.4.1.232.3.2.3.1.1.16 + type: OctetString + help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvRebuildingPhyDrv + oid: 1.3.6.1.4.1.232.3.2.3.1.1.17 + type: gauge + help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvMultipathAccess + oid: 1.3.6.1.4.1.232.3.2.3.1.1.18 + type: gauge + help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: notConfigured + 4: pathRedundant + 5: noRedundantPath + - name: cpqDaLogDrvNmbrOfParityGroups + oid: 1.3.6.1.4.1.232.3.2.3.1.1.19 + type: gauge + help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvSplitMirrorBackupLogDrv + oid: 1.3.6.1.4.1.232.3.2.3.1.1.20 + type: gauge + help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: isNotBackupLogicalDrive + 3: isBackupLogicalDrive + - name: cpqDaLogDrvCacheVolAccelAssocType + oid: 1.3.6.1.4.1.232.3.2.3.1.1.21 + type: gauge + help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: nonMember + 3: logicalDriveMember + 4: cacheVolumeMember + - name: cpqDaLogDrvCacheVolIndex + oid: 1.3.6.1.4.1.232.3.2.3.1.1.22 + type: gauge + help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvRPIPercentComplete + oid: 1.3.6.1.4.1.232.3.2.3.1.1.23 + type: gauge + help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + - name: cpqDaLogDrvSSDSmartPathStatus + oid: 1.3.6.1.4.1.232.3.2.3.1.1.24 + type: gauge + help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: updateDriver + 3: ssdSmartPathDisabled + 4: ssdSmartPathEnabled + - name: cpqDaLogDrvEncryptionStatus + oid: 1.3.6.1.4.1.232.3.2.3.1.1.25 + type: gauge + help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25 + indexes: + - labelname: cpqDaLogDrvCntlrIndex + type: gauge + - labelname: cpqDaLogDrvIndex + type: gauge + enum_values: + 1: other + 2: encrypted + 3: notEncrypted + - name: cpqDaPhyDrvCntlrIndex + oid: 1.3.6.1.4.1.232.3.2.5.1.1.1 + type: gauge + help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvIndex + oid: 1.3.6.1.4.1.232.3.2.5.1.1.2 + type: gauge + help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvModel + oid: 1.3.6.1.4.1.232.3.2.5.1.1.3 + type: DisplayString + help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvFWRev + oid: 1.3.6.1.4.1.232.3.2.5.1.1.4 + type: DisplayString + help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBay + oid: 1.3.6.1.4.1.232.3.2.5.1.1.5 + type: gauge + help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.6 + type: gauge + help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + 4: predictiveFailure + 5: erasing + 6: eraseDone + 7: eraseQueued + 8: ssdWearOut + 9: notAuthenticated + - name: cpqDaPhyDrvFactReallocs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.7 + type: gauge + help: This shows the number of spare sectors available for remapping at the time the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvUsedReallocs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.8 + type: counter + help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvRefHours + oid: 1.3.6.1.4.1.232.3.2.5.1.1.9 + type: counter + help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHReads + oid: 1.3.6.1.4.1.232.3.2.5.1.1.10 + type: counter + help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvReads + oid: 1.3.6.1.4.1.232.3.2.5.1.1.11 + type: counter + help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHWrites + oid: 1.3.6.1.4.1.232.3.2.5.1.1.12 + type: counter + help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvWrites + oid: 1.3.6.1.4.1.232.3.2.5.1.1.13 + type: counter + help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHSeeks + oid: 1.3.6.1.4.1.232.3.2.5.1.1.14 + type: counter + help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSeeks + oid: 1.3.6.1.4.1.232.3.2.5.1.1.15 + type: counter + help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHardReadErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.16 + type: counter + help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvRecvReadErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.17 + type: counter + help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHardWriteErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.18 + type: counter + help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvRecvWriteErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.19 + type: counter + help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHSeekErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.20 + type: counter + help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSeekErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.21 + type: counter + help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSpinupTime + oid: 1.3.6.1.4.1.232.3.2.5.1.1.22 + type: gauge + help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvFunctTest1 + oid: 1.3.6.1.4.1.232.3.2.5.1.1.23 + type: gauge + help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvFunctTest2 + oid: 1.3.6.1.4.1.232.3.2.5.1.1.24 + type: gauge + help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvFunctTest3 + oid: 1.3.6.1.4.1.232.3.2.5.1.1.25 + type: gauge + help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvDrqTimeouts + oid: 1.3.6.1.4.1.232.3.2.5.1.1.26 + type: counter + help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvOtherTimeouts + oid: 1.3.6.1.4.1.232.3.2.5.1.1.27 + type: counter + help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSpinupRetries + oid: 1.3.6.1.4.1.232.3.2.5.1.1.28 + type: counter + help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBadRecvReads + oid: 1.3.6.1.4.1.232.3.2.5.1.1.29 + type: counter + help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBadRecvWrites + oid: 1.3.6.1.4.1.232.3.2.5.1.1.30 + type: counter + help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvFormatErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.31 + type: counter + help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvPostErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.32 + type: counter + help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvNotReadyErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.33 + type: counter + help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvReallocAborts + oid: 1.3.6.1.4.1.232.3.2.5.1.1.34 + type: counter + help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvThreshPassed + oid: 1.3.6.1.4.1.232.3.2.5.1.1.35 + type: gauge + help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: "false" + 2: "true" + - name: cpqDaPhyDrvHasMonInfo + oid: 1.3.6.1.4.1.232.3.2.5.1.1.36 + type: gauge + help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: "false" + 2: "true" + - name: cpqDaPhyDrvCondition + oid: 1.3.6.1.4.1.232.3.2.5.1.1.37 + type: gauge + help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqDaPhyDrvHotPlugs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.38 + type: counter + help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvMediaErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.39 + type: counter + help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHardwareErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.40 + type: counter + help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvAbortedCmds + oid: 1.3.6.1.4.1.232.3.2.5.1.1.41 + type: counter + help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSpinUpErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.42 + type: counter + help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBadTargetErrs + oid: 1.3.6.1.4.1.232.3.2.5.1.1.43 + type: counter + help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvLocation + oid: 1.3.6.1.4.1.232.3.2.5.1.1.44 + type: gauge + help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: internal + 3: external + 4: proLiant + - name: cpqDaPhyDrvSize + oid: 1.3.6.1.4.1.232.3.2.5.1.1.45 + type: gauge + help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBusFaults + oid: 1.3.6.1.4.1.232.3.2.5.1.1.46 + type: counter + help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvIrqDeglitches + oid: 1.3.6.1.4.1.232.3.2.5.1.1.47 + type: counter + help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvHotPlug + oid: 1.3.6.1.4.1.232.3.2.5.1.1.48 + type: gauge + help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: hotPlug + 3: nonHotPlug + - name: cpqDaPhyDrvPlacement + oid: 1.3.6.1.4.1.232.3.2.5.1.1.49 + type: gauge + help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: internal + 3: external + - name: cpqDaPhyDrvBusNumber + oid: 1.3.6.1.4.1.232.3.2.5.1.1.50 + type: gauge + help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSerialNum + oid: 1.3.6.1.4.1.232.3.2.5.1.1.51 + type: DisplayString + help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvPreFailMonitoring + oid: 1.3.6.1.4.1.232.3.2.5.1.1.52 + type: gauge + help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: notAvailable + 3: available + - name: cpqDaPhyDrvCurrentWidth + oid: 1.3.6.1.4.1.232.3.2.5.1.1.53 + type: gauge + help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: narrow + 3: wide16 + - name: cpqDaPhyDrvCurrentSpeed + oid: 1.3.6.1.4.1.232.3.2.5.1.1.54 + type: gauge + help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: asynchronous + 3: fast + 4: ultra + 5: ultra2 + 6: ultra3 + 7: ultra320 + - name: cpqDaPhyDrvFailureCode + oid: 1.3.6.1.4.1.232.3.2.5.1.1.55 + type: gauge + help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBlinkTime + oid: 1.3.6.1.4.1.232.3.2.5.1.1.56 + type: counter + help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSmartStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.57 + type: gauge + help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: replaceDrive + 4: replaceDriveSSDWearOut + - name: cpqDaPhyDrvConfigurationStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.58 + type: gauge + help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: configured + 3: notConfigured + - name: cpqDaPhyDrvRotationalSpeed + oid: 1.3.6.1.4.1.232.3.2.5.1.1.59 + type: gauge + help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rpm7200 + 3: rpm10K + 4: rpm15K + 5: rpmSsd + - name: cpqDaPhyDrvType + oid: 1.3.6.1.4.1.232.3.2.5.1.1.60 + type: gauge + help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: parallelScsi + 3: sata + 4: sas + 5: nvme + - name: cpqDaPhyDrvSataVersion + oid: 1.3.6.1.4.1.232.3.2.5.1.1.61 + type: gauge + help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: sataOne + 3: sataTwo + - name: cpqDaPhyDrvHostConnector + oid: 1.3.6.1.4.1.232.3.2.5.1.1.62 + type: DisplayString + help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvBoxOnConnector + oid: 1.3.6.1.4.1.232.3.2.5.1.1.63 + type: gauge + help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvLocationString + oid: 1.3.6.1.4.1.232.3.2.5.1.1.64 + type: DisplayString + help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvNegotiatedLinkRate + oid: 1.3.6.1.4.1.232.3.2.5.1.1.65 + type: gauge + help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rate-1-5 + 3: rate-3-0 + 4: rate-6-0 + 5: rate-12-0 + - name: cpqDaPhyDrvNcqSupport + oid: 1.3.6.1.4.1.232.3.2.5.1.1.66 + type: gauge + help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: noControllerSupport + 3: noDriveSupport + 4: ncqDisabled + 5: ncqEnabled + - name: cpqDaPhyDrvPhyCount + oid: 1.3.6.1.4.1.232.3.2.5.1.1.67 + type: gauge + help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvMultipathAccess + oid: 1.3.6.1.4.1.232.3.2.5.1.1.68 + type: gauge + help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: notConfigured + 4: pathRedundant + 5: noRedundantPath + 6: driveFailed + - name: cpqDaPhyDrvMediaType + oid: 1.3.6.1.4.1.232.3.2.5.1.1.69 + type: gauge + help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rotatingPlatters + 3: solidState + 4: smr + - name: cpqDaPhyDrvCurrentTemperature + oid: 1.3.6.1.4.1.232.3.2.5.1.1.70 + type: gauge + help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvTemperatureThreshold + oid: 1.3.6.1.4.1.232.3.2.5.1.1.71 + type: gauge + help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvMaximumTemperature + oid: 1.3.6.1.4.1.232.3.2.5.1.1.72 + type: gauge + help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSSDWearStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.73 + type: gauge + help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: fiftySixDayThreshold + 4: fivePercentThreshold + 5: twoPercentThreshold + 6: ssdWearOut + - name: cpqDaPhyDrvPowerOnHours + oid: 1.3.6.1.4.1.232.3.2.5.1.1.74 + type: counter + help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSSDPercntEndrnceUsed + oid: 1.3.6.1.4.1.232.3.2.5.1.1.75 + type: gauge + help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSSDEstTimeRemainingHours + oid: 1.3.6.1.4.1.232.3.2.5.1.1.76 + type: counter + help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.3.2.5.1.1.76 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvAuthenticationStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.77 + type: gauge + help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: authenticationFailed + 4: authenticationPassed + - name: cpqDaPhyDrvSmartCarrierAppFWRev + oid: 1.3.6.1.4.1.232.3.2.5.1.1.78 + type: gauge + help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvSmartCarrierBootldrFWRev + oid: 1.3.6.1.4.1.232.3.2.5.1.1.79 + type: gauge + help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + - name: cpqDaPhyDrvEncryptionStatus + oid: 1.3.6.1.4.1.232.3.2.5.1.1.80 + type: gauge + help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80 + indexes: + - labelname: cpqDaPhyDrvCntlrIndex + type: gauge + - labelname: cpqDaPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: encrypted + 3: notEncrypted + - name: cpqScsiMibRevMajor + oid: 1.3.6.1.4.1.232.5.1.1 + type: gauge + help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1 + - name: cpqScsiMibRevMinor + oid: 1.3.6.1.4.1.232.5.1.2 + type: gauge + help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2 + - name: cpqScsiMibCondition + oid: 1.3.6.1.4.1.232.5.1.3 + type: gauge + help: The overall condition - 1.3.6.1.4.1.232.5.1.3 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqScsiNw3xDriverName + oid: 1.3.6.1.4.1.232.5.2.1.1.1 + type: DisplayString + help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1 + - name: cpqScsiNw3xDriverVers + oid: 1.3.6.1.4.1.232.5.2.1.1.2 + type: DisplayString + help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2 + - name: cpqScsiNw3xDriverPollType + oid: 1.3.6.1.4.1.232.5.2.1.1.3 + type: gauge + help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3 + enum_values: + 1: other + 2: polled + 3: demand + - name: cpqScsiNw3xDriverPollTime + oid: 1.3.6.1.4.1.232.5.2.1.1.4 + type: gauge + help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4 + - name: cpqScsiNw3xCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1 + type: gauge + help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xBusIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2 + type: gauge + help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xXptDesc + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3 + type: DisplayString + help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xXptVers + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4 + type: DisplayString + help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xSimDesc + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5 + type: DisplayString + help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xSimVers + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6 + type: DisplayString + help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xHbaDesc + oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7 + type: DisplayString + help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7 + indexes: + - labelname: cpqScsiNw3xCntlrIndex + type: gauge + - labelname: cpqScsiNw3xBusIndex + type: gauge + - name: cpqScsiNw3xStatCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1 + type: gauge + help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xStatBusIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2 + type: gauge + help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xStatLogDrvIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3 + type: gauge + help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xTotalReads + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4 + type: counter + help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xTotalWrites + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5 + type: counter + help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xCorrReads + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6 + type: counter + help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xCorrWrites + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7 + type: counter + help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xFatalReads + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8 + type: counter + help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xFatalWrites + oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9 + type: counter + help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9 + indexes: + - labelname: cpqScsiNw3xStatCntlrIndex + type: gauge + - labelname: cpqScsiNw3xStatBusIndex + type: gauge + - labelname: cpqScsiNw3xStatLogDrvIndex + type: gauge + - name: cpqScsiNw3xVolCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1 + type: gauge + help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1 + indexes: + - labelname: cpqScsiNw3xVolCntlrIndex + type: gauge + - labelname: cpqScsiNw3xVolBusIndex + type: gauge + - labelname: cpqScsiNw3xVolLogDrvIndex + type: gauge + - name: cpqScsiNw3xVolBusIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2 + type: gauge + help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2 + indexes: + - labelname: cpqScsiNw3xVolCntlrIndex + type: gauge + - labelname: cpqScsiNw3xVolBusIndex + type: gauge + - labelname: cpqScsiNw3xVolLogDrvIndex + type: gauge + - name: cpqScsiNw3xVolLogDrvIndex + oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3 + type: gauge + help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3 + indexes: + - labelname: cpqScsiNw3xVolCntlrIndex + type: gauge + - labelname: cpqScsiNw3xVolBusIndex + type: gauge + - labelname: cpqScsiNw3xVolLogDrvIndex + type: gauge + - name: cpqScsiNw3xVolMap + oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4 + type: OctetString + help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4 + indexes: + - labelname: cpqScsiNw3xVolCntlrIndex + type: gauge + - labelname: cpqScsiNw3xVolBusIndex + type: gauge + - labelname: cpqScsiNw3xVolLogDrvIndex + type: gauge + - name: cpqScsiOsCommonPollFreq + oid: 1.3.6.1.4.1.232.5.2.1.4.1 + type: gauge + help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1 + - name: cpqScsiOsCommonModuleIndex + oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1 + type: gauge + help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1 + indexes: + - labelname: cpqScsiOsCommonModuleIndex + type: gauge + - name: cpqScsiOsCommonModuleName + oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2 + type: DisplayString + help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2 + indexes: + - labelname: cpqScsiOsCommonModuleIndex + type: gauge + - name: cpqScsiOsCommonModuleVersion + oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3 + type: DisplayString + help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3 + indexes: + - labelname: cpqScsiOsCommonModuleIndex + type: gauge + - name: cpqScsiOsCommonModuleDate + oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4 + type: OctetString + help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4 + indexes: + - labelname: cpqScsiOsCommonModuleIndex + type: gauge + - name: cpqScsiOsCommonModulePurpose + oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5 + type: DisplayString + help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5 + indexes: + - labelname: cpqScsiOsCommonModuleIndex + type: gauge + - name: cpqScsiCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.2.1.1.1 + type: gauge + help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrBusIndex + oid: 1.3.6.1.4.1.232.5.2.2.1.1.2 + type: gauge + help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrModel + oid: 1.3.6.1.4.1.232.5.2.2.1.1.3 + type: gauge + help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + enum_values: + 1: other + 2: cpqs710 + 3: cpqs94 + 4: cpqs810p + 5: cpqs825e + 6: cpqs825p + 7: cpqs974p + 8: cpqs875p + 9: extended + 10: cpqs895p + 11: cpqs896p + 12: cpqa789x + 13: cpqs876t + 14: hpu320 + 15: hpu320r + 16: generic + 17: hp1u320g2 + 18: hp1u320g1 + 19: hpSc11Xe + - name: cpqScsiCntlrFWVers + oid: 1.3.6.1.4.1.232.5.2.2.1.1.4 + type: DisplayString + help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrSWVers + oid: 1.3.6.1.4.1.232.5.2.2.1.1.5 + type: DisplayString + help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrSlot + oid: 1.3.6.1.4.1.232.5.2.2.1.1.6 + type: gauge + help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrStatus + oid: 1.3.6.1.4.1.232.5.2.2.1.1.7 + type: gauge + help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + - name: cpqScsiCntlrHardResets + oid: 1.3.6.1.4.1.232.5.2.2.1.1.8 + type: counter + help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrSoftResets + oid: 1.3.6.1.4.1.232.5.2.2.1.1.9 + type: counter + help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrTimeouts + oid: 1.3.6.1.4.1.232.5.2.2.1.1.10 + type: counter + help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrBaseIOAddr + oid: 1.3.6.1.4.1.232.5.2.2.1.1.11 + type: gauge + help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrCondition + oid: 1.3.6.1.4.1.232.5.2.2.1.1.12 + type: gauge + help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqScsiCntlrSerialNum + oid: 1.3.6.1.4.1.232.5.2.2.1.1.13 + type: DisplayString + help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrBusWidth + oid: 1.3.6.1.4.1.232.5.2.2.1.1.14 + type: gauge + help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + enum_values: + 1: other + 2: narrow + 3: wide16 + - name: cpqScsiCntlrModelExtended + oid: 1.3.6.1.4.1.232.5.2.2.1.1.15 + type: DisplayString + help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrHwLocation + oid: 1.3.6.1.4.1.232.5.2.2.1.1.16 + type: DisplayString + help: A text description of the hardware location, on complex multi SBB hardware only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiCntlrPciLocation + oid: 1.3.6.1.4.1.232.5.2.2.1.1.17 + type: DisplayString + help: A string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI bus number, DD is the PCI device number, and F is the PCI function number - 1.3.6.1.4.1.232.5.2.2.1.1.17 + indexes: + - labelname: cpqScsiCntlrIndex + type: gauge + - labelname: cpqScsiCntlrBusIndex + type: gauge + - name: cpqScsiLogDrvCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.3.1.1.1 + type: gauge + help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvBusIndex + oid: 1.3.6.1.4.1.232.5.2.3.1.1.2 + type: gauge + help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvIndex + oid: 1.3.6.1.4.1.232.5.2.3.1.1.3 + type: gauge + help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvFaultTol + oid: 1.3.6.1.4.1.232.5.2.3.1.1.4 + type: gauge + help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + enum_values: + 1: other + 2: none + 3: mirroring + 4: dataGuard + 5: distribDataGuard + 6: enhancedMirroring + - name: cpqScsiLogDrvStatus + oid: 1.3.6.1.4.1.232.5.2.3.1.1.5 + type: gauge + help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + 4: unconfigured + 5: recovering + 6: readyForRebuild + 7: rebuilding + 8: wrongDrive + 9: badConnect + 10: degraded + 11: disabled + - name: cpqScsiLogDrvSize + oid: 1.3.6.1.4.1.232.5.2.3.1.1.6 + type: gauge + help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvPhyDrvIDs + oid: 1.3.6.1.4.1.232.5.2.3.1.1.7 + type: OctetString + help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvCondition + oid: 1.3.6.1.4.1.232.5.2.3.1.1.8 + type: gauge + help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqScsiLogDrvStripeSize + oid: 1.3.6.1.4.1.232.5.2.3.1.1.9 + type: gauge + help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvAvailSpares + oid: 1.3.6.1.4.1.232.5.2.3.1.1.10 + type: OctetString + help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvPercentRebuild + oid: 1.3.6.1.4.1.232.5.2.3.1.1.11 + type: gauge + help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiLogDrvOsName + oid: 1.3.6.1.4.1.232.5.2.3.1.1.12 + type: DisplayString + help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12 + indexes: + - labelname: cpqScsiLogDrvCntlrIndex + type: gauge + - labelname: cpqScsiLogDrvBusIndex + type: gauge + - labelname: cpqScsiLogDrvIndex + type: gauge + - name: cpqScsiPhyDrvCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.4.1.1.1 + type: gauge + help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvBusIndex + oid: 1.3.6.1.4.1.232.5.2.4.1.1.2 + type: gauge + help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvIndex + oid: 1.3.6.1.4.1.232.5.2.4.1.1.3 + type: gauge + help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvModel + oid: 1.3.6.1.4.1.232.5.2.4.1.1.4 + type: DisplayString + help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvFWRev + oid: 1.3.6.1.4.1.232.5.2.4.1.1.5 + type: DisplayString + help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvVendor + oid: 1.3.6.1.4.1.232.5.2.4.1.1.6 + type: DisplayString + help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvSize + oid: 1.3.6.1.4.1.232.5.2.4.1.1.7 + type: gauge + help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvScsiID + oid: 1.3.6.1.4.1.232.5.2.4.1.1.8 + type: gauge + help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvStatus + oid: 1.3.6.1.4.1.232.5.2.4.1.1.9 + type: gauge + help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + 4: notConfigured + 5: badCable + 6: missingWasOk + 7: missingWasFailed + 8: predictiveFailure + 9: missingWasPredictiveFailure + 10: offline + 11: missingWasOffline + 12: hardError + - name: cpqScsiPhyDrvServiceHours + oid: 1.3.6.1.4.1.232.5.2.4.1.1.10 + type: counter + help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvHighReadSectors + oid: 1.3.6.1.4.1.232.5.2.4.1.1.11 + type: counter + help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvLowReadSectors + oid: 1.3.6.1.4.1.232.5.2.4.1.1.12 + type: counter + help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvHighWriteSectors + oid: 1.3.6.1.4.1.232.5.2.4.1.1.13 + type: counter + help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvLowWriteSectors + oid: 1.3.6.1.4.1.232.5.2.4.1.1.14 + type: counter + help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvHardReadErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.15 + type: counter + help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvHardWriteErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.16 + type: counter + help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvEccCorrReads + oid: 1.3.6.1.4.1.232.5.2.4.1.1.17 + type: counter + help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvRecvReadErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.18 + type: counter + help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvRecvWriteErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.19 + type: counter + help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvSeekErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.20 + type: counter + help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvSpinupTime + oid: 1.3.6.1.4.1.232.5.2.4.1.1.21 + type: gauge + help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvUsedReallocs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.22 + type: counter + help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvTimeouts + oid: 1.3.6.1.4.1.232.5.2.4.1.1.23 + type: counter + help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvPostErrs + oid: 1.3.6.1.4.1.232.5.2.4.1.1.24 + type: counter + help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvPostErrCode + oid: 1.3.6.1.4.1.232.5.2.4.1.1.25 + type: gauge + help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvCondition + oid: 1.3.6.1.4.1.232.5.2.4.1.1.26 + type: gauge + help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqScsiPhyDrvFuncTest1 + oid: 1.3.6.1.4.1.232.5.2.4.1.1.27 + type: gauge + help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvFuncTest2 + oid: 1.3.6.1.4.1.232.5.2.4.1.1.28 + type: gauge + help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvStatsPreserved + oid: 1.3.6.1.4.1.232.5.2.4.1.1.29 + type: gauge + help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: inNVRAM + 3: onDisk + 4: noCPUSupport + 5: noFreeNVRAM + 6: noDrvSupport + 7: noSoftwareSupport + 8: statsNotSupported + - name: cpqScsiPhyDrvSerialNum + oid: 1.3.6.1.4.1.232.5.2.4.1.1.30 + type: DisplayString + help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvLocation + oid: 1.3.6.1.4.1.232.5.2.4.1.1.31 + type: gauge + help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: proliant + - name: cpqScsiPhyDrvParent + oid: 1.3.6.1.4.1.232.5.2.4.1.1.32 + type: gauge + help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvSectorSize + oid: 1.3.6.1.4.1.232.5.2.4.1.1.33 + type: gauge + help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvHotPlug + oid: 1.3.6.1.4.1.232.5.2.4.1.1.34 + type: gauge + help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: hotPlug + 3: nonHotPlug + - name: cpqScsiPhyDrvPlacement + oid: 1.3.6.1.4.1.232.5.2.4.1.1.35 + type: gauge + help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: internal + 3: external + - name: cpqScsiPhyDrvPreFailMonitoring + oid: 1.3.6.1.4.1.232.5.2.4.1.1.36 + type: gauge + help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: notAvailable + 3: available + - name: cpqScsiPhyDrvOsName + oid: 1.3.6.1.4.1.232.5.2.4.1.1.37 + type: DisplayString + help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + - name: cpqScsiPhyDrvRotationalSpeed + oid: 1.3.6.1.4.1.232.5.2.4.1.1.38 + type: gauge + help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rpm7200 + 3: rpm10K + 4: rpm15K + - name: cpqScsiPhyDrvMemberLogDrv + oid: 1.3.6.1.4.1.232.5.2.4.1.1.39 + type: gauge + help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39 + indexes: + - labelname: cpqScsiPhyDrvCntlrIndex + type: gauge + - labelname: cpqScsiPhyDrvBusIndex + type: gauge + - labelname: cpqScsiPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: member + 3: spare + 4: nonMember + - name: cpqScsiTargetCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.5.1.1.1 + type: gauge + help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetBusIndex + oid: 1.3.6.1.4.1.232.5.2.5.1.1.2 + type: gauge + help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetScsiIdIndex + oid: 1.3.6.1.4.1.232.5.2.5.1.1.3 + type: gauge + help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetType + oid: 1.3.6.1.4.1.232.5.2.5.1.1.4 + type: gauge + help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + enum_values: + 1: other + 2: disk + 3: tape + 4: printer + 5: processor + 6: wormDrive + 7: cd-rom + 8: scanner + 9: optical + 10: jukeBox + 11: commDev + - name: cpqScsiTargetModel + oid: 1.3.6.1.4.1.232.5.2.5.1.1.5 + type: DisplayString + help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetFWRev + oid: 1.3.6.1.4.1.232.5.2.5.1.1.6 + type: DisplayString + help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetVendor + oid: 1.3.6.1.4.1.232.5.2.5.1.1.7 + type: DisplayString + help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetParityErrs + oid: 1.3.6.1.4.1.232.5.2.5.1.1.8 + type: counter + help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetPhaseErrs + oid: 1.3.6.1.4.1.232.5.2.5.1.1.9 + type: counter + help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetSelectTimeouts + oid: 1.3.6.1.4.1.232.5.2.5.1.1.10 + type: counter + help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetMsgRejects + oid: 1.3.6.1.4.1.232.5.2.5.1.1.11 + type: counter + help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetNegPeriod + oid: 1.3.6.1.4.1.232.5.2.5.1.1.12 + type: gauge + help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetLocation + oid: 1.3.6.1.4.1.232.5.2.5.1.1.13 + type: gauge + help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + enum_values: + 1: other + 2: proliant + - name: cpqScsiTargetNegSpeed + oid: 1.3.6.1.4.1.232.5.2.5.1.1.14 + type: gauge + help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetPhysWidth + oid: 1.3.6.1.4.1.232.5.2.5.1.1.15 + type: gauge + help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + enum_values: + 1: other + 2: narrow + 3: wide16 + - name: cpqScsiTargetNegWidth + oid: 1.3.6.1.4.1.232.5.2.5.1.1.16 + type: gauge + help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + - name: cpqScsiTargetTypeExtended + oid: 1.3.6.1.4.1.232.5.2.5.1.1.17 + type: gauge + help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + enum_values: + 1: other + 2: pdcd + 3: removableDisk + 4: dltAutoloader + 5: cdJukebox + 6: cr3500 + 7: autoloader + - name: cpqScsiTargetCurrentSpeed + oid: 1.3.6.1.4.1.232.5.2.5.1.1.18 + type: gauge + help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18 + indexes: + - labelname: cpqScsiTargetCntlrIndex + type: gauge + - labelname: cpqScsiTargetBusIndex + type: gauge + - labelname: cpqScsiTargetScsiIdIndex + type: gauge + enum_values: + 1: other + 2: asynchronous + 3: fast + 4: ultra + 5: ultra2 + 6: ultra3 + 7: scsi1 + 8: ultra4 + - name: cpqScsiCdDrvCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.6.1.1.1 + type: gauge + help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvBusIndex + oid: 1.3.6.1.4.1.232.5.2.6.1.1.2 + type: gauge + help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvScsiIdIndex + oid: 1.3.6.1.4.1.232.5.2.6.1.1.3 + type: gauge + help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvLunIndex + oid: 1.3.6.1.4.1.232.5.2.6.1.1.4 + type: gauge + help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvModel + oid: 1.3.6.1.4.1.232.5.2.6.1.1.5 + type: DisplayString + help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvVendor + oid: 1.3.6.1.4.1.232.5.2.6.1.1.6 + type: DisplayString + help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqScsiCdDrvFwRev + oid: 1.3.6.1.4.1.232.5.2.6.1.1.7 + type: DisplayString + help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7 + indexes: + - labelname: cpqScsiCdDrvCntlrIndex + type: gauge + - labelname: cpqScsiCdDrvBusIndex + type: gauge + - labelname: cpqScsiCdDrvScsiIdIndex + type: gauge + - labelname: cpqScsiCdDrvLunIndex + type: gauge + - name: cpqCdLibraryCntlrIndex + oid: 1.3.6.1.4.1.232.5.2.6.2.1.1 + type: gauge + help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryBusIndex + oid: 1.3.6.1.4.1.232.5.2.6.2.1.2 + type: gauge + help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryScsiIdIndex + oid: 1.3.6.1.4.1.232.5.2.6.2.1.3 + type: gauge + help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryLunIndex + oid: 1.3.6.1.4.1.232.5.2.6.2.1.4 + type: gauge + help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryCondition + oid: 1.3.6.1.4.1.232.5.2.6.2.1.5 + type: gauge + help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqCdLibraryStatus + oid: 1.3.6.1.4.1.232.5.2.6.2.1.6 + type: gauge + help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + 4: offline + - name: cpqCdLibraryModel + oid: 1.3.6.1.4.1.232.5.2.6.2.1.7 + type: DisplayString + help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryVendor + oid: 1.3.6.1.4.1.232.5.2.6.2.1.8 + type: DisplayString + help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibrarySerialNumber + oid: 1.3.6.1.4.1.232.5.2.6.2.1.9 + type: DisplayString + help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryDriveList + oid: 1.3.6.1.4.1.232.5.2.6.2.1.10 + type: OctetString + help: CD Library Drive List This is a data structure containing the list of CD drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryFwRev + oid: 1.3.6.1.4.1.232.5.2.6.2.1.11 + type: DisplayString + help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqCdLibraryFwSubtype + oid: 1.3.6.1.4.1.232.5.2.6.2.1.12 + type: gauge + help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12 + indexes: + - labelname: cpqCdLibraryCntlrIndex + type: gauge + - labelname: cpqCdLibraryBusIndex + type: gauge + - labelname: cpqCdLibraryScsiIdIndex + type: gauge + - labelname: cpqCdLibraryLunIndex + type: gauge + - name: cpqScsiTrapPkts + oid: 1.3.6.1.4.1.232.5.3.1 + type: counter + help: The total number of trap packets issued by the SCSI enterprise since the instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1 + - name: cpqScsiTrapLogMaxSize + oid: 1.3.6.1.4.1.232.5.3.2 + type: gauge + help: The maximum number of entries that will currently be kept in the trap log - 1.3.6.1.4.1.232.5.3.2 + - name: cpqScsiTrapLogIndex + oid: 1.3.6.1.4.1.232.5.3.3.1.1 + type: gauge + help: The value of this object uniquely identifies this trapLogEntry at this time - 1.3.6.1.4.1.232.5.3.3.1.1 + indexes: + - labelname: cpqScsiTrapLogIndex + type: gauge + - name: cpqScsiTrapType + oid: 1.3.6.1.4.1.232.5.3.3.1.2 + type: gauge + help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2 + indexes: + - labelname: cpqScsiTrapLogIndex + type: gauge + enum_values: + 1: cpqScsiCntlrStatusChange + 2: cpqScsiLogDrvStatusChange + 3: cpqScsiPhyDrvStatusChange + 5001: cpqScsi2CntlrStatusChange + 5002: cpqScsi2LogDrvStatusChange + 5003: cpqScsi2PhyDrvStatusChange + - name: cpqScsiTrapTime + oid: 1.3.6.1.4.1.232.5.3.3.1.3 + type: OctetString + help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3 + indexes: + - labelname: cpqScsiTrapLogIndex + type: gauge + - name: cpqTapePhyDrvCntlrIndex + oid: 1.3.6.1.4.1.232.5.4.1.1.1.1 + type: gauge + help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvBusIndex + oid: 1.3.6.1.4.1.232.5.4.1.1.1.2 + type: gauge + help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvScsiIdIndex + oid: 1.3.6.1.4.1.232.5.4.1.1.1.3 + type: gauge + help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvLunIndex + oid: 1.3.6.1.4.1.232.5.4.1.1.1.4 + type: gauge + help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvType + oid: 1.3.6.1.4.1.232.5.4.1.1.1.5 + type: gauge + help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: cpqDat4-16 + 3: cpqDatAuto + 4: cpqDat2-8 + 5: cpqDlt10-20 + 6: cpqDlt20-40 + 7: cpqDlt15-30 + 8: cpqDlt35-70 + 9: cpqDat4-8 + 10: cpqSlr4-8 + 11: cpqDat12-24 + 12: cpqDatAuto12-24 + 13: cpqMlr16-32 + 14: cpqAit35 + 15: cpqAit50 + 16: cpqDat20-40 + 17: cpqDlt40-80 + 18: cpqDatAuto20-40 + 19: cpqSuperDlt1 + 20: cpqAit35Lvd + 21: cpqCompaq + - name: cpqTapePhyDrvCondition + oid: 1.3.6.1.4.1.232.5.4.1.1.1.6 + type: gauge + help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqTapePhyDrvMagSize + oid: 1.3.6.1.4.1.232.5.4.1.1.1.7 + type: gauge + help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvSerialNumber + oid: 1.3.6.1.4.1.232.5.4.1.1.1.8 + type: DisplayString + help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvCleanReq + oid: 1.3.6.1.4.1.232.5.4.1.1.1.9 + type: gauge + help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqTapePhyDrvCleanTapeRepl + oid: 1.3.6.1.4.1.232.5.4.1.1.1.10 + type: gauge + help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqTapePhyDrvFwSubtype + oid: 1.3.6.1.4.1.232.5.4.1.1.1.11 + type: gauge + help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvName + oid: 1.3.6.1.4.1.232.5.4.1.1.1.12 + type: DisplayString + help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvCleanTapeCount + oid: 1.3.6.1.4.1.232.5.4.1.1.1.13 + type: gauge + help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvFwRev + oid: 1.3.6.1.4.1.232.5.4.1.1.1.14 + type: DisplayString + help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvStatus + oid: 1.3.6.1.4.1.232.5.4.1.1.1.15 + type: gauge + help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 4: failed + 5: offline + 6: missingWasOk + 7: missingWasFailed + 8: missingWasOffline + - name: cpqTapePhyDrvHotPlug + oid: 1.3.6.1.4.1.232.5.4.1.1.1.16 + type: gauge + help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: hotPlug + 3: nonHotPlug + - name: cpqTapePhyDrvPlacement + oid: 1.3.6.1.4.1.232.5.4.1.1.1.17 + type: gauge + help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: internal + 3: external + - name: cpqTapePhyDrvLibraryDrive + oid: 1.3.6.1.4.1.232.5.4.1.1.1.18 + type: gauge + help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + enum_values: + 1: other + 2: "true" + 3: "false" + - name: cpqTapePhyDrvLoaderName + oid: 1.3.6.1.4.1.232.5.4.1.1.1.19 + type: DisplayString + help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvLoaderFwRev + oid: 1.3.6.1.4.1.232.5.4.1.1.1.20 + type: DisplayString + help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapePhyDrvLoaderSerialNum + oid: 1.3.6.1.4.1.232.5.4.1.1.1.21 + type: DisplayString + help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21 + indexes: + - labelname: cpqTapePhyDrvCntlrIndex + type: gauge + - labelname: cpqTapePhyDrvBusIndex + type: gauge + - labelname: cpqTapePhyDrvScsiIdIndex + type: gauge + - labelname: cpqTapePhyDrvLunIndex + type: gauge + - name: cpqTapeCountersCntlrIndex + oid: 1.3.6.1.4.1.232.5.4.2.1.1.1 + type: gauge + help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersBusIndex + oid: 1.3.6.1.4.1.232.5.4.2.1.1.2 + type: gauge + help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersScsiIdIndex + oid: 1.3.6.1.4.1.232.5.4.2.1.1.3 + type: gauge + help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersLunIndex + oid: 1.3.6.1.4.1.232.5.4.2.1.1.4 + type: gauge + help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersReWrites + oid: 1.3.6.1.4.1.232.5.4.2.1.1.5 + type: counter + help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersReReads + oid: 1.3.6.1.4.1.232.5.4.2.1.1.6 + type: counter + help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersTotalErrors + oid: 1.3.6.1.4.1.232.5.4.2.1.1.7 + type: counter + help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersTotalUncorrectable + oid: 1.3.6.1.4.1.232.5.4.2.1.1.8 + type: counter + help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeCountersTotalBytes + oid: 1.3.6.1.4.1.232.5.4.2.1.1.9 + type: counter + help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9 + indexes: + - labelname: cpqTapeCountersCntlrIndex + type: gauge + - labelname: cpqTapeCountersBusIndex + type: gauge + - labelname: cpqTapeCountersScsiIdIndex + type: gauge + - labelname: cpqTapeCountersLunIndex + type: gauge + - name: cpqTapeLibraryCntlrIndex + oid: 1.3.6.1.4.1.232.5.4.3.1.1.1 + type: gauge + help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryBusIndex + oid: 1.3.6.1.4.1.232.5.4.3.1.1.2 + type: gauge + help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryScsiIdIndex + oid: 1.3.6.1.4.1.232.5.4.3.1.1.3 + type: gauge + help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryLunIndex + oid: 1.3.6.1.4.1.232.5.4.3.1.1.4 + type: gauge + help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryCondition + oid: 1.3.6.1.4.1.232.5.4.3.1.1.5 + type: gauge + help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqTapeLibraryStatus + oid: 1.3.6.1.4.1.232.5.4.3.1.1.6 + type: gauge + help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryDoorStatus + oid: 1.3.6.1.4.1.232.5.4.3.1.1.7 + type: gauge + help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: closed + 3: open + 4: notSupported + - name: cpqTapeLibraryStatHours + oid: 1.3.6.1.4.1.232.5.4.3.1.1.8 + type: counter + help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryStatMoves + oid: 1.3.6.1.4.1.232.5.4.3.1.1.9 + type: counter + help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryName + oid: 1.3.6.1.4.1.232.5.4.3.1.1.10 + type: DisplayString + help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibrarySerialNumber + oid: 1.3.6.1.4.1.232.5.4.3.1.1.11 + type: DisplayString + help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryDriveList + oid: 1.3.6.1.4.1.232.5.4.3.1.1.12 + type: OctetString + help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryState + oid: 1.3.6.1.4.1.232.5.4.3.1.1.13 + type: gauge + help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + 5: offline + - name: cpqTapeLibraryTemperature + oid: 1.3.6.1.4.1.232.5.4.3.1.1.14 + type: gauge + help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: ok + 4: safeTempExceeded + 5: maxTempExceeded + - name: cpqTapeLibraryRedundancy + oid: 1.3.6.1.4.1.232.5.4.3.1.1.15 + type: gauge + help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: capable + 4: notCapable + 5: active + - name: cpqTapeLibraryHotSwap + oid: 1.3.6.1.4.1.232.5.4.3.1.1.16 + type: gauge + help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: capable + 4: notCapable + - name: cpqTapeLibraryFwRev + oid: 1.3.6.1.4.1.232.5.4.3.1.1.17 + type: DisplayString + help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqTapeLibraryTapeList + oid: 1.3.6.1.4.1.232.5.4.3.1.1.18 + type: OctetString + help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18 + indexes: + - labelname: cpqTapeLibraryCntlrIndex + type: gauge + - labelname: cpqTapeLibraryBusIndex + type: gauge + - labelname: cpqTapeLibraryScsiIdIndex + type: gauge + - labelname: cpqTapeLibraryLunIndex + type: gauge + - name: cpqSasHbaIndex + oid: 1.3.6.1.4.1.232.5.5.1.1.1.1 + type: gauge + help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasHbaHwLocation + oid: 1.3.6.1.4.1.232.5.5.1.1.1.2 + type: DisplayString + help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasHbaModel + oid: 1.3.6.1.4.1.232.5.5.1.1.1.3 + type: gauge + help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + enum_values: + 1: other + 2: generic + 3: sas8int + 4: sas4int + 5: sasSc44Ge + 6: sasSc40Ge + 7: sasSc08Ge + 8: sasSc08e + 9: sasH220i + 10: sasH221 + 11: sasH210i + 12: sasH220 + 13: sasH222 + 14: sasP824ip + - name: cpqSasHbaStatus + oid: 1.3.6.1.4.1.232.5.5.1.1.1.4 + type: gauge + help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: failed + - name: cpqSasHbaCondition + oid: 1.3.6.1.4.1.232.5.5.1.1.1.5 + type: gauge + help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqSasHbaOverallCondition + oid: 1.3.6.1.4.1.232.5.5.1.1.1.6 + type: gauge + help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqSasHbaSerialNumber + oid: 1.3.6.1.4.1.232.5.5.1.1.1.7 + type: DisplayString + help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasHbaFwVersion + oid: 1.3.6.1.4.1.232.5.5.1.1.1.8 + type: DisplayString + help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasHbaBiosVersion + oid: 1.3.6.1.4.1.232.5.5.1.1.1.9 + type: DisplayString + help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasHbaPciLocation + oid: 1.3.6.1.4.1.232.5.5.1.1.1.10 + type: DisplayString + help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10 + indexes: + - labelname: cpqSasHbaIndex + type: gauge + - name: cpqSasPhyDrvHbaIndex + oid: 1.3.6.1.4.1.232.5.5.2.1.1.1 + type: gauge + help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvIndex + oid: 1.3.6.1.4.1.232.5.5.2.1.1.2 + type: gauge + help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvLocationString + oid: 1.3.6.1.4.1.232.5.5.2.1.1.3 + type: DisplayString + help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvModel + oid: 1.3.6.1.4.1.232.5.5.2.1.1.4 + type: DisplayString + help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvStatus + oid: 1.3.6.1.4.1.232.5.5.2.1.1.5 + type: gauge + help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: predictiveFailure + 4: offline + 5: failed + 6: missingWasOk + 7: missingWasPredictiveFailure + 8: missingWasOffline + 9: missingWasFailed + 10: ssdWearOut + 11: missingWasSSDWearOut + 12: notAuthenticated + 13: missingWasNotAuthenticated + - name: cpqSasPhyDrvCondition + oid: 1.3.6.1.4.1.232.5.5.2.1.1.6 + type: gauge + help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqSasPhyDrvFWRev + oid: 1.3.6.1.4.1.232.5.5.2.1.1.7 + type: DisplayString + help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSize + oid: 1.3.6.1.4.1.232.5.5.2.1.1.8 + type: gauge + help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvUsedReallocs + oid: 1.3.6.1.4.1.232.5.5.2.1.1.9 + type: counter + help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSerialNumber + oid: 1.3.6.1.4.1.232.5.5.2.1.1.10 + type: DisplayString + help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvMemberLogDrv + oid: 1.3.6.1.4.1.232.5.5.2.1.1.11 + type: gauge + help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: member + 3: spare + 4: nonMember + - name: cpqSasPhyDrvRotationalSpeed + oid: 1.3.6.1.4.1.232.5.5.2.1.1.12 + type: gauge + help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rpm7200 + 3: rpm10K + 4: rpm15K + 5: rpmSsd + - name: cpqSasPhyDrvOsName + oid: 1.3.6.1.4.1.232.5.5.2.1.1.13 + type: DisplayString + help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvPlacement + oid: 1.3.6.1.4.1.232.5.5.2.1.1.14 + type: gauge + help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: internal + 3: external + - name: cpqSasPhyDrvHotPlug + oid: 1.3.6.1.4.1.232.5.5.2.1.1.15 + type: gauge + help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: hotPlug + 3: nonHotPlug + - name: cpqSasPhyDrvType + oid: 1.3.6.1.4.1.232.5.5.2.1.1.16 + type: gauge + help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: sas + 3: sata + - name: cpqSasPhyDrvSasAddress + oid: 1.3.6.1.4.1.232.5.5.2.1.1.17 + type: DisplayString + help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvMediaType + oid: 1.3.6.1.4.1.232.5.5.2.1.1.18 + type: gauge + help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: rotatingPlatters + 3: solidState + - name: cpqSasPhyDrvSSDWearStatus + oid: 1.3.6.1.4.1.232.5.5.2.1.1.19 + type: gauge + help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: fiftySixDayThreshold + 4: fivePercentThreshold + 5: twoPercentThreshold + 6: ssdWearOut + - name: cpqSasPhyDrvPowerOnHours + oid: 1.3.6.1.4.1.232.5.5.2.1.1.20 + type: counter + help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSSDPercntEndrnceUsed + oid: 1.3.6.1.4.1.232.5.5.2.1.1.21 + type: gauge + help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSSDEstTimeRemainingHours + oid: 1.3.6.1.4.1.232.5.5.2.1.1.22 + type: counter + help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvAuthenticationStatus + oid: 1.3.6.1.4.1.232.5.5.2.1.1.23 + type: gauge + help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + enum_values: + 1: other + 2: notSupported + 3: authenticationFailed + 4: authenticationPassed + - name: cpqSasPhyDrvSmartCarrierAppFWRev + oid: 1.3.6.1.4.1.232.5.5.2.1.1.24 + type: gauge + help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSmartCarrierBootldrFWRev + oid: 1.3.6.1.4.1.232.5.5.2.1.1.25 + type: gauge + help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvCurrTemperature + oid: 1.3.6.1.4.1.232.5.5.2.1.1.26 + type: gauge + help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvTemperatureThreshold + oid: 1.3.6.1.4.1.232.5.5.2.1.1.27 + type: gauge + help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSsBoxModel + oid: 1.3.6.1.4.1.232.5.5.2.1.1.28 + type: DisplayString + help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSsBoxFwRev + oid: 1.3.6.1.4.1.232.5.5.2.1.1.29 + type: DisplayString + help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSsBoxVendor + oid: 1.3.6.1.4.1.232.5.5.2.1.1.30 + type: DisplayString + help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name - 1.3.6.1.4.1.232.5.5.2.1.1.30 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasPhyDrvSsBoxSerialNumber + oid: 1.3.6.1.4.1.232.5.5.2.1.1.31 + type: DisplayString + help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31 + indexes: + - labelname: cpqSasPhyDrvHbaIndex + type: gauge + - labelname: cpqSasPhyDrvIndex + type: gauge + - name: cpqSasLogDrvHbaIndex + oid: 1.3.6.1.4.1.232.5.5.3.1.1.1 + type: gauge + help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvIndex + oid: 1.3.6.1.4.1.232.5.5.3.1.1.2 + type: gauge + help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvRaidLevel + oid: 1.3.6.1.4.1.232.5.5.3.1.1.3 + type: gauge + help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + enum_values: + 1: other + 2: raid0 + 3: raid1 + 4: raid0plus1 + 5: raid5 + 6: raid15 + 7: volume + - name: cpqSasLogDrvStatus + oid: 1.3.6.1.4.1.232.5.5.3.1.1.4 + type: gauge + help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: rebuilding + 5: failed + 6: offline + - name: cpqSasLogDrvCondition + oid: 1.3.6.1.4.1.232.5.5.3.1.1.5 + type: gauge + help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqSasLogDrvRebuildingDisk + oid: 1.3.6.1.4.1.232.5.5.3.1.1.6 + type: gauge + help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvCapacity + oid: 1.3.6.1.4.1.232.5.5.3.1.1.7 + type: gauge + help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvStripeSize + oid: 1.3.6.1.4.1.232.5.5.3.1.1.8 + type: gauge + help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvPhyDrvIds + oid: 1.3.6.1.4.1.232.5.5.3.1.1.9 + type: OctetString + help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvSpareIds + oid: 1.3.6.1.4.1.232.5.5.3.1.1.10 + type: OctetString + help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvOsName + oid: 1.3.6.1.4.1.232.5.5.3.1.1.11 + type: DisplayString + help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasLogDrvRebuildingPercent + oid: 1.3.6.1.4.1.232.5.5.3.1.1.12 + type: gauge + help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12 + indexes: + - labelname: cpqSasLogDrvHbaIndex + type: gauge + - labelname: cpqSasLogDrvIndex + type: gauge + - name: cpqSasTapeDrvHbaIndex + oid: 1.3.6.1.4.1.232.5.5.4.1.1.1 + type: gauge + help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvIndex + oid: 1.3.6.1.4.1.232.5.5.4.1.1.2 + type: gauge + help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvLocationString + oid: 1.3.6.1.4.1.232.5.5.4.1.1.3 + type: DisplayString + help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvName + oid: 1.3.6.1.4.1.232.5.5.4.1.1.4 + type: DisplayString + help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvStatus + oid: 1.3.6.1.4.1.232.5.5.4.1.1.5 + type: gauge + help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: offline + - name: cpqSasTapeDrvCondition + oid: 1.3.6.1.4.1.232.5.5.4.1.1.6 + type: gauge + help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqSasTapeDrvFWRev + oid: 1.3.6.1.4.1.232.5.5.4.1.1.7 + type: DisplayString + help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvSerialNumber + oid: 1.3.6.1.4.1.232.5.5.4.1.1.8 + type: DisplayString + help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqSasTapeDrvSasAddress + oid: 1.3.6.1.4.1.232.5.5.4.1.1.9 + type: DisplayString + help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9 + indexes: + - labelname: cpqSasTapeDrvHbaIndex + type: gauge + - labelname: cpqSasTapeDrvIndex + type: gauge + - name: cpqHeResMem2ModuleSize + oid: 1.3.6.1.4.1.232.6.2.14.13.1.6 + type: gauge + help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6 + indexes: + - labelname: cpqHeResMem2Module + type: gauge + - name: cpqHePowerMeterSupport + oid: 1.3.6.1.4.1.232.6.2.15.1 + type: gauge + help: This value specifies whether Power Meter is supported by this Server - 1.3.6.1.4.1.232.6.2.15.1 + enum_values: + 1: other + 2: supported + 3: unsupported + - name: cpqHePowerMeterStatus + oid: 1.3.6.1.4.1.232.6.2.15.2 + type: gauge + help: This value specifies whether Power Meter reading is supported by this Server - 1.3.6.1.4.1.232.6.2.15.2 + enum_values: + 1: other + 2: present + 3: absent + - name: cpqHePowerMeterCurrReading + oid: 1.3.6.1.4.1.232.6.2.15.3 + type: gauge + help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3 + - name: cpqHePowerMeterPrevReading + oid: 1.3.6.1.4.1.232.6.2.15.4 + type: gauge + help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4 + - name: cpqHeHWBiosCondition + oid: 1.3.6.1.4.1.232.6.2.16.1 + type: gauge + help: This value indicates an error has been detected during Pre-OS Test (POST) or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeSysBackupBatteryCondition + oid: 1.3.6.1.4.1.232.6.2.17.1 + type: gauge + help: This value specifies the overall condition of the battery backup sub-system. - 1.3.6.1.4.1.232.6.2.17.1 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeSysBatteryChassis + oid: 1.3.6.1.4.1.232.6.2.17.2.1.1 + type: gauge + help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatteryIndex + oid: 1.3.6.1.4.1.232.6.2.17.2.1.2 + type: gauge + help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatteryPresent + oid: 1.3.6.1.4.1.232.6.2.17.2.1.3 + type: gauge + help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + enum_values: + 1: other + 2: absent + 3: present + - name: cpqHeSysBatteryCondition + oid: 1.3.6.1.4.1.232.6.2.17.2.1.4 + type: gauge + help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeSysBatteryStatus + oid: 1.3.6.1.4.1.232.6.2.17.2.1.5 + type: gauge + help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + enum_values: + 1: noError + 2: generalFailure + 3: shutdownHighResistance + 4: shutdownLowVoltage + 5: shutdownShortCircuit + 6: shutdownChargeTimeout + 7: shutdownOverTemperature + 8: shutdownDischargeMinVoltage + 9: shutdownDischargeCurrent + 10: shutdownLoadCountHigh + 11: shutdownEnablePin + 12: shutdownOverCurrent + 13: shutdownPermanentFailure + 14: shutdownBackupTimeExceeded + 15: predictiveFailure + - name: cpqHeSysBatteryCapacityMaximum + oid: 1.3.6.1.4.1.232.6.2.17.2.1.6 + type: gauge + help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatteryProductName + oid: 1.3.6.1.4.1.232.6.2.17.2.1.7 + type: DisplayString + help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatteryModel + oid: 1.3.6.1.4.1.232.6.2.17.2.1.8 + type: DisplayString + help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatterySerialNumber + oid: 1.3.6.1.4.1.232.6.2.17.2.1.9 + type: DisplayString + help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatteryFirmwareRev + oid: 1.3.6.1.4.1.232.6.2.17.2.1.10 + type: DisplayString + help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeSysBatterySparePartNum + oid: 1.3.6.1.4.1.232.6.2.17.2.1.11 + type: DisplayString + help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11 + indexes: + - labelname: cpqHeSysBatteryChassis + type: gauge + - labelname: cpqHeSysBatteryIndex + type: gauge + - name: cpqHeTemperatureChassis + oid: 1.3.6.1.4.1.232.6.2.6.8.1.1 + type: gauge + help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + - name: cpqHeTemperatureIndex + oid: 1.3.6.1.4.1.232.6.2.6.8.1.2 + type: gauge + help: A number that uniquely specifies this temperature sensor description. - 1.3.6.1.4.1.232.6.2.6.8.1.2 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + - name: cpqHeTemperatureLocale + oid: 1.3.6.1.4.1.232.6.2.6.8.1.3 + type: gauge + help: This specifies the location of the temperature sensor present in the system. - 1.3.6.1.4.1.232.6.2.6.8.1.3 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + enum_values: + 1: other + 2: unknown + 3: system + 4: systemBoard + 5: ioBoard + 6: cpu + 7: memory + 8: storage + 9: removableMedia + 10: powerSupply + 11: ambient + 12: chassis + 13: bridgeCard + - name: cpqHeTemperatureCelsius + oid: 1.3.6.1.4.1.232.6.2.6.8.1.4 + type: gauge + help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + - name: cpqHeTemperatureThreshold + oid: 1.3.6.1.4.1.232.6.2.6.8.1.5 + type: gauge + help: This is the shutdown threshold temperature sensor setting in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.5 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + - name: cpqHeTemperatureCondition + oid: 1.3.6.1.4.1.232.6.2.6.8.1.6 + type: gauge + help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeTemperatureThresholdType + oid: 1.3.6.1.4.1.232.6.2.6.8.1.7 + type: gauge + help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + enum_values: + 1: other + 5: blowout + 9: caution + 15: critical + 16: noreaction + - name: cpqHeTemperatureHwLocation + oid: 1.3.6.1.4.1.232.6.2.6.8.1.8 + type: DisplayString + help: A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8 + indexes: + - labelname: cpqHeTemperatureChassis + type: gauge + - labelname: cpqHeTemperatureIndex + type: gauge + - name: cpqHeFltTolPwrSupplyCondition + oid: 1.3.6.1.4.1.232.6.2.9.1 + type: gauge + help: This value specifies the overall condition of the fault tolerant power supply sub-system. - 1.3.6.1.4.1.232.6.2.9.1 + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeFltTolPwrSupplyStatus + oid: 1.3.6.1.4.1.232.6.2.9.2 + type: gauge + help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2 + enum_values: + 1: other + 2: notSupported + 3: notInstalled + 4: installed + - name: cpqHeFltTolPowerSupplyChassis + oid: 1.3.6.1.4.1.232.6.2.9.3.1.1 + type: gauge + help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyBay + oid: 1.3.6.1.4.1.232.6.2.9.3.1.2 + type: gauge + help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyPresent + oid: 1.3.6.1.4.1.232.6.2.9.3.1.3 + type: gauge + help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: other + 2: absent + 3: present + - name: cpqHeFltTolPowerSupplyCondition + oid: 1.3.6.1.4.1.232.6.2.9.3.1.4 + type: gauge + help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: other + 2: ok + 3: degraded + 4: failed + - name: cpqHeFltTolPowerSupplyStatus + oid: 1.3.6.1.4.1.232.6.2.9.3.1.5 + type: gauge + help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: noError + 2: generalFailure + 3: bistFailure + 4: fanFailure + 5: tempFailure + 6: interlockOpen + 7: epromFailed + 8: vrefFailed + 9: dacFailed + 10: ramTestFailed + 11: voltageChannelFailed + 12: orringdiodeFailed + 13: brownOut + 14: giveupOnStartup + 15: nvramInvalid + 16: calibrationTableInvalid + 17: noPowerInput + - name: cpqHeFltTolPowerSupplyMainVoltage + oid: 1.3.6.1.4.1.232.6.2.9.3.1.6 + type: gauge + help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyCapacityUsed + oid: 1.3.6.1.4.1.232.6.2.9.3.1.7 + type: gauge + help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyCapacityMaximum + oid: 1.3.6.1.4.1.232.6.2.9.3.1.8 + type: gauge + help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyRedundant + oid: 1.3.6.1.4.1.232.6.2.9.3.1.9 + type: gauge + help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: other + 2: notRedundant + 3: redundant + - name: cpqHeFltTolPowerSupplyModel + oid: 1.3.6.1.4.1.232.6.2.9.3.1.10 + type: DisplayString + help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplySerialNumber + oid: 1.3.6.1.4.1.232.6.2.9.3.1.11 + type: DisplayString + help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyAutoRev + oid: 1.3.6.1.4.1.232.6.2.9.3.1.12 + type: OctetString + help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyHotPlug + oid: 1.3.6.1.4.1.232.6.2.9.3.1.13 + type: gauge + help: This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: other + 2: nonHotPluggable + 3: hotPluggable + - name: cpqHeFltTolPowerSupplyFirmwareRev + oid: 1.3.6.1.4.1.232.6.2.9.3.1.14 + type: DisplayString + help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyHwLocation + oid: 1.3.6.1.4.1.232.6.2.9.3.1.15 + type: DisplayString + help: A text description of the hardware location, on complex multi SBB hardware only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplySparePartNum + oid: 1.3.6.1.4.1.232.6.2.9.3.1.16 + type: DisplayString + help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyRedundantPartner + oid: 1.3.6.1.4.1.232.6.2.9.3.1.17 + type: gauge + help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + - name: cpqHeFltTolPowerSupplyErrorCondition + oid: 1.3.6.1.4.1.232.6.2.9.3.1.18 + type: gauge + help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18 + indexes: + - labelname: cpqHeFltTolPowerSupplyChassis + type: gauge + - labelname: cpqHeFltTolPowerSupplyBay + type: gauge + enum_values: + 1: noError + 2: generalFailure + 3: overvoltage + 4: overcurrent + 5: overtemperature + 6: powerinputloss + 7: fanfailure + 8: vinhighwarning + 9: vinlowwarning + 10: vouthighwarning + 11: voutlowwarning + 12: inlettemphighwarning + 13: iinternaltemphighwarning + 14: vauxhighwarning + 15: vauxlowwarning + 16: powersupplymismatch + 17: goodinstandby + - name: cpqSm2CntlrRomDate + oid: 1.3.6.1.4.1.232.9.2.2.1 + type: DisplayString + help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1 + - name: cpqSm2CntlrRomRevision + oid: 1.3.6.1.4.1.232.9.2.2.2 + type: DisplayString + help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2 + - name: cpqSm2CntlrVideoStatus + oid: 1.3.6.1.4.1.232.9.2.2.3 + type: gauge + help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3 + enum_values: + 1: other + 2: enabled + 3: disabled + - name: cpqSm2CntlrBatteryEnabled + oid: 1.3.6.1.4.1.232.9.2.2.4 + type: gauge + help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4 + enum_values: + 1: other + 2: enabled + 3: disabled + 4: noBattery + - name: cpqSm2CntlrBatteryStatus + oid: 1.3.6.1.4.1.232.9.2.2.5 + type: gauge + help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5 + enum_values: + 1: other + 2: batteryOk + 3: batteryFailed + 4: batteryDisconnected + - name: cpqSm2CntlrBatteryPercentCharged + oid: 1.3.6.1.4.1.232.9.2.2.6 + type: gauge + help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6 + - name: cpqSm2CntlrAlertStatus + oid: 1.3.6.1.4.1.232.9.2.2.7 + type: gauge + help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7 + enum_values: + 1: other + 2: enabled + 3: disabled + - name: cpqSm2CntlrPendingAlerts + oid: 1.3.6.1.4.1.232.9.2.2.8 + type: gauge + help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8 + enum_values: + 1: other + 2: noAlertsPending + 3: alertsPending + 4: clearPendingAlerts + - name: cpqSm2CntlrSelfTestErrors + oid: 1.3.6.1.4.1.232.9.2.2.9 + type: gauge + help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9 + - name: cpqSm2CntlrAgentLocation + oid: 1.3.6.1.4.1.232.9.2.2.10 + type: gauge + help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10 + enum_values: + 1: hostOsAgent + 2: firmwareAgent + 3: remoteInsightPciFirmwareAgent + 4: enclosureFirmwareAgent + - name: cpqSm2CntlrLastDataUpdate + oid: 1.3.6.1.4.1.232.9.2.2.11 + type: OctetString + help: The date and time that the Remote Insight/ Integrated Lights-Out offline data was last updated - 1.3.6.1.4.1.232.9.2.2.11 + - name: cpqSm2CntlrDataStatus + oid: 1.3.6.1.4.1.232.9.2.2.12 + type: gauge + help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12 + enum_values: + 1: other + 2: noData + 3: onlineData + 4: offlineData + - name: cpqSm2CntlrColdReboot + oid: 1.3.6.1.4.1.232.9.2.2.13 + type: gauge + help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following values are defined: notAvailable(1) Cold reboot of the system is not available - 1.3.6.1.4.1.232.9.2.2.13' + enum_values: + 1: notAvailable + 2: available + 3: doColdReboot + - name: cpqSm2CntlrBadLoginAttemptsThresh + oid: 1.3.6.1.4.1.232.9.2.2.14 + type: gauge + help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14 + - name: cpqSm2CntlrBoardSerialNumber + oid: 1.3.6.1.4.1.232.9.2.2.15 + type: DisplayString + help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15 + - name: cpqSm2CntlrRemoteSessionStatus + oid: 1.3.6.1.4.1.232.9.2.2.16 + type: gauge + help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16 + enum_values: + 1: other + 2: active + 3: inactive + - name: cpqSm2CntlrInterfaceStatus + oid: 1.3.6.1.4.1.232.9.2.2.17 + type: gauge + help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17 + enum_values: + 1: other + 2: ok + 3: notResponding + - name: cpqSm2CntlrSystemId + oid: 1.3.6.1.4.1.232.9.2.2.18 + type: DisplayString + help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18 + - name: cpqSm2CntlrKeyboardCableStatus + oid: 1.3.6.1.4.1.232.9.2.2.19 + type: gauge + help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19 + enum_values: + 1: other + 2: connected + 3: disconnected + - name: cpqSm2ServerIpAddress + oid: 1.3.6.1.4.1.232.9.2.2.20 + type: InetAddressIPv4 + help: The IP address for this servers connection to the Remote Insight/ Integrated Lights-Out - 1.3.6.1.4.1.232.9.2.2.20 + - name: cpqSm2CntlrModel + oid: 1.3.6.1.4.1.232.9.2.2.21 + type: gauge + help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21 + enum_values: + 1: other + 2: eisaRemoteInsightBoard + 3: pciRemoteInsightBoard + 4: pciLightsOutRemoteInsightBoard + 5: pciIntegratedLightsOutRemoteInsight + 6: pciLightsOutRemoteInsightBoardII + 7: pciIntegratedLightsOutRemoteInsight2 + 8: pciLightsOut100series + 9: pciIntegratedLightsOutRemoteInsight3 + 10: pciIntegratedLightsOutRemoteInsight4 + 11: pciIntegratedLightsOutRemoteInsight5 + - name: cpqSm2CntlrSelfTestErrorMask + oid: 1.3.6.1.4.1.232.9.2.2.22 + type: gauge + help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22 + - name: cpqSm2CntlrMouseCableStatus + oid: 1.3.6.1.4.1.232.9.2.2.23 + type: gauge + help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23 + enum_values: + 1: other + 2: connected + 3: disconnected + - name: cpqSm2CntlrVirtualPowerCableStatus + oid: 1.3.6.1.4.1.232.9.2.2.24 + type: gauge + help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24 + enum_values: + 1: other + 2: connected + 3: disconnected + 4: notApplicable + - name: cpqSm2CntlrExternalPowerCableStatus + oid: 1.3.6.1.4.1.232.9.2.2.25 + type: gauge + help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25 + enum_values: + 1: other + 2: externallyConnected + 3: disconnected + 4: internallyConnected + 5: externallyAndInternallyConnected + 6: notApplicable + - name: cpqSm2CntlrHostGUID + oid: 1.3.6.1.4.1.232.9.2.2.26 + type: OctetString + help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26 + - name: cpqSm2CntlriLOSecurityOverrideSwitchState + oid: 1.3.6.1.4.1.232.9.2.2.27 + type: gauge + help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27 + enum_values: + 1: notSupported + 2: set + 3: notSet + - name: cpqSm2CntlrHardwareVer + oid: 1.3.6.1.4.1.232.9.2.2.28 + type: gauge + help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28 + - name: cpqSm2CntlrAction + oid: 1.3.6.1.4.1.232.9.2.2.29 + type: gauge + help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29 + - name: cpqSm2CntlrLicenseActive + oid: 1.3.6.1.4.1.232.9.2.2.30 + type: gauge + help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30 + enum_values: + 1: none + 2: iloAdvanced + 3: iloLight + 4: iloAdvancedBlade + 5: iloStandard + 6: iloEssentials + 7: iloScaleOut + 8: iloAdvancedPremiumSecurity + - name: cpqSm2CntlrLicenseKey + oid: 1.3.6.1.4.1.232.9.2.2.31 + type: DisplayString + help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31 + - name: cpqSm2CntlrServerPowerState + oid: 1.3.6.1.4.1.232.9.2.2.32 + type: gauge + help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32 + enum_values: + 1: unknown + 2: poweredOff + 3: poweredOn + 4: insufficientPowerOrPowerOnDenied + - name: cpqSm2CntlrSysAutoShutdownCause + oid: 1.3.6.1.4.1.232.9.2.2.33 + type: gauge + help: Indicate the reason for triggering system auto shutdown or cancelling auto shutdown. - 1.3.6.1.4.1.232.9.2.2.33 + enum_values: + 1: fanFailure + 2: overheatCondition + 3: vrmFailure + 4: powerSupplyFailure + 5: systemRunningOnBatteryBackupUnit + 129: aborted + 130: fanFailureAborted + 131: overheatAborted + 132: vrmFailureAborted + 133: softPowerDown + 134: softwareAutomaticServerRecovery + 135: powerSupplyFailureAborted + - name: cpqSm2CntlrSecurityState + oid: 1.3.6.1.4.1.232.9.2.2.34 + type: gauge + help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34 + enum_values: + 1: factory + 2: wipe + 3: production + 4: highSecurity + 5: fips + 6: cnsa + - name: cpqSm2WDTimerType + oid: 1.3.6.1.4.1.232.9.2.2.35 + type: gauge + help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35 + enum_values: + 1: unknown + 2: ipmi + - name: cpqSm2WDTimerTimeoutDetails + oid: 1.3.6.1.4.1.232.9.2.2.36 + type: DisplayString + help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36 + - name: cpqSm2CntlrOverallSecStatus + oid: 1.3.6.1.4.1.232.9.2.2.37 + type: gauge + help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37 + enum_values: + 1: Ok + 2: Risk + 3: Ignored diff --git a/k8s/monitoring/prometheus-scrape-configs/external-node-exporters.yaml b/k8s/monitoring/prometheus-scrape-configs/external-node-exporters.yaml new file mode 100644 index 0000000..82c14d8 --- /dev/null +++ b/k8s/monitoring/prometheus-scrape-configs/external-node-exporters.yaml @@ -0,0 +1,25 @@ +apiVersion: v1 +kind: ConfigMap +metadata: + name: external-node-exporters + namespace: monitoring + +data: + prometheus-additional.yaml: | + - job_name: 'external-node-exporters' + + static_configs: + - targets: + - 10.0.1.2:9100 + - 10.0.1.3:9100 + - 10.0.1.4:9100 + - 10.0.1.6:9100 + - 10.0.1.7:9100 + - 10.0.1.8:9100 + - 10.0.1.9:9100 + - 10.0.1.10:9100 + - 10.0.1.11:9100 + - 10.0.1.12:9100 + - 10.0.1.20:9100 + - 10.0.2.5:9100 + - 10.0.3.2:9100 diff --git a/k8s/monitoring/prometheus-scrape-configs/ipmi-values.yaml b/k8s/monitoring/prometheus-scrape-configs/ipmi-values.yaml new file mode 100644 index 0000000..565973f --- /dev/null +++ b/k8s/monitoring/prometheus-scrape-configs/ipmi-values.yaml @@ -0,0 +1,12 @@ +config: + modules: + default: + user: "Admin" + pass: "Richa1000" + privilege: "administrator" + driver: "LAN_2_0" + + collectors: + - ipmi + - chassis + - bmc diff --git a/k8s/monitoring/prometheus-scrape-configs/prometheus-values.yaml b/k8s/monitoring/prometheus-scrape-configs/prometheus-values.yaml new file mode 100644 index 0000000..c3323dd --- /dev/null +++ b/k8s/monitoring/prometheus-scrape-configs/prometheus-values.yaml @@ -0,0 +1,415 @@ +prometheus: + prometheusSpec: + retention: 7d + resources: + requests: + memory: 512Mi + limits: + memory: 1Gi + additionalScrapeConfigs: + + - job_name: 'blackbox-icmp' + + metrics_path: /probe + + params: + module: [icmp] + + static_configs: + - targets: ["10.0.0.1"] + labels: + hostname: router + device_type: router + + - targets: ["10.0.0.123"] + labels: + hostname: switch + device_type: switch + + - targets: ["10.0.0.232"] + labels: + hostname: ap-loznice + device_type: ap + + - targets: ["10.0.0.233"] + labels: + hostname: ap-det-pokoj + device_type: ap + + - targets: ["10.0.0.13"] + labels: + hostname: konica-minolta-bizhub-227 + device_type: printer + + - targets: ["10.0.0.152"] + labels: + hostname: hp-officejet-pro-6830 + device_type: printer + + - targets: ["10.0.2.2"] + labels: + hostname: main-nas + device_type: nas + + - targets: ["10.0.2.12"] + labels: + hostname: backup-nas + device_type: nas + + - targets: ["10.0.2.6"] + labels: + hostname: nas-raid-card + device_type: storage-controller + + - targets: ["10.0.2.4"] + labels: + hostname: mac-mini + device_type: mac + + - targets: ["10.0.0.139"] + labels: + hostname: klipper-rpi4b + device_type: raspberry-pi + + - targets: ["10.0.2.130"] + labels: + hostname: r720-overlord-idrac + device_type: idrac + + - targets: ["10.0.2.131"] + labels: + hostname: r620-idrac + device_type: idrac + + - targets: ["10.0.2.132"] + labels: + hostname: r720-proxmox-idrac + device_type: idrac + + - targets: ["10.0.2.133"] + labels: + hostname: hp-dl360p-g8-ilo + device_type: ilo + + - targets: ["10.0.2.134"] + labels: + hostname: dell-precision-rack-7910-idrac + device_type: idrac + + - targets: ["10.0.2.136"] + labels: + hostname: r420-idrac + device_type: idrac + + - targets: ["10.0.2.137"] + labels: + hostname: t620-idrac + device_type: idrac + + - targets: ["10.0.1.2"] + labels: + hostname: plexisklo + device_type: lxc + + - targets: ["10.0.1.3"] + labels: + hostname: synch + device_type: lxc + + - targets: ["10.0.1.4"] + labels: + hostname: graylog + device_type: vm + + - targets: ["10.0.1.6"] + labels: + hostname: kozel-tajne + device_type: lxc + + - targets: ["10.0.1.7"] + labels: + hostname: kozel-web + device_type: lxc + + - targets: ["10.0.1.8"] + labels: + hostname: qbittorrent + device_type: lxc + + - targets: ["10.0.1.9"] + labels: + hostname: docker + device_type: lxc + + - targets: ["10.0.1.10"] + labels: + hostname: pihole + device_type: lxc + + - targets: ["10.0.1.11"] + labels: + hostname: gitea + device_type: lxc + + - targets: ["10.0.1.12"] + labels: + hostname: mariadb + device_type: lxc + + - targets: ["10.0.1.20"] + labels: + hostname: zabbix + device_type: vm + + - targets: ["10.0.2.5"] + labels: + hostname: proxmox + device_type: server + + - targets: ["10.0.3.2"] + labels: + hostname: mc-servers + device_type: server + + relabel_configs: + + - source_labels: [__address__] + target_label: __param_target + + - source_labels: [__param_target] + target_label: instance + + - target_label: __address__ + replacement: blackbox-exporter-prometheus-blackbox-exporter.monitoring.svc.cluster.local:9115 + + - job_name: external-node-exporters + + static_configs: + - targets: + - 10.0.1.2:9100 + labels: + hostname: plexisklo + + - targets: + - 10.0.1.3:9100 + labels: + hostname: synch + + - targets: + - 10.0.1.4:9100 + labels: + hostname: graylog + + - targets: + - 10.0.1.6:9100 + labels: + hostname: kozel-tajne + + - targets: + - 10.0.1.7:9100 + labels: + hostname: kozel-web + + - targets: + - 10.0.1.8:9100 + labels: + hostname: qbittorrent + + - targets: + - 10.0.1.9:9100 + labels: + hostname: docker + + - targets: + - 10.0.1.10:9100 + labels: + hostname: pihloe + + - targets: + - 10.0.1.11:9100 + labels: + hostname: gitea + + - targets: + - 10.0.1.12:9100 + labels: + hostname: mariadb + + - targets: + - 10.0.1.20:9100 + labels: + hostname: zabbix + + - targets: + - 10.0.2.5:9100 + labels: + hostname: proxmox + + - targets: + - 10.0.3.2:9100 + labels: + hostname: mc-servers + + - job_name: 'snmp-if-mib' + scrape_interval: 4m + scrape_timeout: 180s + metrics_path: /snmp + params: + module: [if_mib] + auth: [public_v2] + static_configs: + - targets: + - 10.0.0.1 # Router + - 10.0.0.123 # Switch + - 10.0.0.233 # AP-Dět.Pkoj + - 10.0.0.232 # AP-Ložnice + - 10.0.2.12 # Backup-NAS + - 10.0.2.2 # Main NAS + - 10.0.0.13 # Konica Minolta + relabel_configs: + - source_labels: [__address__] + target_label: __param_target + - source_labels: [__param_target] + target_label: instance + - target_label: __address__ + replacement: snmp-exporter-manual.monitoring.svc.cluster.local:9116 + +# - job_name: 'snmp-mib' +# scrape_interval: 4m +# scrape_timeout: 180s +# metrics_path: /snmp +# params: +# module: [mikrotik] +# auth: [public_v2] +# static_configs: +# - targets: +# - 10.0.0.1 # Router +# - 10.0.0.123 # Switch +# - 10.0.0.233 # AP-Dět.Pkoj +# - 10.0.0.232 # AP-Ložnice +# relabel_configs: +# - source_labels: [__address__] +# target_label: __param_target +# - source_labels: [__param_target] +# target_label: instance +# - target_label: __address__ +# replacement: snmp-exporter-manual.monitoring.svc.cluster.local:9116 + +# - job_name: 'snmp-host-resources' +# scrape_interval: 4m +# scrape_timeout: 180s +# metrics_path: /snmp +# params: +# module: [resources_hst] +# auth: [public_v2] +# static_configs: +# - targets: +# - 10.0.0.1 # Router +# - 10.0.0.123 # Switch +# - 10.0.0.233 # AP-Dět.Pkoj +# - 10.0.0.232 # AP-Ložnice +# - 10.0.2.12 # Backup-NAS +# - 10.0.2.2 # Main NAS +# - 10.0.2.6 # NAS RAID karta +# - 10.0.0.13 # Konica Minolta +# relabel_configs: +# - source_labels: [__address__] +# target_label: __param_target +# - source_labels: [__param_target] +# target_label: instance +# - target_label: __address__ +# replacement: snmp-exporter-manual.monitoring.svc.cluster.local:9116 + +# - job_name: 'snmp-dell-idrac' +# scrape_interval: 4m +# scrape_timeout: 180s +# metrics_path: /snmp +# params: +# module: [dell_rac] +# auth: [public_v2] +# static_configs: +# - targets: +# - 10.0.2.130 +# - 10.0.2.131 +# - 10.0.2.132 +# - 10.0.2.134 +# - 10.0.2.136 +# - 10.0.2.137 +# relabel_configs: +# - source_labels: [__address__] +# target_label: __param_target +# - source_labels: [__param_target] +# target_label: instance +# - target_label: __address__ +# replacement: snmp-exporter-manual.monitoring.svc.cluster.local:9116 + +# - job_name: 'snmp-hpe-ilo' +# scrape_interval: 4m +# scrape_timeout: 180s +# metrics_path: /snmp +# params: +# module: [hpe] +# auth: [public_v2] +# static_configs: +# - targets: +# - 10.0.2.133 +# relabel_configs: +# - source_labels: [__address__] +# target_label: __param_target +# - source_labels: [__param_target] +# target_label: instance +# - target_label: __address__ +# replacement: snmp-exporter-manual.monitoring.svc.cluster.local:9116 + + - job_name: 'proxmox' + metrics_path: /pve + params: + module: [default] + cluster: ['1'] + node: ['1'] + static_configs: + - targets: + - 10.0.2.5 + relabel_configs: + - source_labels: [__address__] + target_label: __param_target + - source_labels: [__param_target] + target_label: instance + - target_label: __address__ + replacement: pve-exporter.monitoring.svc.cluster.local:9221 + + - job_name: 'ipmi-dell-ilo' + metrics_path: /ipmi + params: + module: [default] + static_configs: + - targets: + - 10.0.2.130 + - 10.0.2.131 + - 10.0.2.132 + - 10.0.2.133 + - 10.0.2.134 + - 10.0.2.136 + - 10.0.2.137 + relabel_configs: + - source_labels: [__address__] + target_label: __param_target + - source_labels: [__param_target] + target_label: instance + - target_label: __address__ + replacement: ipmi-exporter-prometheus-ipmi-exporter.monitoring.svc.cluster.local:9290 + +grafana: + resources: + requests: + memory: 128Mi + limits: + memory: 256Mi + +alertmanager: + alertmanagerSpec: + resources: + requests: + memory: 128Mi + limits: + memory: 256Mi